Truma UltraRapid Скачать руководство пользователя страница 4

4

Pressure and Temperature Relief Valve 
(P&T safety valve)

Risk of scalding injury from hot water and/or tamper-
ing with the P&T safety valve!

 

– Do not actuate the P&T safety valve as long as the 

appliance is still hot.

 

– Do not place a plug or reducing coupling in the 

discharge pipe (Fig. 2a - 4b) of the P&T safety valve.

 

– Do not operate the water heater without a 

functioning P&T safety valve - this could cause an 
explosion.

The P&T safety valve (4) is a safety component and must
not be removed for any reason other than replacement.

The P&T safety valve is not serviceable; if defective it must be 
replaced (failure to reuse an old P&T safety valve). It must be 
replaced by a certified service technician.

Tampering with the P&T safety valve will void the warranty.

close

open

4

4b

4a

Fig. 2a

P&T safety valve

4a Test 

lever

4b Discharge 

pipe

Draining the water heater

If the vehicle is not used during periods of frost, it is es-
sential that the Truma UltraRapid HWS be emptied.

 

– Disconnect power for water pump (main switch or pump 

switch).

 

– Allow the appliance to cool down.

 

– Open hot water taps in bathroom and kitchen.

 

– Open drain valve (Fig.2 - 3).

Lever in the “f” position (drain).

The water heater is now drained directly to the outside via 
the drain valve (3). 

 

– Check that the water has been completely drained (14 litres).

Always observe the operating instructions prior to 
starting!

 The vehicle owner is responsible for correct opera-

tion of the appliance.

Before using the product for the first time, it is essen-
tial to flush the entire water supply through with clean 

warm water. Always mount the cowl cap when the water 
heater is not being operated! Drain the water heater if there is 
a risk of frost!

 Warranty claims will not be accepted for frost 

damage. 

Always remove the cowl cover prior to operating the 
water heater!

If connecting to a central water supply (rural or city connec-
tion) or when using more powerful pumps, a pressure reduc-
er must be used which prevents pressures of greater than 
400 kPa occurring in the Truma UltraRapid HWS.

Filling the Truma UltraRapid HWS with water

Check that the drain valve (3) and the P&T safety valve (Fig. 
2a - 4) in the cold water intake are closed. 

 

– Close drain valve (Fig. 2 - 3).

Lever in the “e” position (close).

 

– Test lever (Fig. 2a - 4a) of the pressure relief valve (4) must 

be in the “close” position.

e

e

f

e = close
f = drain

3

Fig. 2

 

– Open hot tap in bathroom or kitchen, with pre-selecting 

mixing taps or single-lever fittings set to “hot”. 

 

– Switch on power for water pump (main switch or pump 

switch).

 

– Leave the tap open to let air escape while the water heater 

is filling. The heater is filled when water flows out of the tap.

Residues of frozen water can prevent filling if there is a frost. 
The water heater can be defrosted by switching on the heater 
for a short period (max. 2 minutes). Frozen pipes can be de-
frosted by heating the room.

If just the cold water system is being used, without 
water heater, the heater tank is also filled up with wa-

ter. In order to avoid damage through frost, water must be 
drained by means of the drain valve, even if the heater has 
not been used. As an alternative, two shut-off valves, resistant 
to hot water, can be fitted in front of the cold and hot water 
connection.

Operating instructions

Содержание UltraRapid

Страница 1: ...Operating instructions Page 4 Installation instructions Page 8 To be kept in the vehicle Truma UltraRapid Hot Water System LPG and 230 V 240 V Electric Storage Water Heater...

Страница 2: ...lt finding 6 Technical data 6 Truma warranty policy 7 Installation instructions Data label 8 Intended use 8 Regulations 8 Water heater kit 8 Choice of location 8 Installation of the water heater 8 Wat...

Страница 3: ...the P T safety valve is to be installed in a continuously downward direction and in a frost free ambient Before accessing terminals please ensure all supply circuits are disconnected i e 230 V 240 V...

Страница 4: ...tire water supply through with clean warm water Always mount the cowl cap when the water heater is not being operated Drain the water heater if there is a risk of frost Warranty claims will not be acc...

Страница 5: ...ease refer to page 5 Fault finding To unlock switch off the appliance wait 10 minutes and switch on again Electrical operation 230 V 240 V option 230 V 240 V 1300 W 1415 W 5 7 A 5 9 A The Truma UltraR...

Страница 6: ...ly Allow the appliance to cool and then slowly raise the test lever Fig 2a 4a to flush the water system and attempt to force dirt or foreign matter out of the P T safety valve seat Replace P T safety...

Страница 7: ...check carefully the operating instructions warranty terms and conditions If the product fails for any of the reasons detailed therein or is faulty due to abuse misuse or improper installation then a s...

Страница 8: ...unt sealing frame 3 the anti twisting device ensures correct fitting Pre drill holes for the 6 fastening bolts 4 Installation of the unit may only be carried out by properly qualified professionals Th...

Страница 9: ...ater and the resulting expansion All hot water pipes should be routed in a descending man ner to the drain valve Otherwise there is no guarantee of protection from frost Installation of the pressure r...

Страница 10: ...valve 14 and elbow 13 lower pipe on water heater Pressure reducer B The pressure reducer 10 must be fitted between the drain valve and water pump in accordance with the direction of flow indicated by...

Страница 11: ...not possible use the surface mounting frame 25 as supplied Electrical connection 12 V Disconnect device from power supply before starting to work on electrical components Switching off at the control...

Страница 12: ...cable supply cord is damaged it must be replaced by the manufacturer its service agent or simi larly qualified persons in order to avoid a hazard Fig 21 In order to operate the element the manufacture...

Страница 13: ...13 BGA 14 BGEA 14 LPG Propane and 230 V 240 V Electric Storage Water Heater When ordering spare parts please always state the serial number and year of manufacture...

Страница 14: ...rown BU blue GN green GY green yellow OG orange RD red WH white YE yellow WH BN GN YE GY Electrical Connection Diagram Truma UltraRapid Hot Water System Safety Valve PC Push Coil HC Holding Coil RD GN...

Страница 15: ...15...

Страница 16: ...elevant service partners should be contacted www truma com Having the equipment model and the serial number ready see type plate will speed up processing Service Australia Telephone 61 0 3 92 39 10 50...

Отзывы: