4
Connections (see pages 37 & 38)
High Speed Inputs
These are high speed inputs (10kHz max), suitable only for electronic signal
sources, eg. transistors, proximity switches, encoders.
Low Speed Inputs
These are low speed inputs (30Hz max), suitable for contact closure sources,
eg. microswitches, relays, pushbuttons. Any contact noise is removed by
filtering. They can also be used for electronic signal sources.
Wire Size
Maximum wire size the connector can accept is:
2.5mm
2
cross sectional area; 1.8mm diameter. (equivalent 13 AWG solid wire)
Pin Description
Range
1
Live
2
Neutral
94 to 240VAC ±10% 50/60 Hz
3
Auxilliary DC ve
Power Supply (see pages 37 & 38)
The counter can be powered by AC mains, in which
case pins 3 and 11 provide an Auxilliary supply (+12V
DC ±10%, 100mA max) which can be used to power
sensors if required.
Alternatively, the counter can be powered by an
external DC source (12-24V DC ±10%, 100mA),
connected to pins 3 and 11.
4
Normally Open contact
5
Common contact
6
Normally Closed contact
Isolated relay contacts
50/60Hz 300V AC max, 220V DC max
See
Specification, page 2
7
Not used
---------
8
High Speed Counter Input
(Input CH)
Opto-isolated, 10-30 VDC See
Specification, page 2
This input can be used in Counter Mode only
9
Keyboard Disable Input
(Input K)
Opto-isolated, 10-30 VDC See
Specification, page 2
This input can be used to disable the front panel
buttons, but only if configured by the
Inhibit option.
See
Programming, page 6
10
8/9 Common
See
Input Polarity, page 5
11
Auxilliary DC Supply -ve
0V - See pin 3, above
12
Low Speed Counter/Timer
Input
(Input CT)
Opto-isolated, 12-240 V ±10% DC or 50/60Hz AC
See
Specification, page 2
This input can be used in Counter or Timer Mode
13
External Reset Input
(Input R)
Opto-isolated, 12-240 V ±10% DC or 50/60Hz AC
See
Specification, page 2
14
12/13 Common
See
Input Polarity, page 5