3.6.3 Installing a Gravity Fed Cup Assembly (Compressed Air Only)
1. Locate the cap (#11, page 33) that blanks the unused material connection and make
sure that it is installed onto the bottom material connection (#29, page 33).
2. Screw the top feed cup to the top material connection (#30, page 33). You are now
ready to spray.
3. Sometimes when spraying heavy materials cup pressure is
required. Attach the cup air pressure regulator to the bottom of the
spray gun handle.
4. Connect one end of the air hose to the cup air pressure regulator.
5. Connect the other end of the air hose to the brass nipple in the top of the cup lid. Be sure that the black half of the valve
is facing toward the cup.
Содержание Apollo 7500 AtomiZer
Страница 32: ...8 Diagram Parts List...