STEP 1: DIAGNOSIS
(Check if battery has connected with the charger and also check
battery voltage)
STEP 2: DESULPHATION
(If battery voltage is too low, programs automatically
generate pulsing current to remove sulphate,
up to 5 hours
)
STEP 3: ANALYSE
(Check if the battery voltage reaches to the threshold after
desulphation, and charging begins if the battery voltage is OK)
STEP 4: SOFT START
(Charge with echelon constant current)
STEP 5: BULK
(Charge with constant maximum current until battery voltage is reached
to the threshold)
STEP 6: ABSORPTION
(Provide gradually declining current charge for maximum
battery voltage)
STEP 7: ANALYSE
(Test if the battery can hold charge)
STEP 8: MAINTENANCE
(Continuously monitor the battery, and charging current will
intelligently adapt to the variable battery voltage)
BATTERY LEVEL INDICATOR
LED
Explanation
25%
The 25% Charge Red LED will slowly flash when the battery
level is less than 25%. When 25% is reached, the LED will be
solid.
50%
The 50% Charge Red LED will slowly flash when the battery
level is less than 50%. When 50% is reached, the LED will be
solid.