Truma Combi D 6 (E) Скачать руководство пользователя страница 3

3

EN

 

– Do not operate the unit anywhere where 

flammable vapours or dust can form, e.g. 
in the vicinity of a fuel, coal, wood or grain 
storage facility or similar.

 

– A diesel heating system always requires 

more power than a comparable gas heating 
system. If there is a requirement for autarky 
of the same duration (service life without 
external power supply), Truma recommends 
investigating the possibility of retrofitting a 
larger and / or second battery.

Obligations of the operator / vehicle owner

– The operator is responsible for the water 

with which the unit’s boiler is filled and for 
its quality.

– The vehicle owner is responsible for correct 

operation of the appliance.

– The installer or vehicle owner must affix the 

supplied yellow sticker with the warning 
information in a location in the vehicle 
where it is clearly visible to all users (e.g. 
the wardrobe door). Missing stickers can be 
requested from Truma.

 

– The system must comply with the respect- 

ive regulations of the country in which it is 
used. National regulations and rules must be 
followed.

 

– The exhaust system must be inspected by a 

qualified technician at regular intervals, not 
exceeding 2 years.

 

– If the heater is not being used, always drain 

off the water if there is a risk of frost. No 
claims may be made under the warranty for 
damage caused by frost.

Safety instructions 

In the event of a leak in the heater or the 

exhaust duct:

 

– Switch off the unit,

 

– Open windows and doors,

 

– Have the entire system inspected by an 

expert.

Guaranteeing a safe operating environment

 

– The unit may be operated only with appropri-

ate Truma control panels and accessories.

 

– Danger of toxic exhaust fumes. The heater’s 

exhaust can be toxic in enclosed spaces (e.g. 
garages, workshops). If the vehicle is parked 
in closed rooms:
– Shut off the fuel supply to the heater
– Deactivate the time switch
– Switch off the heater at the control panel.

– If the cowl has been placed near or directly 

beneath an opening window, the appliance 
must be equipped with an automatic shut-off 
device in order to prevent operation with the 
window open.

 

– Heat-sensitive objects (e.g. spray cans) or 

flammable materials/ liquids may not be 
stored in the same compartment where the 
heater is installed because, under certain 
conditions, this area may be subject to el-
evated temperatures.

 

– Keep flammable materials away from the 

area in front of the warm air outlets. Never 
block the warm air outlets.

 

– The openings for circulated air intake, the 

installation compartment and the space 
around the unit must be kept free of ob- 
stacles so that the unit does not overheat.

 

– The cowl and the combustion air infeed must 

be kept free of dirt (e.g. slush, ice, leaves, 
etc.) at all times in order to guarantee clean 
combustion.

 

– Danger from hot surfaces and exhaust gas. 

Do not touch the area around the wall cowl 
and do not lean any objects against the wall 
cowl or the vehicle.

Содержание Combi D 6 (E)

Страница 1: ...EN Operating instructions To be kept in the vehicle t Combi D 6 E Page 02...

Страница 2: ...ature sensor 3 Cold water connection 4 Hot water connection 5 Fuel line connection 6 Warm air outlets 7 Circulated air intake 8 Exhaust gas discharge 9 Combustion air infeed 10 Electronic control unit...

Страница 3: ...ns In the event of a leak in the heater or the exhaust duct Switch off the unit Open windows and doors Have the entire system inspected by an expert Guaranteeing a safe operating environment The unit...

Страница 4: ...er must not be used during refuelling or in enclosed car parks in garages or on ferries To prevent damage to the appliance from spray water such as when cleaning the ve hicle do not spray water direct...

Страница 5: ...ly heated as well The water temperature depends on the selected operating mode and the heater output All 3 energy selection options can be used for winter deployment In diesel mode the unit automatica...

Страница 6: ...hether the rotary switch is set to On position a i e parallel to the water connection and engaged Close the safety drain valve by pressing the pushbutton The pushbutton must engage in position b close...

Страница 7: ...diesel electrical or mixed mode either with or without water depending on the setting Check whether the power supply fuse protection at the camp site is adequate for the 900 W 3 9 A or 1800 W 7 8 A th...

Страница 8: ...Power consumption at 230 V 3 9 A 900 W or 7 8 A 1800 W Weight without water Heater 15 8 kg 16 9 kg Combi D 6 E Heater with peripheral devices 17 2 kg 18 3 kg Combi D 6 E E1 122R 00 0232 E1 10R 04 527...

Страница 9: ...the operating instructions for the con trol panel that is installed Faults Water supply Possible fault causes and a troubleshooting guide See Troubleshooting guide water supply Troubleshooting guide w...

Страница 10: ...he relevant country of purchase In individual countries there may be warranties that can be issued by the relevant dealer official distributor Truma Partner In such cases the warranty can be implement...

Страница 11: ...9 4617 2020 Telefax 49 0 89 4617 2159 service truma com www truma com EN Should problems occur please contact the Truma Service Centre or one of our authorised service partners see www truma com In or...

Отзывы: