5. Place 4th log as shown in (Figure 47). The  

black charcoal side of the piece must  

face inwards. This log will act as a support  

for the final log.

6. Place 5th log as shown in (Figure 48)  

  making sure that the log does not  

  cover the holes of the back row of  

  the burner. 

4.  Position 3rd log as shown in (Figure 46) making  

  sure that the log does not cover the holes of  

  the back row of the burner. 3rd log has a hole  

  in its underside which will fit onto a protruding  

  tab on the burner (Figure 42).

Installer Information

Figure 46:  3rd log placement.

Figure 47:  4th log placement.

Figure 48:  5th log placement.

Содержание TN24

Страница 1: ...DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Leave the building immediately Immediately call your gas supplier from a...

Страница 2: ...5 Vent terminal clearance 16 Vent terminal minimum clearances 16 TN24 Co Axial venting chart 17 TN24 Co Linear venting 18 Venting components 19 TN24 Gas stove rear components 20 Gas and electrical con...

Страница 3: ...above grade directly in line with the exhaust vent terminal for the horizontally vented gas fuelled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in...

Страница 4: ...OR YOUR SAFETY Do not install or operate your Pacific Energy gas stove without first reading and understanding this manual Any installation or operational deviation from the following instructions voi...

Страница 5: ...burns A physical barrier is recommended if there are at risk individuals in the house To restrict access to a gas stove or fireplace install an adjustable safety gate to keep toddlers young children...

Страница 6: ...ire Safety Criteria for Manufactured Home Installations Sites and Communities ANSI NFPA 501A in the USA Installation Requirements The TN24 Gas Stove installation and venting must conform to the curren...

Страница 7: ...e Control with LCD Display The Proflame Remote Transmitter uses a streamline design with a simple button layout and informative LCD display Figure 1 The remote transmitter is powered by 3 AAA type bat...

Страница 8: ...on the Remote transmitter The Remote transmitter LCD display will only show the room temperature Figure 3 or Figure 4 At the same time the Receiver module will turn off the gas stove A single beep fr...

Страница 9: ...To adjust the set point press the up or down arrow keys until the desired set point temperature is displayed on the LCD screen of the remote transmitter Smart Thermostat Transmitter Operation The Smar...

Страница 10: ...ure 1 to index to the CPI mode icon Figure 15 Pressing the Up Arrow Key will activate the Continuous Pilot Ignition mode CPI Pressing the Down Arrow Key will return to IPI Figure 16 A single beep will...

Страница 11: ...are low a double beep will be emitted from the IFC module when it receives a command from the remote This is an alert for a low battery condition for the IFC board When the batteries are replaced a s...

Страница 12: ...tive media such as logs and embers Inspect decorative media and burner assemblies for soot buildup If excessive buildup of soot is present have a qualified service person inspect and adjust unit for p...

Страница 13: ...13 5055 48 A 170915 44 TN24 BODYA Lighting Instructions Owners Information Figure 20 True North lighting instructions...

Страница 14: ...YA Installer Information TN24 Gas Stove Dimensions Dimensions Hight 29 11 16 inches Width 25 inches Depth 19 3 16 inches Height to center of Flue Outlet 24 inches 19 3 16 29 11 16 25 24 17 3 4 24 Figu...

Страница 15: ...enting Vertical venting 4 4 1 4 Locating the Gas Stove 0 4 16 front 4 18 MIN Note on corner placement Refer to minimum clearances as shown in Figure 22 Figure 23 Refer to Figure 24 venting allowances...

Страница 16: ...arance under veranda porch deck or balcony a vent shall not terminate directly above a side walk or paved driveway which is located between two single family dwellings and serves both dwellings only p...

Страница 17: ...ual combination of elbows reduce horizontal vent run by 2 feet Ensure vent pipe is properly supported Damper Note The damper position is factory set to the closed position Every venting configuration...

Страница 18: ...ing codes Intake Air Exhaust Air Simpson Duravent High Wind cap style Co Linear Kit w Flex 46DVA CL34 or Simpson Duravent Prairie cap style Co Linear Kit w Flex 46DVA CL34P are recommended for use wit...

Страница 19: ...t Temp DuraVent DirectVent Pro Galvanize d Black Galvanized Black Galvanized Black Galvanized Black Galvanized Black 6 Pipe Length 4DL6 4DL6B 4D6 4D6B SV4L6 SV4LB6 4DT 06 4DT 06B 46DVA 06 46DVA 06B 9...

Страница 20: ...venting for this gas stove See charts on page 19 for a list of approved venting components TN24 Gas Stove rear components Left blower fan IFC Module Right blower fan Battery bay Electrical connection...

Страница 21: ...en in Figure 32 See Gas Supply on page 32 of this manual for gas supply requirements Electrical connection An IEC power cord is provided for connection to a standard wall outlet Note Do not plug the p...

Страница 22: ...cessed Screen mesh removal 1 Remove the top cover as shown in Figure 34 2 Raise the screen mesh cover as shown in Figure 35 and lift the screen mesh out Figure 36 Glass door removal Glass door retaine...

Страница 23: ...an be removed 3 Remove the glass door together with the retainer frame that it is affixed to Log set pieces The large number one log Figure 39 comes wrapped separately from the smaller logs Figure 40...

Страница 24: ...nd log Figure 45 over the post located on the left hand side of the first log indicated by the arrow Once the 2nd log is mounted to the first log position the lower portion of 2nd log so that it is lo...

Страница 25: ...e 48 making sure that the log does not cover the holes of the back row of the burner 4 Position 3rd log as shown in Figure 46 making sure that the log does not cover the holes of the back row of the b...

Страница 26: ...the frame fits into the horizontal slot on the floor of the firebox 2 Align the glass door frame laterally so that its protruding positioning stud Figure 52 fits into the slot in the firebox This will...

Страница 27: ...n place Figure 54 shows the front side of the screen mesh This side must be facing outward once it is in place The screen mesh frame is not square and so it is important that it be oriented the correc...

Страница 28: ...has channels which will secure the top of the screen mesh once the holder is lowered into position Screen mesh Screen mesh Figure 59 shows the screen mesh holder in place with the holder channels keep...

Страница 29: ...place the tray 1 To remove the tray if necessary undo the wing nuts until the tray is able to be lowered onto the floor 2 Unhook the two electrical leads Figure 61 3 A new glass plate slips into posit...

Страница 30: ...TN24 battery bay Figure 65 located on the rear side of the TN24 Figure 68 Install the ON OFF switch cover Figure 66 over top of the battery bay Make sure that the selection switch is on the Remote set...

Страница 31: ...Venturi should be closed when using natural gas and open when using liquid propane Venturi adjustment is accessible through an opening in the rear cover Figure 31 on page 20 Some adjustment may be re...

Страница 32: ...gas stove Consult local and or national building codes before proceeding Gas supply line connection is located on the rear of the gas stove Gas connection accepts a 45 flare fitting Correct gas line d...

Страница 33: ...tip screwdriver 3 Attach pressure gauge to the test ports 4 Turn gas supply back on and test pressures 5 After testing is finished turn off gas supply remove the pressure gauges and retighten the the...

Страница 34: ...e 567 Thread Sealant needs to be applied to the threads of the new orifice to ensure a proper seal when installed To replace the pilot orifice you will need to remove the pilot hood which is held in p...

Страница 35: ...n 4 Retain rubber grommets and plastic bushings Figure 82 for installation of new fan Screw Screws Installation Installation is the reverse of removal Note The two fans are inverse to each other There...

Страница 36: ...hes the firebox side wall Figure 88 4 Repeat previous step to install the second side panel Back panel support 5 Insert the 3 upper baffles by tucking the top part of the baffle over top of the lip as...

Страница 37: ...ocated in the lower right hand corner Figure 95 2 Seat the mesh screen between the tab and the front cladding panel as indicated in Figure 96 If there is no label on the screen mesh refer to Screen me...

Страница 38: ...Removal 1 Remove the mesh screen as described on Screen mesh replacement on page 37 2 Remove the wing nuts Figure 98 holding the glass door retainer frame to the gas stove frame and tilt the glass doo...

Страница 39: ...Complete TN24 CNTTRAY True North Panel Set Painted TN24 PNLSETA True North Burner TN24 BURNA True North Log Set with Embers TN24 LOGSETA True North Blower Right SA 25L 1027 TN24 BLOWR True North Blow...

Страница 40: ...Wiring Diagram Caution Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing LAMP COMFORT FAN...

Страница 41: ...ined when facing the front of the appliance Les c t s droit et gauche se d terminent en se mettant devant l appareil et en lui faisant face For installation as free standing appliance only Pour l inst...

Страница 42: ...42 5055 48 A 170915 44 TN24 BODYA...

Страница 43: ...43 5055 48 A 170915 44 TN24 BODYA...

Страница 44: ...LTD Reproduction adaptation or translation without prior written permission is prohibited except as allowed under the copyright laws For technical support please contact your retailer Web site www pa...