 Warning to hearing aid dispensers (US Only) 

A hearing aid dispenser should advise a prospective hearing aid user to consult promptly with a licensed 
physician (preferably an ear specialist) before dispensing a hearing aid if the hearing aid dispenser de-
termines through inquiry, actual observation, or review of any other available information concerning the 
prospective user, that the prospective user has any of the following conditions:
  (i)  Visible congenital or traumatic deformity of the ear.
  (ii)  History of active drainage from the ear within the previous 90 days.
  (iii)  History of sudden or rapidly progressive hearing loss within the previous 90 days.
  (iv)  Acute or chronic dizziness.
  (v)  Unilateral hearing loss of sudden or recent onset within the previous 90 days.
  (vi)   Audiometric air-bone gap equal to or greater than 15 decibels at 500 hertz (Hz),  

1,000 Hz, and 2,000 Hz.

 (vii)  Visible evidence of significant cerumen accumulation or a foreign body in the ear canal.
 (viii)  Pain or discomfort in the ear.

Important notice for prospective hearing aid users (US Only)

Good health practice requires that a person with a hearing loss have a medical evaluation by a licensed 
physician (preferably a physician who specializes in diseases of the ear) before purchasing a hearing aid. 
Licensed physicians who specialize in diseases of the ear are often referred to as otolaryngologists, otolo-
gists or otorhinolaryngologists. The purpose of medical evaluation is to assure that all medically treatable 
conditions that may affect hearing are identified and treated before the hearing aid is purchased.

400846011US-17.10-Rev.A.indd   42

02-10-2017   14:47:59

Содержание Flyte RIE

Страница 1: ...User Guide Flyte RIE User Guide Flyte BTE User Guide Flyte BTE User Guide Flyte BTE 400846011US 17 10 Rev A indd 1 02 10 2017 14 46 59...

Страница 2: ...ial installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruc tions may cause harmful interference to radio communi...

Страница 3: ...ied under the rules of ISED Japanese Radio Law and Japanese Telecommunications Business Law Compliance This device is granted pursuant to the Japanese Radio Law and the Japanese telecommunications Bus...

Страница 4: ...However children and physically or mentally challenged users will re quire training by a doctor audiologist hearing healthcare professional or the guardian for the insertion and removal of the hearin...

Страница 5: ...are important in learning to use hearing instruments Your hearing instruments have been adjusted according to your indi vidual hearing loss and needs Some people adjust quickly to wearing hearing ins...

Страница 6: ...6 Hearing instrument model Model 62 Battery size 13 Receiver tube length Dome size Left serial number Right serial number 400846011US 17 10 Rev A indd 6 02 10 2017 14 46 59...

Страница 7: ...FL962 DRW HP FL962 DRW MP FL962 DRW LP FP962 DRW UP FP962 DRW HP FP962 DRW MP FP962 DRW LP FL762 DRW UP FL762 DRW HP FL762 DRW MP FL762 DRW LP FP762 DRW UP FP762 DRW HP FP762 DRW MP FP762 DRW LP The i...

Страница 8: ...ti Function buttons 16 Flight mode Wireless models only 19 Telephone use 20 Listen to radio or TV 21 Using hearing instruments with iPhone iPad and iPod touch 21 Cellular phones 21 PhoneNow 22 Telecoi...

Страница 9: ...warnings 38 TSG precautions 38 TSG warning to hearing healthcare professionals 39 Battery warning information 40 Hearing instrument expectations 41 Warning to hearing aid dispensers US Only 42 Importa...

Страница 10: ...Power Dome 5 RIE mold 6 Sports lock 7 Battery compartment 8 Receiver 9 Push button 10 Volume Control optional 11 LP receiver tube 12 MP receiver tube 13 HP receiver tube 14 Model and serial number in...

Страница 11: ...in which the hearing instruments turn on after the battery compart ment is closed With SmartStart a beep will be heard for each second of the delay period Inserting Replacing the battery 1 Open the ba...

Страница 12: ...earing care professional for a list of appropriate batteries Low battery indicator When the batteries are low on power your hearing aids reduce the volume and play a melody every 15 min utes until the...

Страница 13: ...he functionality shifts with the power level of the battery Battery level Signal Hearing aid Remote Control Streaming Fully charged P P P Low P P O Depleted change battery P O O 400846011US 17 10 Rev...

Страница 14: ...tioned correctly in the ear Opening and closing your mouth can ease insertion 4 Make sure the hearing instrument is seated behind the ear By experimenting an easier method may be discovered With prope...

Страница 15: ...the receiver tube sticking out when facing a mirror iNote You should never attempt to bend or modify the shape of the receiver tube Removal RIE molds 1 Grasp the removal string and pull the RIE or UP...

Страница 16: ...ur different listening programs each of them suitable for certain situations Multi function button 62 models only Your hearing care professional can fill out the following table for you Program Descri...

Страница 17: ...you have two hearing instruments with the synchronization function enabled program changes to one instrument will automatically repeat in the second instrument When a program change is made in one in...

Страница 18: ...instrument will follow The multi function button is designed to change the volume or listening programs of the hearing instrument based on different ways it is pressed If necessary your hearing care p...

Страница 19: ...aring instrument is in flight mode the hearing instrument must have been operating in flight mode for at least 10 seconds before attempting to enable wireless again It is possible to re enable wireles...

Страница 20: ...d one or more of the following suggestions may be helpful 1 Hold the telephone as you would normally 2 Hold the telephone towards the top of the ear closer to where the microphones are located 3 If wh...

Страница 21: ...in pairing and using these products with your Truhearing Flyte device please contact your hearing care professional or visit our support site at www userguides gnhear ing com Cellular phones Your hea...

Страница 22: ...eceiver Make sure not to cover the microphone openings If necessary move the magnet to another position to improve ease of use and comfort while speaking 4 If you are not satisfied with the strength o...

Страница 23: ...rding appropriate safety precautions when using your hearing instrument and magnet in close proximity to the medical device or electronic system in question If the manufacturer cannot issue a statemen...

Страница 24: ...sound is picked up directly and may improve speech understanding If there is no sound from the hearing instruments in a tele loop system and with a telecoil program activated the tele loop system may...

Страница 25: ...nd below the model number 2 Once in place move the boot in the direction of the battery compartment 3 Gently click the audio boot onto the hearing instrument Disconnecting audio boots 4 Press and hold...

Страница 26: ...to remove grease or moisture 4 Do not wear your HAs when putting on cosmetics perfume after shave hair spray suntan lotion etc These might discolour the HA or get into the HA causing damage 5 Do not i...

Страница 27: ...ily maintenance It is important to keep your hearing instrument clean and dry On a daily basis clean the hearing instruments using a soft cloth or tissue 400846011US 17 10 Rev A indd 27 02 10 2017 14...

Страница 28: ...should be cleaned regularly Use a damp cloth to clean the re ceiver tube and receiver dome on the outside Do not use water when you are cleaning the receiver tubes or the receiver domes This process...

Страница 29: ...that the shaft of the tool is touching the rim of the wax guard Slowly pull the wax guard straight out 2 To insert the new wax guard gently press the replacement side of the wax guard tool straight in...

Страница 30: ...Tulip domes Tulip domes are mounted in a similar manner to standard domes but a few extra steps are required Tulip domes consist of two petals It is important to note that the largest petal is the out...

Страница 31: ...ices If you would like a printed version of the user guide for a smart phone app please consult customer support iGeneral precautions 1 When wireless function is activated the device uses low powered...

Страница 32: ...s to use your hearing aids This may cause damage to the hearing of the other individual or to the hearing aids 6 Hearing aid usage by children or mentally disabled persons should be supervised at all...

Страница 33: ...GN Hearing wireless devices operate in the frequency range of 2 4 GHz 2 48 GHz GN Hearing wireless devices include a RF transmitter that operates in the range of 2 4 GHz 2 48 GHz For use of wireless f...

Страница 34: ...continuous or fluctuating humming User instructions for the TSG module Description of the device The Tinnitus Sound Generator TSG Module is a software tool that generates sounds to be used in tinnitu...

Страница 35: ...lthcare professional will review with you the need for having such a control For hearing aids where ear to ear synchronisation is enabled your hearing healthcare professional can also enable environme...

Страница 36: ...e TSG module provides sound enrichment with the aim of surrounding the tinnitus sound with a neutral sound which is easily ignored Sound enrichment is an important component of most approaches to tin...

