![Trufrost YC-150EW Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/trufrost/yc-150ew/yc-150ew_operation-manual_1175721014.webp)
14
①
Regarding to the units which are not in the operation for a long time.It is better to make products
running for more than 24 hours per month to charge to prolong the service life of the battery.
②
If the equipment is not used for a long time, it should be regularly (usually once a month) turned
on power and opened the power supply switch lock to run and charge, with not less than 24 hours
each time.
③
When the power supply is interrupted, turn off the power lock switch of the equipment in time,
otherwise the battery will lose power and cause permanent damage to the battery;
④
The main power switch must be turned off when there is long-term power failure or in
transportation , otherwise the battery will lose power or even permanent damage due to a long time
of discharge, and the display will be not normal after power is on again :
⑤
The battery is consumable and has a life of about 2 years. If the battery is not properly used,
such as loss of power or reach the service life, it will cause low battery power alarm (it does not
affect the refrigeration but there is an alarm fault and impact the power failure alarms, please
contact our after-sales service personnel for replacement).
Battery replacement
①
Turn off the power switch and pull the power plug from the socket;
②
Remove the electrical box screws with a screwdriver; (
Note
: There are high-voltage electrical
components in the electrical box. Before opening, the power supply must be turned off, the power
plug must be unplugged and the power lock switch of the equipment must be turned off. The
electrical box must be opened by qualified engineers or maintenance personnel.)
③
Unplug the battery connect wire; (Note: Before unplugging the battery fixed wire, please record
the wiring order of battery positive and negative. When change new battery, pay attention to the
correct wiring order in case of burning out control system due to wrong connecting. Generally, the
red wire is connected to the battery positive , and the black wire is connected to the negative.
④
Remove the fixing screw from the battery fixing plate with a screwdriver and remove the battery;
⑤
Battery model
:
DC-2600mAh-AG(3.7V) .
7.4 Disposal
Dumped Battery should be recycled and turn to local relevant administration department.Follow the
relevant laws and regulations of the host country and 2002/ 96/ EC.
Tips
: In order to ensure that the battery replacement meets the requirements of the control system
and avoid the influence of improper operation on the system, please contact our after-sales
personnel for replacement or guidance.
7.5 Scrap and process management of the equipment
Caution
:
If the equipment is stored in an unsupervised area for a long time and is not used, it should be
ensured that children will not get close to the equipment and the door cannot be completely closed.