Trufrost YC-150EW Скачать руководство пользователя страница 14

14

Regarding to the units which are not in the operation for a long time.It is better to make products

running for more than 24 hours per month to charge to prolong the service life of the battery.

If the equipment is not used for a long time, it should be regularly (usually once a month) turned

on power and opened the power supply switch lock to run and charge, with not less than 24 hours

each time.

When the power supply is interrupted, turn off the power lock switch of the equipment in time,

otherwise the battery will lose power and cause permanent damage to the battery;

The main power switch must be turned off when there is long-term power failure or in

transportation , otherwise the battery will lose power or even permanent damage due to a long time

of discharge, and the display will be not normal after power is on again :

The battery is consumable and has a life of about 2 years. If the battery is not properly used,

such as loss of power or reach the service life, it will cause low battery power alarm (it does not

affect the refrigeration but there is an alarm fault and impact the power failure alarms, please

contact our after-sales service personnel for replacement).

Battery replacement

Turn off the power switch and pull the power plug from the socket;

Remove the electrical box screws with a screwdriver; (

Note

: There are high-voltage electrical

components in the electrical box. Before opening, the power supply must be turned off, the power

plug must be unplugged and the power lock switch of the equipment must be turned off. The

electrical box must be opened by qualified engineers or maintenance personnel.)

Unplug the battery connect wire; (Note: Before unplugging the battery fixed wire, please record

the wiring order of battery positive and negative. When change new battery, pay attention to the

correct wiring order in case of burning out control system due to wrong connecting. Generally, the

red wire is connected to the battery positive , and the black wire is connected to the negative.

Remove the fixing screw from the battery fixing plate with a screwdriver and remove the battery;

Battery model

DC-2600mAh-AG(3.7V) .

7.4 Disposal

Dumped Battery should be recycled and turn to local relevant administration department.Follow the

relevant laws and regulations of the host country and 2002/ 96/ EC.

Tips

: In order to ensure that the battery replacement meets the requirements of the control system

and avoid the influence of improper operation on the system, please contact our after-sales

personnel for replacement or guidance.

7.5 Scrap and process management of the equipment

Caution

:

If the equipment is stored in an unsupervised area for a long time and is not used, it should be

ensured that children will not get close to the equipment and the door cannot be completely closed.

Содержание YC-150EW

Страница 1: ...MANUAL YC 150EW WHO PQS certificate report No 1911 16528 WB 19 331 PQS Independent type testing protocol WHO PQS E003 RF03 VP 3 PQS performance specification WHO PQS E003 RF03 4 Issuing date 2020 3 25...

Страница 2: ...2 Better science Better life www trufrostbiomedical com info trufrost com...

Страница 3: ...tor Components 10 6 Display panel function description 10 6 1 Function introduction 10 6 2 Function setting 12 7 Maintenance 13 7 1 Maintenance 13 7 2 Out of use 13 7 3 Maintenance 13 7 4 Disposal 14...

Страница 4: ...n or use it is not allowed to vibrate or collide violently or get wet Please store in a well ventilated and clean room with humidity less than 95 no corrosive gas Ice lined refrigerators hereinafter a...

Страница 5: ...n injury from the unit falling or tipping over Carefully with the power cord to avoid short circuit or open circuit When removing the plug from the power supply outlet grip the power supply plug not t...

Страница 6: ...s goods strong corrosive acid alkali and other articles not suitable in the equipment When storing toxic harmful or radioactive materials please use this equipment in a safe area Improper use may harm...

Страница 7: ...g value and condensation will appear around the outside of the through hole Please use a diluted neutral cleaner to clean the equipment and do not use brushes acid gasoline soap powder polishing agent...

Страница 8: ...n 4KW to ensure reach the input voltage requirements Be sure to ground the unit If the power cord socket is equipped with grounding wire check the connection before use If the power supply outlet is n...

Страница 9: ...lay temperature and the set temperature of the equipment which is a normal The equipment is for storage which can not be used for routine production It is strictly prohibited to put too many relativel...

Страница 10: ...refrigerators with battery excluding Lead mercury chromium benzene ether 6 Display panel function description 6 1 Function introduction The electronic digital display can display the actual temperatur...

Страница 11: ...ing state Mute operation When the buzzer alarms including over temperature alarm inside the cabinet sensor fault alarm etc press the mute button for the first time when the key is locked and the buzze...

Страница 12: ...ameter 3 can successfully open the precooling mode Note The high temperature alarm will be triggered when the machine is started for the first time Please put in the items after the temperature is sta...

Страница 13: ...use hot water corrosive cleanser and organic solvent DO NOT place heavy objects on the top of the equipment to avoid deformation under pressure 7 2 Out of use Out of use If the equipment is stored in...

Страница 14: ...ews with a screwdriver Note There are high voltage electrical components in the electrical box Before opening the power supply must be turned off the power plug must be unplugged and the power lock sw...

Страница 15: ...ernal plug 3 Before the draining pls prepare a water box 1 Taking out the plugs 2 and 3 to discharge the condensed water Install the plugs back after the draining otherwise the performance will be dam...

Страница 16: ...ient temperature is too high Loud noise Freezer is not leveled well Freezer leans upon the wall Surface condensation of glass door Wet and moisture season the door may be condensed It belongs to norma...

Страница 17: ...for any fault or damage caused by improper use Storing environment temperature 30 70 Relative humidity 5 95 9 Specifications Main technical parameters The foaming agent is cyclopentane Main performan...

Страница 18: ...ronic Co Ltd R series 250 V 16 4 A 10E3 T85 VDE 40000809 Battery Dongguan Xintongtai Industrial Co Ltd 18650 3 7V 2600mAh 9 62Wh Tested with appliance If the product is improved the technical data and...

Страница 19: ...the world including remote areas with poor weather and storage conditions and high humidity The packaging has an edge crushing resistance of not less than 17kN and maintains at least 60 edge crushing...

Страница 20: ...or temperature controller evaporator solenoid valve condenser main control panel electronic control display defrosting timer temperature sensor defrosting heater 3 The following cases are not within t...

Страница 21: ...ing receipt Dear users Thank you for choosing Trufrost brand products Please fill out this card and send it back to our company We will establish the user file for you in time Thank you for your coope...

Страница 22: ...eted globally by TRUFROST COOLING PRIVATE LIMITED 1215 12th Floor Tower B Emaar Digital Greens Golf Course Extn Road Sector 61 Gurugram 122011 T 91 7303166766 info trufrost com www trufrostbiomedical...

Отзывы: