True Manufacturing Company TAC-14GS-HC-LD Скачать руководство пользователя страница 4

TEC_TM_086 REV. B | EN

09/26/22

Page 4 of 24

AIR CURTAIN

www.truemfg.com

Prior to Installation

Ownership

To ensure that your unit works properly from the first day, it must 
be installed properly. We highly recommend a trained refrigeration 
mechanic and electrician install your TRUE equipment. The cost of 
a professional installation is money well spent.
Always carefully inspect for freight damage before receiving and 
installing your appliance. If there is damage, note all damage on 
the delivery receipt, immediately file a claim with the delivery 
freight carrier, and contact TRUE. DO NOT INSTALL THE UNIT OR 
PUT IT IN SERVICE.

TRUE is not responsible for damage incurred during 
shipment.

Cabinet Specification

This appliance is rated for the storage and/or display of 
prepackaged or bottled food product. 

Cabinet Location

•  Appliance tested for IEC to ISO Climate Class 8 [75°F (24°C) 

temperature, 55% relative humidity].

•  For proper operation, ambient temperatures shall not be 

less than 60°F (15.5°C) and no greater than 75°F (24°C), or as 
indicated on the serial label.

•  Appliance is not suitable for outdoor use.
•  Appliance is not suitable for an area where a pressure washer or 

hose may be used.

•  Ensure the location will provide adequate clearances and 

sufficient airflow for the cabinet.

•  Under extreme heat conditions [greater than 100°F (38°C)], you 

may want to install an exhaust fan.

•  Ensure the power supply for the cabinet matches the cabinet 

specification sheet or cabinet data plate and is within the 
rated voltage (+/-5%). Also, that the amp rating of the circuit is 
correct and that it is properly grounded.

•  The cabinet should always be plugged into its own individual 

dedicated electrical circuit. The use of adapter plugs and 
extension cords is prohibited.

Notice to Customer

Loss or spoilage of products in your 
refrigerator/freezer is

 not covered by 

warranty

. In addition to following 

recommended installation procedures, you 
must run the refrigerator/freezer for 24 hours 
prior to usage to verify its proper operation.

Wire Gauge Chart

CLEARANCES

TOP

SIDES

BACK

TAC

8" Open (203.2 mm)

0" (0 mm)

3" (76.2 mm)

WARNING

 

– Warranty is void if ventilation is insufficient.

Table 2.6. Wire gauge chart (115V)

115

Volts

Distance In Feet To Center of Load

AMPS

20

30

40

50

60

70

80

90

100

120

140

160

2

14

14

14

14

14

14

14

14

14

14

14

14

3

14

14

14

14

14

14

14

14

14

14

14

12

4

14

14

14

14

14

14

14

14

14

12

12

12

5

14

14

14

14

14

14

14

12

12

12

10

10

6

14

14

14

14

14

14

12

12

12

10

10

10

7

14

14

14

14

14

12

12

12

10

10

10

8

8

14

14

14

14

12

12

12

10

10

10

8

8

9

14

14

14

12

12

12

10

10

10

8

8

8

10

14

14

14

12

12

10

10

10

10

8

8

8

12

14

14

12

12

10

10

10

8

8

8

8

6

14

12

12

12

10

10

10

8

8

8

6

6

6

16

12

12

12

10

10

8

8

8

8

6

6

6

18

12

12

10

10

8

8

8

8

8

8

8

5

20

12

12

10

10

8

8

8

6

6

6

5

5

25

10

10

10

8

8

6

6

6

6

5

4

4

30

10

10

8

8

6

6

6

6

5

4

4

3

Table 2.7. Wire gauge chart (230V)

230

Volts

Distance In Feet To Center of Load

AMPS

20

30

40

50

60

70

80

90

100

120

140

160

5

14

14

14

14

14

14

14

14

14

14

14

14

6

14

14

14

14

14

14

14

14

14

14

14

12

7

14

14

14

14

14

14

14

14

14

14

12

12

8

14

14

14

14

14

14

14

14

14

12

12

12

9

14

14

14

14

14

14

14

14

12

12

12

10

10

14

14

14

14

14

14

14

12

12

12

10

10

12

14

14

14

14

14

14

12

12

12

10

10

10

14

12

12

12

12

12

12

12

12

10

10

10

8

16

12

12

12

12

12

12

12

10

10

10

8

8

18

12

12

12

12

12

12

10

10

10

8

8

8

20

12

12

12

12

10

10

10

10

10

8

8

8

25

10

10

10

10

10

10

10

10

8

8

6

6

30

10

10

10

10

10

10

8

8

8

6

6

6

Содержание TAC-14GS-HC-LD

Страница 1: ...elatam truemfg com 9 00 am 5 30 pm M F UK Ireland Middle East Africa and India Phone 44 0 800 783 2049 service emea truemfg com 8 30 am 5 00 pm M F European Union and Commonwealth of Independent State...

Страница 2: ...eveling 9 Sealing the Cabinet to the Floor 9 Electrical Safety 9 Cabinet Setup Shelving 10 Flavor Strip Installation 13 Cabinet Operation Startup 14 Temperature Control Location 14 General Sequence of...

Страница 3: ...aerosol cans with a flammable propellant in this appliance Keep fingers out of the pinch point areas clearances between the doors and cabinet are necessarily small be careful closing doors when childr...

Страница 4: ...be plugged into its own individual dedicated electrical circuit The use of adapter plugs and extension cords is prohibited Notice to Customer Loss or spoilage of products in your refrigerator freezer...

Страница 5: ...r correct clearance in back of and above the cabinet A 3 77 mm clearance is required at the rear of the cabinet and 8 204 mm clearance above the cabinet Maximum ambient conditions 75 F 23 8 C or as in...

Страница 6: ...the cabinet See fig 2 NOTE Move the unit as close as possible to the final location before removing the wooden skid Some models may require removing the front and or rear grill cover to access the shi...

Страница 7: ...d to secure the cabinet to the skid See figs 1 and 2 Procedure 6 152 mm Leveling Legs 1 Access the bottom of the cabinet and thread the leveling legs into the rail See figs 3 and 4 2 Verify that the c...

Страница 8: ...ltiple shims at 90 angles Fig 7 Install shim s Leveling Shim Lower Rail Assembly Bearing Race Snug Fit Here Rail End Castor Castor Stem HEX NUT SPLIT LOCK WASHER FLAT WASHER TAC 30 36 48 72 RAIL ASSEM...

Страница 9: ...tion 2 Level the cabinet The cabinet should be level side to side and front to back To check that the cabinet is level place a carpenter s level on the interior cabinet floor in four places a Position...

Страница 10: ...helving Installation Cantilever shelves come packaged inside the unit Leg leveling parts may be taped to the top of the shelf packaging See fig 1 Fig 1 Leveling leg parts taped to shelf packaging Fig...

Страница 11: ...bracket on the other side 2 Install the shelves onto the shelf brackets a Position the shelf on the shelf brackets The horizontal bends on the left and right sides of the shelf should be to the outsi...

Страница 12: ...ance from the floor for flat shelves 3 Ensure the shelf clip is not loose or able to wiggle out of the shelf standard See figs 8 and 9 4 Place the shelves on the shelf clips with the cross support bar...

Страница 13: ...helf becomes the front See fig 1 2 With the larger strip opening on the bottom snap the flavor strip onto the shelf See figs 2 3 3 Install tags into the flavor strip See fig 4 B A B Fig 2 Snap the fla...

Страница 14: ...t 5 minutes before restarting RECOMMENDATION Before loading product run your TRUE unit empty for 24 hours to verify proper operation Remember our factory warranty DOES NOT cover product loss ECO C F T...

Страница 15: ...ntrol display may reflect the refrigeration cycle swings of up and down temperatures NOT product temperature The most accurate method to determine a cabinet s operation is to verify the product temper...

Страница 16: ...protection is recommended CAUTION Coil fins are sharp Gloves are recommended Required Tools Procedure 1 Unplug the unit or turn off the power supply 2 Remove the front louver grill See figs 1 3 3 With...

Страница 17: ...30 days or as needed A dirty condenser coil can result in non warranted repairs and or cabinet failure Proper cleaning involves removing dust from the condenser by using a soft brush vacuuming the con...

Страница 18: ...nt Omission of proprietary cleansers from this list does not imply inadequacy 8 Tips to Help Prevent Rust on Stainless Steel Maintain the Cleanliness of Your Equipment Avoid build up of hard stains by...

Страница 19: ...ve a licensed service provider service your unit to minimize the risk of possible ignition due to incorrect parts or improper service and to ensure the operator s health and safety Unplug the refriger...

Страница 20: ...or lower must be obtained All claims for labor or parts must be made directly through TRUE All claims should include model number of the unit the serial number of the cabinet proof of purchase date of...

Страница 21: ...TEC_TM_086 REV B EN 11 8 2022 Page 21 of 24 AIR CURTAIN www truemfg com NOTES...

Страница 22: ...TEC_TM_086 REV B EN 09 26 22 Page 22 of 24 AIR CURTAIN www truemfg com NOTES...

Страница 23: ...TEC_TM_086 REV B EN 11 8 2022 Page 23 of 24 AIR CURTAIN www truemfg com NOTES...

Страница 24: ...11 8 2022 Page 24 of 24 TEC_TM_086 REV B EN www truemfg com BC_197311_9 22...

Отзывы: