![Trust TC Series Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/trust/tc-series/tc-series_manual_1176650013.webp)
a
b
c
d
T 1
e
When T1-Ts<
Δ
T -2
℃
, the compressor will stop,
when T1
—
Ts >
Δ
T -0.5
℃,
the compressor will
be activated.
Δ
T is the programmed parameter of
temperature compensation.
When the AC run in mute mode, the
compressor will run with low frequency.
When the current is more than setting value,
the current protection function will be activated,
and the compressor will stop.
The outdoor unit will be run at different fan
speed according to T4.
For different outdoor units, the fan speeds are
different.
High
Low
Setting fan
speed
Actual fan speed
H+(H+=H+G)
A
H
(
=H
)
B
C
M+(M+=M+Z)
D
M(M=M)
E
F
L+(L+=L+D)
G
L(L=L)
H
I
T1-Td
℃
(
°
F)
L
L-(L-=L-D)
H
H-
(
H-=H-G)
M
M-(M-=M-Z)
The auto fan acts as below rules:
a
b
c
d
T 1
e
Resume
Off
Decrease
Hold
Increase
3
.4 Operation Modes and Functions
3
.4.1 Fan mode
(
1) Outdoor fan and compressor stop.
(2) Temperature setting function is disabled,
and no setting temperature is displayed.
(3) Indoor fan can be set to
high/med/low/auto.
(4) The louver operates same as in cooling
mode.
(5) Auto fan:
3
.4.2.3 Indoor fan running rules
In cooling mode, indoor fan runs all the time
and the speed can be selected as high,
medium, low and auto.
The indoor fan is controlled as below:
3
.4.2 Cooling Mode
3
.4.2.1 Compressor running rules
3
.4.2.2 Outdoor fan running rules
3
.4.2.4 Condenser temperature protection
T3
11