5
Switching on gas operation
UltraRapid
60°
70°
b
b
a
c
Fig. 3
a = Red indicator lamp “Fault”
b = Water heater “On” 60 °C or 70 °C
c = Water heater “Off”
Never operate the water heater without water in it!
If the wall cowl is positioned close to
an opening window (or hatch) – in
particular directly under it – it must
remain closed when the water heat-
er is in use (see warning plate).
1
Fig. 3a
– Remove cowl cover (Fig. 3a).
– Open gas cylinder and open stop
cock valve in the gas supply line.
– Switch on water heater at the switch on the control panel (b).
When using the vehicle switches
Refer to operating instructions of the vehicle manufacturer or
see switch labels.
If there is air in the gas supply line, it may take up to a minute
before the gas is available for combustion. If the appliance
switches to “Fault” during this time, switch off the appliance
– wait 10 minutes – and switch on again!
Switching off gas operation
– Switch off the water heater to position (Fig. 3 - c).
If the water heater is not to be
used for a longer period, mount
cowl cover (non-observance of this
point can lead to the function of the
appliance being impaired through
water, dirt or insects), close stop
cock valve in the gas supply line
and close the gas cylinder.
2
1
Fig. 4
Before setting off on any journey, fit cowl cap with the
Truma UltraRapid HWS switched off. Please ensure that
it is secure and has locked into place (risk of accident). De-
fective cowl caps must not be used.
Drain the water heater if
there is a risk of frost! Warranty claims will not be accepted
if this is ignored.
Red indicator lamp “Fault“
The red indictor lamp (a) lights up if there is a fault. For possi-
ble causes please refer to page 5 – “Fault finding”. To unlock,
switch off the appliance, wait 10 minutes, and switch on
again.
Electrical operation 230 V ~ / 240 V ~
– option –
230 V ~ / 240 V ~ 1300 W / 1415 W (5.7 A / 5.9 A)
The Truma UltraRapid HWS must not be operated
with a time switch.
Never operate the Truma UltraRapid HWS without
water in it!
– To operate the electric heating element, insert the plug into
the socket and then turn it on with the switch.
The electric heating element is operational when you can see
the mark (Fig. 5 - g) on the switch.
Fig. 5
The water temperature cannot be selected, automatic
temperature limitation at approx. 70 °C! For a faster
heating up period the appliance can be simultaneously oper-
ated with gas
and
electrical power.
Maintenance
Materials in the device which come into contact with wa-
ter are suitable for use with drinking water (see manufac-
turer declaration: www.truma.com – Manufacturer Declaration).
– The Truma UltraRapid HWS must be descaled on a regular
basis (at least twice a year).
We recommend the use of suitable normal commercial
products for the cleaning, disinfection and care of the
Truma UltraRapid HWS. Products containing chlorine are
unsuitable.
– In order to avoid the colonization of micro-organisms, heat
up the Truma UltraRapid HWS to 70 °C at regular intervals.
– The drain valve (Fig. 2 - 3) and the P&T safety valve (Fig. 2
- 4) are to be operated regularly to remove lime deposits
and to ensure that they are not blocked. Frequency: every 6
month.
Fuses
The water heater 12 V fuse is on the PCB on the water heater.
Important note
Only replace the miniature fuse on the PCB with a fuse of the
same type: 1.6 A (slow action).
1.6 A
Fig. 6
If there is a defect in the electronics, return the PCB well
padded. If you fail to pack it correctly, the warranty shall
no longer be valid.
Only use original Truma UltraRapid HWS - PCB as spare parts!