Страница 37: ...an be shaped with the following configurations The white noise signal can be modulated in amplitude with an attenuation depth of up to 14dB High pass filter Low pass filter 500 Hz 2000 Hz 750 Hz 3000...

Страница 38: ...rceived decrease in auditory function or increase in tinnitus perception the user should discontinue use of the sound generator and seek medical evaluation Children and physically or mentally challeng...

Страница 39: ...te or chronic dizziness v Unilateral hearing loss of sudden or recent onset within the previous 90 days vi Audiometric air bone gap equal to or greater than 15dB at 500 hertz Hz 1000 Hz and 2000 Hz vi...

Страница 40: ...local regulations or return them to your hearing care practitioner 4 DO NOT place batteries in your mouth Consult a physician immediately if a battery has been swallowed as they can be harmful to your...

Страница 41: ...anic conditions Consistent use of the hearing instrument is recommended In most cases infrequent use does not permit you to attain full benefit from it The use of a hearing instrument is only part of...

Страница 42: ...dden or recent onset within the previous 90 days vi Audiometric air bone gap equal to or greater than 15 decibels at 500 hertz Hz 1 000 Hz and 2 000 Hz vii Visible evidence of significant cerumen accu...

Страница 43: ...hearing aid for a period of time for a nominal fee after which you may decide if you want to purchase the hearing aid Federal law restricts the sale of hearing aids to those individuals who have obta...

Страница 44: ...ll not close Blocked RIE mold or tube Blocked wax filter Not loud enough Incorrect RIE mold placement Blocked RIE mold or dome Change in hearing sensitivity Excessive ear wax Volume set too low Troubl...

Страница 45: ...mold or tube Replace wax filter or consult your hearing care professional Reinsert RIE mold Clean RIE mold replace dome replace filter Consult your hearing care professional Consult your hearing care...

Страница 46: ...nt RIE mold tubing worn or damaged Hearing instrument settings not optimal Sound distorted not clear Weak battery Improper RIE mold or dome fit Hearing instrument damaged Hearing instrument settings n...

Страница 47: ...l Replace battery Consult your hearing care professional Consult your hearing care professional Consult your hearing care professional Open and close the battery compartment once Wireless will reactiv...

Страница 48: ...N 45605 100 7060 Hz Current drain in test mode 1 3 mA RIE LP receiver Models FL962 DRW LP FL762 DRW LP FP962 DRW LP FP762 DRW LP Frequency Hz FULL ON AND REFERENCE TEST GAIN Gain dB Reference test gai...

Страница 49: ...1 2 Telecoil sensitivity SPLIV 31 6 mA m 96 dB SPL Equivalent input noise w o noise reduction 23 dB SPL Frequency range DIN 45605 100 7000 Hz Current drain in test mode 1 3 mA RIE MP receiver Model F...

Страница 50: ...range DIN 45605 100 6030 Hz Current drain in test mode 1 3 mA RIE HP receiver Model FL962 DRW HP FL762 DRW HP FP962 DRW HP FP762 DRW HP Frequency Hz Gain dB Reference test gain 60 dB SPL input Full o...

Страница 51: ...range DIN 45605 100 4910 Hz Current drain in test mode 1 2 mA RIE UP receiver Model FL962 DRW UP FL762 DRW UP FP962 DRW UP FP762 DRW UP Frequency Hz Gain dB Reference test gain 60 dB SPL input Full o...

Страница 52: ...instruments is designated on your warranty card which is provided by your hearing care professional For hearing instruments that require service please contact your hearing care professional for assis...

Страница 53: ...h 6th generation and iPod touch 5th generation using iOS 8 X or later Apple the Apple logo iPhone iPad Pro iPad Air iPad mini iPad and iPod touch are trademarks of Apple Inc registered in the U S and...

Страница 54: ...400846011US 17 10 Rev A indd 54 02 10 2017 14 48 15...

Страница 55: ...400846011US 17 10 Rev A indd 55 02 10 2017 14 48 15...

Страница 56: ...g A S 8001 E Bloomington Freeway Bloomington MN 55420 1036 400846011US 17 10 Rev A Distributed by TruHearing Inc 12936 S Frontrunner Blvd Draper UT 84020 USA 844 278 8672 400846011US 17 10 Rev A indd...

Отзывы: