![Trufrost YC-150EW Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/trufrost/yc-150ew/yc-150ew_operation-manual_1175721015.webp)
15
7.6 Condensation Draining
After using the product for a period of time, there may be condensed water formed at the bottom of
the chamber, please drain away the condensed water in time to avoid damaging the storage items
such as vaccines.
①
As shown in the picture, the drain has an external plug ''2'' and an internal plug ''3''.
②
Before the draining, pls prepare a water box ''1''. Taking out the plugs ''2'' and ''3'' to discharge
the condensed water.
③
Install the plugs back after the draining, otherwise the performance will be damaged.
7.7 Steps to replace the fuse
①
Find the fuse seat from the bundling wire harness of the wiring row and unscrew the fuse seat.
②
Take out the fuse: the fuse is showed on the picture as below.
③
Put in the new fuse and tighten the fuse seat.
④
Ten spare fuses are placed in the enclosure bag inside the equipment.