10-EN
EN-11
2.2 User controls and indicators
Figure 3 User controls and indicators
Figure 4 Control panel
1
Contrast
a
Power ON/OFF
2
Brightness
b
Degaussing
3
Horizontal size
c
Select
4
Horizontal phase
d+e
Increase "+", Decrease "-", Recall "+" and "-
"
5
Vertical size
6
Vertical centering
7
Pincushion/Barrel
8
Key stone
The user control parameters are selected in sequence by pressing the SELECT button in the front
panel, the selected parameter is indicated by the illuminated LED(s), the function is described
below:
1
Contrast
2
Brightness
3
Horizontal Size
4
Horizontal Phase
5
Vertical Size
6
Vertical Centring
7
Pincushion/Barrel
8
Trapezoid; then repeat from sequence 1.
Each parameter can be adjusted with the "+" and "-" buttons.
When the control value reaches the maximum value (either positive or negative end), the LED
will flash, indicating that no more adjustment value increase/decrease is possible.
The manual "Degaussing" function enables the user to clear the picture impurity caused by
monitor position/orientation change.
The "Recall" function is activated by pressing the "+" and "-" buttons simultaneously.
There are a total of 16 factory preset modes and 14 user modes allowed. For the factory preset
modes, all parameters have been set and stored permanently in the memory, according to the
standard VESA timing. The factory preset data can be "recalled" to initial values any time during
operation even if they have been modified by the user through external user controls.
User modes are left to users for the special timings they may want. All the user adjustments are
stored in the memory automatically after the adjustment is finished, these values remain stored
after the power is turned off.