Technical specifications
ENGLISH
Power Requirements
Power cord grips: Type “Y”.
Build quality: Basic insulation.
Thermal insulation on motor winding: Class H
29959
29960
29958
Codes
Description
SOIN-110/130P
SOIN-101P
SOIN-120/160P
Rated Input Capacity
Input Voltage
Current Range
20 A - 110 A / 20 A - 130 A
20 A -120 A / 20 A -160 A
20 A - 100 A
Power Factor
Cos 0.73
Inverter Welder
127 V / 220 V / 60 Hz
127 V / 60 Hz
SMAW: 1/16” - 5/32”
TIG: 0.040”
SMAW: 1/16” - 5/32”
TIG: 0.040” - 0.062”
SMAW: 1/16” - 1/8”
TIG: 0.040”
Electrode
IP21S
IP Grade
6.3 lb
7.2 lb
7.4 lb
Dimension
60%
6 minutes’ work per 4 minutes’ rest.
Output values specified are with a 68 ºF Temperatures higher than the work cycle may be reduced.
Rated Duty Cycle
Insulation
Class I
12 AWG x 2C with 221 °F insulation temperature
Conductors
Weight
WARNING
WARNING
Avoid the risk of electric shock or severe injury. When the power cable gets damaged
it should only be replaced by the manufacturer or at a Authorized Service Center.
The build quality of the electric insulation is altered if spills or liquid gets into the tool while in use.
Do not expose to rain, liquids and/or dampness.
Before gaining access to the terminals all power sources should be disconnected.
4.3 kVA / 5.3 kVA
3.8 kVA
4.8 kVA / 6.8 kVA
If faults or breakdowns happen. Ground connection offers a
trajectory with minimum resistance for electric power. It reduces the risk of electric
shock. This tool is built with a power cable with an earth conductor and a plug with
ground connection. The plug shall be connected into a power outlet installed and
grounded according to all local codes.
Do not modify the plug supplied. If the plug cannot be fitted
to the socket, have a qualified electrician to install the suitable socket.
• When using the welder together with more tools using the same ground connect those in parallel, never connect a
series.
• The gauge of the ground conductor cable shall not be of a smaller gauge than the power supply cable.
• Connection to the power supply shall only be carried out by a professional electrician.
• Double check the input connection voltage stipulated in the welder nameplate matches the power
supply voltage.
• The power supply cord shall meet the following requisites:
CAUTION
CAUTION
CAUTION
* The current for fuse fusion is double of its rated current.
Switch
Fuse (Work Rated Current)
Electric Wire
30 A
30 A (*)
2.5 mm
2
• If extensions between the welder and the work piece
are needed, the soldering cable gauge shall be increased
to keep the welder energy output with a potential drop
not higher than 4 V
CAUTION
WARNING
WARNING
11.8” x 4.7” x 8.2”
Open Circuit Voltage
127 V - 75 V c.c.
220 V - 65 V c.c.
69 V c.c.