3-199 SERIAL FUNCTION LIST
At power-up, the Serial Port outputs time once per second as described in Function F08 until it receives
a CTRL-C character (Hex 03). Then any of the following commands may be used:
POWER-UP
FUNCTION
DESCRIPTION AS SHIPPED DEFAULT
F01
Time Zone Entry/Request
00
Last Entry
F02
12/24 Hour Format Entry/Request
24
Last Entry
F03
Time/Date Entry/Request
--
--
F05
Time Quality Enable/Setup
On
Last Entry
F06
Keypad Lockout Enable
Off
Last Entry
F07*
External Oscillator Enable
Off
Last Entry
F08
Continuous Time Once/Second Enable
On
On
F09
Time on Request Enable
Off
Off
F11
Time Output Format Entry/Request
DDD:HH:MM:SS.mmmQ
Last Entry
F13
Worst-case Time Error Request
--
--
F14*
Ext Osc Parameter Entry/Request
--
Last Entry
F15
Exclusive Use Enable
Off
Off
F17*
Slow Code Setup
2,4,6 sec.
Last Entry
F18
Software Version Request
--
--
F26*
Programmable Pulse Output
see function
Last Entry
F28*
Time Interval/ Event Timing Input
Off
Off
F29*
Frequency Measurement Input
Off
Off
F50
Position Entry/Request
Santa Rosa, CA
Last Calc.
F51
Antenna Cable Delay Entry/Request
60 ns
Last Entry
F52
Distribution Cable Delay Entry/Request
0 ns
Last Entry
F53
Operational Mode Entry/Request
AUTO
Last Entry
F55
Altitude Units Entry/Request
Meters
Last Entry
F56
Average Position Entry/Request
N 00d00’0.0” E 000d00’0.0”
Last Calc.
F60
Satellites List Request
--
--
F65
Satellite Select
All
Last Entry
F66
Daylight Saving Enable
Off
Last Entry
F68
Year Entry (GPS Epoch Management)
--
Last Entry
F69
Select Local/Standard/GPS/UTC Time
UTC
Last Entry
F71
Oscillator Statistics Request
--
Last Calc.
F72
Fault Status Request
--
--
F73
Request/Set Alarm Status/Control
see function
Last Entry
F79
Warm Start
--
--
* Optional function
3-200 reserved