Draining the boiler

The boiler must be drained if the motor home / caravan 

is not being used during the frosty period.

 

– Switch off the power to the pump assembly (main switch or 

pump switch).

 

– Open hot water taps in kitchen and bathroom.

In order to check the water that is flowing out, place an 

appropriate container (capacity 10 litres) beneath the 

drainage socket (d) of the safety/drain valve.

 

– Open safety/drain valve 

(see “Opening the safety/drain valve”).

The boiler will now be drained directly to the outside via 

the safety/drain valve. Check whether all of the water in the 

boiler (10 litres) has been drained into the container via the 

safety/drain valve. 

No claims may be made under the warranty for damage 

caused by frost.

Initial start-up

(or when the fuel tank has run empty)

Filling the fuel lines

The heater normally has to be started up several times to fill 

the fuel lines if an automatic filling device is not being used.

Check to make sure the cowl is unobstructed. Remove any 

covers that may be present.

Switch off unit at control panel. The unit automatically 

performs 2 starting attempts (initial start and repeat) per 

switch-on procedure with a run time of 2 minutes in each 

case. If no flame is detected after the repeat start, the unit 

switches to fault and has to be switched off and on again at 

the  control panel. 

After a total of 15 unsuccessful starting attempts (initial 

and repeat start) without forming a flame, the equipment 

is blocked. To remove the block, please contact the Truma 

Service Centre or one of our authorised service partners (see 

www.truma.com).

Check fuel lines and connections for leaks after filling the fuel 

lines. 

Start-up

Combi D 6

The interior can be heated either with or without water, de-

pending on the setting. 

Combi D 6 E

The interior can be heated in diesel, electrical or mixed 

mode, either with or without water, depending on the 

setting. 

Check whether the power supply fuse protection at the camp 

site is adequate for the 900 W (3.9 A) or 1800 W (7.8 A) that 

have been selected using the power selector switch.

The cable drum must be fully unwound in order to prevent 

the power cable from overheating.

 

– Check to make sure the cowl is unobstructed. Remove any 

covers that may be present.

 

– Fill boiler with water if necessary (see “Filling the boiler”).

 

– Switch on the unit on the control panel.

Switching off

 

– Switch the heater off on the control panel. 

 

– The switch-off procedure may be delayed by several min-

utes because of internal heater operations.

Always drain water contents if there is a risk of frost!

Maintenance

Only original Truma parts may be used for maintenance and 

repair work.

 

– Even out of season, the heater should be operated once a 

month for about 10 minutes.

 

– The safety/drain valve (FrostControl) must be operated regu-

larly (at least twice annually) to remove limescale deposits 

and to be certain that it is not blocked.

We recommend the use of suitable commercially available 

products to clean, sterilise and maintain the boiler. Products 

containing chlorine are not suitable.

The effectiveness of the use of chemicals to combat micro-

organisms in the appliance can be increased by heating the 

water in the boiler to 70 °C at regular intervals.

Combi D 6 E

– Select diesel mode.

 

– Set the water temperature to 60 °C. 

 

– Switch on the appliance.

Once the water in the boiler has reached a temperature 

of 60 °C, the burner will switch off. The appliance must 

stay switched on for at least 30 minutes and no hot water 

may be removed. The residual heat in the heat exchanger will 

heat the water up to 70 °C.

Fuses

Fuses 12 V

The fuses are located in the electronics, beneath the connector 

cover. When replacing a fuse, be sure to use the same type.

Appliance fuse:   10 A – slow-acting – 5 x 20 mm (T 10 A)

Burner fuse: 

20 A – slow-acting – 6.3 x 32 mm

T 20 A

T 10 A

Figure 4

Содержание Combi D 6 (E)

Страница 1: ...EN Operating instructions To be kept in the vehicle t Combi D 6 E Page 02...

Страница 2: ...ature sensor 3 Cold water connection 4 Hot water connection 5 Fuel line connection 6 Warm air outlets 7 Circulated air intake 8 Exhaust gas discharge 9 Combustion air infeed 10 Electronic control unit...

Страница 3: ...ns In the event of a leak in the heater or the exhaust duct Switch off the unit Open windows and doors Have the entire system inspected by an expert Guaranteeing a safe operating environment The unit...

Страница 4: ...er must not be used during refuelling or in enclosed car parks in garages or on ferries To prevent damage to the appliance from spray water such as when cleaning the ve hicle do not spray water direct...

Страница 5: ...ly heated as well The water temperature depends on the selected operating mode and the heater output All 3 energy selection options can be used for winter deployment In diesel mode the unit automatica...

Страница 6: ...hether the rotary switch is set to On position a i e parallel to the water connection and engaged Close the safety drain valve by pressing the pushbutton The pushbutton must engage in position b close...

Страница 7: ...diesel electrical or mixed mode either with or without water depending on the setting Check whether the power supply fuse protection at the camp site is adequate for the 900 W 3 9 A or 1800 W 7 8 A th...

Страница 8: ...Power consumption at 230 V 3 9 A 900 W or 7 8 A 1800 W Weight without water Heater 15 8 kg 16 9 kg Combi D 6 E Heater with peripheral devices 17 2 kg 18 3 kg Combi D 6 E E1 122R 00 0232 E1 10R 04 527...

Страница 9: ...the operating instructions for the con trol panel that is installed Faults Water supply Possible fault causes and a troubleshooting guide See Troubleshooting guide water supply Troubleshooting guide w...

Страница 10: ...he relevant country of purchase In individual countries there may be warranties that can be issued by the relevant dealer official distributor Truma Partner In such cases the warranty can be implement...

Страница 11: ...9 4617 2020 Telefax 49 0 89 4617 2159 service truma com www truma com EN Should problems occur please contact the Truma Service Centre or one of our authorised service partners see www truma com In or...

Отзывы: