ASSEMBLY STEPS:
Step 8 (Pulley Assembly):
Assemble the pulleys using the
hardware identified as shown
below.
Before assembling the pulley
hardware, make sure that the
cable is seated in the pulley
groove.
Item Part Number
Description
Quantity
1
B 900
PULLEY, 4-1/2” W/ 1/4” GROOVE
4
2
C 766A
NYLON LOCKNUT 3/8-16 x 17/64
2
3
C 626
SHCS 3/8”-16 x 1-3/4”
2
6
C 754C
Washer 3/8” I.D x 3/4” O.D X .065” THK
6
ASSEMBLY STEPS:
Step 9 (Weight Stack and Top Cap Selector Bar):
Insert the guide rods into the designated
holes in the upright assembly.
Place the weight bumper, weight stack
spacer, and weight plates on to the guide
rods in the order shown below.
Assemble the cable end to the weight
top plate and place on to the guide rods
as shown below.
Assemble the guide rods to the upright
assembly using the identified hardware.
Item
Part Number
Description
Quantity
1
FUS-00GR001
SHORT GUIDE ROD
2
2
FUS-00WB001
FUS WT BUMPER
2
3
C 757A
WEIGHT STACK SPACER
2
4
S 501
WEIGHT PLATE
16
5
FUS-00TP016XBK FUSE 16 WT TOP PLATE
ASSY
1
6
XL2-00PN000
SELECTOR PIN ASSY
1
9
C 417
HH SCREW, 1/4”-20,
2-1/2”
2
11
C 740A
NYLON LOCK NUT 1/4”-
20 x 5/16”
2
13
C 752
Washer 1/4” I.D x 1/2” O.D
X .049” THK
4
Truefitness.com / 800.426.6570 / 636.272.7100
40
CHAPTER 4: CARE & MAINTENANCE
CABLE INSPECTION & MAINTENANCE (continued):
Cable Tension:
Ensure that the cables are adjusted to remove any slack using the threaded end fittings. These are normally located at the
weight stack connection. Depending upon the machine, there may be multiple threaded fitting on multiple cables. You
can determine if there is too much slack by performing the exercise. As you start to move a load arm or handle, the weight
stack should lift immediately. If not, the cable tension needs to be adjusted.
To adjust the cable tension, loosen the cable nut
that is located on the
c
able
b
olt connected to the
t
op
p
late. Tighten the cable bolt until the top plate
is barely lifted off of the first weight plate and then
re-tighten the cable nut.
CAUTION:
A minimum of 1/2 inch (12.7mm) of the threaded
portion of the cable bolt must be threaded into the
top plate.
*No
m
ore than 1 inch (
25.4
mm) of the t
h
readed
portion of the cable bolt should be visible
.
Handle Fittings (if applicable):
Inspect the cable fittings where any handles are
attached to the end of the cable. The fittings supplied
with this machine are load rated snap-links. Ensure
that the snap-link opens and closes easily and is fully
engaged when closed. Replace the snap-link as
needed.
Cable Bolt
Cable Nut
Top Plate
1” (
25
.4
mm)
Maximum