8
4. Beginning from the centre, secure the unit with the
12 screws provided.
X
X
7
11
5
1 3
10
9
8
2
4
6
12
Fig. 13
5. Position the outer grille and beginning from the centre
s ecure with 11 screws provided. Use the provided plastic
spacers on the outer screws.
Clim
aste
r
Climaster
4
6
8
9
7
3
5
11
10
2
1
Fig. 14
The condensation water drain is located on the side of
the vehicle. In order for the condensation water to drain
away freely, after the installation a check should be made to
ensure that the drain hose is free of dirt, vegetation residue, or
similar obstructions.
If this is not done, there is a risk of
conden sation water penetrating into the vehicle.
6. Secure the air conditioning unit with the tensioning belt (1)
as illustrated.
1
1
Fig. 15
3. Using a jigsaw or padsaw cut to the lines shown on the
template. Remove the template.
4. The hole in the caravan wall must be lined with timber to
give a firm support for holding the unit in position.
area cut-away
for clarification
Fig. 10
Use a non hardening mastic to seal the the lining to the inner
and outer walls – do not use silicone! Secure the inner walls
to the lining with panel pins.
The finished hole should be 275 mm high and 660 mm wide.
Fitting the air conditioning unit
1. Take the second template and place inside the vehicle in
such a way that
outer line (C)
is
level with the outer wall
and mark the points (E) for the securing brackets.
E
E
C
Fig. 11
2. Remove the template. Position the tensioning belt (1) and
secure to the vehicle floor with the two securing brackets (2),
using two screws (3) each.
1
2
3
1
Fig. 12
3. Offer the air conditioning unit through the hole in the wall,
making sure that the 240 V cable is not trapped under the unit.
Important note
To avoid damages, only hold the unit by the outer
frame. Do not push against the inner part of the unit!