Trust 71017-02 Скачать руководство пользователя страница 9

ASUN-650 SUN BLINDS SWITCH

1

1. Switch off the mains power (electric meter box) 

before installing this product

2. Remove the existing switch

Detach the existing switch and disconnect the wires. 

The existing wall switch is replaced by this product and can 

no longer be used. Consult the supplier of your sun blind 

system when in doubt about motor type and wire colors.

3. Connect 230V power supply

Connect the (brown) live wire to the [L] contact. 

Connect the (blue) neutral wire to the [N] contact. 

Contact an electrician when in doubt about wire colors. 

Tighten the clamping screws.

4. Connect motor wiring

How to connect the motor wiring depends on 

the type of motor: 

•  Read step 5 for a 230V motor.

•  Read step 6 for a 12-24V motor.

•  Read step 7 for a motor with a momentary switch.

5. Connect 230V motor

1.  Connect the (blue) neutral wire from the motor to 

  the [N] contact. 

2.  Use a seperate piece of wire to connect [L] with [COM]. 

3.  Connect the live wires from the motor (brown and black)  
  to the [

] and [

] contact. These positions can 

  be interchanged to reverse the up and down motion of 

  the motor.

6. Connect 12-24V motor

1.  Connect the 24V+ wire to [COM]. 
2.   Connect switch wires A and B to the [

] and [

]

contact. These positions can be interchanged 

  to reverse the up and down motion of the motor.  

  Never connect 230VAC wires to low-voltage wires.

7. Motor with momentary switch

The motor only has 2 wires. 
1.  Connect one wire to [

] and the other wire to [COM]. 

  These positions can be interchanged to reverse the up 

  and down motion of the motor. 

2.  Use a seperate piece of wire to connect both
 [

] and [

] contacts. Never connect 230VAC wires to 

  low-voltage wires.

8. Switch on the mains power (electric meter box) 

to continue the installation

Shock hazard! Do not contact any exposed wiring. 

Only touch the plastic housing of this product.

9. Activate learn-mode

Press the learn-button on the receiver for 1 second. 

The learn-mode will be active for 12 seconds and the 

LED-indicator will blink slowly.

10. Assign Trust Smart Home transmitter code

While the learn-mode is active, send an ON-signal with any 

Trust Smart Home transmitter to assign the code to the 

receiver’s memory.

EN

Содержание 71017-02

Страница 1: ...www trust com...

Страница 2: ...Item 71017 02 Version 1 0 Always read the instructions before using this product SUN BLINDS SWITCH USER MANUAL MULTI LANGUAGE START LINE RECEIVER ASUN 650 SWITCH IN...

Страница 3: ...ASUN 650 SUN BLINDS SWITCH 2 5 1 3 4 L L COM N n e u t r a l w i r e live wire L L COM N 230V Motor Wire 1 brown Neutral wire blue Ground yellow green 230V Neutral Blue 230V Live brown Wire 2 black...

Страница 4: ...50 SUN BLINDS SWITCH 7 9 6 8 12 24V Motor Switch wire A Switch wire B 230V Neutral blue 230V Live brown 0 V 12 24V DC Adapter L L COM N L L COM N 230VAC power supply 1 2 L L N COM 1 SEC Set Learn Lear...

Страница 5: ...ASUN 650 SUN BLINDS SWITCH 10 12 11 ON L L N COM 13 Learn Set ON OFF LED will blink fast...

Страница 6: ...ASUN 650 SUN BLINDS SWITCH 14 L L N COM OFF n u l d r a a d L L N COM 1 SEC L L N COM LED will blink fast...

Страница 7: ...ASUN 650 SUN BLINDS SWITCH n u l d r a a d L L N COM n u l d r a a d L L N COM L L N COM 6 SEC 1 SEC LED will blink fast...

Страница 8: ......

Страница 9: ...black to the and contact These positions can be interchanged to reverse the up and down motion of the motor 6 Connect 12 24V motor 1 Connect the 24V wire to COM 2 Connect switch wires A and B to the a...

Страница 10: ...dule contains 2 voltage free contacts and In the neutral position the contact COM is not switched After an on off signal from a Trust Smart Home transmitter COM switches either to the or contact After...

Страница 11: ...den Sie ein zus tzliches Kabel um L an COM anzuschlie en 3 Schlie en Sie die stromf hrenden Kabel des Motors braun und schwarz an der und an Diese Positionen k nnen getauscht werden um die Auf und Ab...

Страница 12: ...eder Befehl Heben Senken Anhalten muss zweimal erfolgen 14 Erl uterung der COM Buchse Das Modul enth lt zwei spannungsfreie Buchsen und In neutraler Stellung ist die Buchse COM nicht geschaltet Nach e...

Страница 13: ...r aux contacts et Ces positions peuvent tre modifi es pour inverser les mouvements de levage et d abaissement du moteur 6 Raccordement du moteur de 12 24 V 1 Raccordez le c ble 24V au contact COM 2 Ra...

Страница 14: ...s tension et Le contact COM n est pas activ en position neutre Apr s un signal d activation de d sactivation d un metteur Trust Smart Home le contact COM commute vers le contact ou Le contact COM revi...

Страница 15: ...contacten Deze posities kunnen worden omgedraaid om de op en neer beweging van de motor om te draaien 6 Motor van 12 24 V aansluiten 1 Sluit de draad 24V op COM aan 2 Sluit de schakeldraad A en B aan...

Страница 16: ...op de COM aansluiting De module bevat twee spanningsvrije contacten en In de neutrale stand is het contact COM niet ingeschakeld Na een AAN UIT signaal van een Trust Smart Home zender schakelt het COM...

Страница 17: ...el motore marrone e nero al contatto e Queste posizioni possono essere scambiate per invertire il movimento del motore 6 Collegamento del motore a 12 24 V 1 Collegare il filo a 24 V a COM 2 Collegare...

Страница 18: ...dulo contiene 2 interruttori liberi da tensione e In posizione neutra il contatto COM non attivo Dopo un segnale di ON OFF da un trasmettitore Trust Smart Home COM si sposta o sul e contatto Dopo 2 mi...

Страница 19: ...y Estas posiciones se pueden intercambiar para invertir los movimientos hacia arriba y hacia abajo del motor 6 Conecte el motor de 12 24V 1 Conecte el cable de 24V a COM 2 Conecte los cables del inte...

Страница 20: ...tensi n y En la posici n neutra el contacto COM no est encendido Tras la se al de encendido apagado de un transmisor Trust Smart Home COM cambia al contacto y Al cabo de dos minutos el contacto COM v...

Страница 21: ...t till och kontakt De h r placeringarna kan bytas f r att v nda motorns upp och nedr relse 6 Ansluta 12 24 V motor 1 Anslut 24 V kabeln till COM 2 Anslut str mbrytarkablarna A och B till och kontakt D...

Страница 22: ...ch konta I neutrall get r COM kontakten inte p slagen Efter en ON OFF signal fr n en Trust Smart Home s ndare v xlar COM till antingen till och kontakt Efter tv minuter v xlar COM kontakten tillbaka t...

Страница 23: ...a ern k kontaktu a Tyto pozice lze zm nit oto te tak pohyb motoru nahoru a dol 6 P ipojte 12 24V motor 1 P ipojte 24V vodi ke COM 2 P ipojte vodi e vyp na e A a B k kontaktu a Tyto pozice lze zm nit...

Страница 24: ...kontaktu COM Modul obsahuje dva kontakty k p epnut nap t a V neutr ln pozici nen kontakt COM zapnut Po sign lu zap vyp od vys la e Trust Smart Home se COM p ipoj k kontaktu nebo Po dvou minut ch se k...

Страница 25: ...d a ierny k kontaktu a Tieto polohy m ete medzi sebou vymeni na obr tenie behu motora 6 Pripojenie motora s nap t m 12 24 V 1 Pripojte vodi 24 V ku COM 2 Pripojte k ble prep na a A a B k kontaktu a Ti...

Страница 26: ...aktu COM Modul obsahuje 2 kontakty bez nap tia a V neutr lnej polohe sa kontakt COM neprepne Po sign le zapnutia vypnutia z vysiela a Trust Smart Home sa COM prepne bu do kontaktu alebo Po 2 min tach...

Страница 27: ...i negru la contactele i Pozi iile pot fi schim bate pentru a inversa mi carea n sus i n jos a motorului 6 Conectarea motoarelor de 12 24V 1 Conecta i firul 24V la COM 2 Conecta i firele de ntrerupere...

Страница 28: ...COM Modulul con ine 2 contacte lipsite de tensiune i n pozi ia neutru contactul COM nu este comutat Dup un semnal de pornire oprire de la un transmi tor Trust Smart Home COM comut la contactul sau Dup...

Страница 29: ...charged Dispose of batteries according to local regulations Trust Electronics Ltd declares that item number 71017 02 is in compliance with Directive Electromagnetic Compatibility Regulations 2016 Radi...

Страница 30: ...tark abh ngig von den rtlichen Gegebenheiten wie dem Vorhandensein von HR Glas und stahlbewehrtem Beton Trust Smart Home Produkte d rfen nicht f r lebenserhaltende Systeme eingesetzt werden Dieses Pro...

Страница 31: ...es avec les d chets m nagers Ne mettez les piles au rebut que lorsqu elles sont enti rement d charg es Proc dez leur limination conform ment aux r glementations locales applicables Gamme de fr quence...

Страница 32: ...ste producto no es resistente al agua No trate de reparar este producto usted mismo Los colores de los cables pueden variar entre pa ses P ngase en contacto con un t cnico electricista si tiene dudas...

Страница 33: ...1017 02 uppfyller kraven i direktiv 2014 53 EU 2011 65 EU Den fullst ndiga texten i EU f rs kran om verensst mmelse finns p f ljande webbadress www trust com compliance CS Bezpe nostn pokyny Podpora p...

Страница 34: ...na tejto internetovej adrese www trust com compliance RO Instruc iuni de siguran Asisten produs www trust com 71017 Condi ii privind garan ia www trust com warranty Pentru a asigura manipularea n sigu...

Страница 35: ...of the following directives ROHS 2 Directive 2011 65 EU RED Directive 2014 53 EU The full text of the EU declaration of conformity is available at the following web address www trust com compliance T...

Страница 36: ...SUN BLINDS SWITCH TECHNICAL SPECIFICATIONS Codesystem Automatic Memory addresses 32 Wattage Max 1000 Watts Voltage 230V 50Hz Voltage to be connected 12 24V DC 230V AC potential free Size HxWxL 48 x 4...

Отзывы: