13
Chapter 6:
Troubleshooting
If the UPS does not function properly, please check the
troubleshooting chart below. When the unit has to be returned
to the dealer for service, write down the information below:
- Model number and serial number
- Date of purchase
- Full description of the problem
Finally, pack the UPS in the original carton.
Troubleshooting Chart
Problem
Possible Cause
Action
UPS is not switched
on
LED is not lit
1 on/off/test/silence
button not pressed or
pressed too short
2 battery voltage less
than 10V
3 PCB failure
4 load less than 15W
in battery mode
1 press the on/off/
test/silence button for
more than 1 sec.
2 recharge the UPS
for at least 4 hours
3 PCB needs to be
replaced, call for
service
4 normal condition
UPS is always in
battery mode
1 power cord is loose
2 AC fuse has burned
out
3 line voltage is too
high, too low or has
blacked out
4 PCB failure
1 reconnect it
2 replace the AC fuse
3 normal condition
4 PCB needs to be
replaced, call for
service
Back-up time is too
short
1 battery is not fully
charged
2 PCB failure
1 recharge the UPS
for at least 4 hours
2 PCB needs to be
replaced, call for
service
Buzzer is
continuously beeping
1 overload
1 remove the non
critical devices
Red LED is lit
battery failure
recharge the UPS for
at least 4 hours, if the
problem is not solved,
replace the battery,
call for service