Installer Information
TN24 Co-Linear Venting
1.
Measure chimney height, cut fl ex liner (min.10’
to termination) as required. Mark one pipe at
both ends to identify combustion air intake pipe
from fl ue outlet pipe.
2.
Attach marked fl ex liner pipe to the intake side
of vent terminal. Seal and secure with sealant
and screws provided. Attach the other pipe
to the outlet side of vent terminal. Seal and
secure with sealant and screws provided.
3.
Insert both fl ex liners from top of the chimney,
down through the damper opening.
4.
Before attaching vent terminal to top of chimney,
apply a bead of caulking to top of clay liner. Slip
vent terminal over liner and secure in place with
lateral retaining bolts.
5.
For larger chimneys, fl ashing will need to be
constructed according to local building codes.
Intake
Air
Exhaust
Air
Simpson Duravent High-Wind (cap style) Co-Linear
Kit w/Flex (46DVA-CL34) or Simpson Duravent Prairie
(cap style) Co-Linear Kit w/Flex (46DVA-CL34P) are
recommended for use with this appliance.
Visit http://www.duravent.com for kit details.
NOTE:
If venting the TN24 through an existing
fi replace opening using a co-axial to co-linear
adapter, the customer will have a couple of
aesthetic options which include:
1.
sealing up the existing fi replace opening
with a cover or other material, leaving
room in the cover or other material to
accomodate the adapter so that it is
positioned fl ush (Figure 27) with the cover
or other material.
2.
Positioning the TN24 so that it and
the adapter are located outside of the
existing fi replace opening.
Co-Linear Venting Notes:
•
TN24 requires a 3 inch
diameter exhaust vent
and a 3 inch intake
vent.
•
Max. Vent Height 35’
(15.25M) to termination
•
Min. Vent Height 10’ (3m)
to termination.
High wind cap
Prairie cap
Figure 27: True North 24 co-linear venting
confi guration.