![Truma Vicon 2 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/truma/vicon-2/vicon-2_installation-instructions-manual_1176022010.webp)
10
Touch Panel connection
Only connection the Touch Panel (TP) using a Y-adapter (Y) to
a Power Module (PM).
Install the Y-adapter (part no. C30000-03300) in a place (wall
or floor) protected against moisture and wetness close to
the Power Module (PM). Fix the Y-adapter with cable ties if
necessary.
R
COM2
COM1
COM1
Y
PM
TP
-Y
+Y
The Y-adapter connection cables may not be extended.
Connecting the Truma Combi heating
A TIN cable is necessary for connection of the heating to the
COM3 connection of a module (PM).
COM2
COM1
COM2
COM1
COM2
COM1
COM3
COM3
R
PM
PM
PM
Combi
TIN
CAN
CAN
CAN
TIN
TIN cable 3 m (part no. C30000-05000)
TIN cable 6 m (part no. C30000-05100)
Connecting the Alde Compact 3010 heating
An interface (AVI) is necessary to connection the Alde heating
Compact 3010 to the Vicon 2 bus system.
Connect the device using the interface with COM3 of a
module (PM).
The Alde room temperature sensor (A) must be
connected at the AVI.
COM2
COM1
COM2
COM1
COM2
COM1
COM3
COM3
R
PM
PM
PM
TIN
CAN
CAN
CAN
Alde
Compact
3010
AVI
A
A
Alde Room temperature sensor
AVI
Alde-Vicon-Interface (part no. C30000-03500)
TIN
TIN cable 3 m (part no. C30000-05000)
TIN cable 6 m (part no. C30000-05100)
Adaption / consumers connection
Adaption of the connection (of consumers) only takes
place through the vehicle manufacturer.