Rev C, March 8, 2018 

Manual Number 9019049

 

 

function has been submitted to and reviewed by the FAA along with the TSO-C71 requirements 
and functionality. 

Additionally, there are limitations associated with a derating of the maximum continuous power 
available at the high end of the rated temperature and altitude specification. For more details, 
see Figures 2.1 and 2.2 below. 

The conditions and tests for TSO approval of this article are minimum performance standards. 
Those installing this article, on or in a specific type or class of aircraft, must determine that the 
aircraft installation conditions are within the TSO standards. TSO articles must receive 
additional installation approval prior to being operated on each aircraft. The article may be 
installed only according to 14 CFR Part 43 or the applicable airworthiness requirements. 

 

 

Figure 2.1 – Derated Output Power versus Altitude 

 

 

Figure 2.1 – Derated Output Power versus Temperature 

 

 

0

500

1000

1500

2000

2500

0

5000

10000

15000

20000

25000

30000

35000

40000

Output

 

Power

 

(watts)

Altitude

 

(feet)

Output

 

Power

 

vs

 

Altitude

0

500

1000

1500

2000

2500

60

40

20

0

20

40

60

80

Output

 

Power

 

(watts)

Temperature

 

(°C)

Output

 

Power

 

vs

 

Temperature

Содержание TC2000 Series

Страница 1: ...lectrical Power Converter True Blue Power is a division of Mid Continent Instrument Co Inc Mid Continent Instrument Co Inc dba Mid Continent Instruments and Avionics 9400 E 34th Street N Wichita KS 67226 Manual Number 9019049 PH 800 821 1212 FX 316 630 0723 Rev C March 8 2018 ...

Страница 2: ...nts concerning this manual Although every effort has been made to keep it free of errors some may occur When reporting a specific problem please describe it briefly and include the manual part number the paragraph figure table reference and the page number Send your comments to True Blue Power c o Mid Continent Instrument Co Inc Attn Technical Publications 9400 E 34th Street N Wichita KS 67226 USA...

Страница 3: ...N DETAIL Revision Date Approved Detail A 12 28 2017 BAW Initial release B 01 26 2018 BAW Corrected formatting issues Incorporated FAA comments C 03 08 2018 JRC Changed paragraph 3 3 2 3 pin E to pin A Added note page 5 on ground regulatory requirements ...

Страница 4: ...KING AND INSPECTING EQUIPMENT 8 3 3 CABLE HARNESS 8 3 3 1 Wire Gauge Selection 8 3 3 2 Pin Assignment Information 9 3 3 3 Example Wiring Diagrams 10 3 3 4 Harness Verification 10 3 4 MOUNTING 12 3 5 INSTALLATION COMPLETION 13 3 6 INSTALLATION CAUTION 13 SECTION 4 OPERATION 14 4 1 ELECTRICAL PERFORMANCE 14 4 2 PROTECTIVE FEATURES 14 4 2 1 Remote On Off 14 4 2 2 Over Temperature 14 4 2 3 Short Circu...

Страница 5: ...hort circuit protection overload capability low voltage shut down temperature monitoring a self resettable over temperature disable and a remote on off function The TC2000 Series has a robust Military rated circular connector and the rugged extrusion that houses the unit is designed to help dissipate heat and provide mechanical strength against vibration or other possibilities of damage Two indepe...

Страница 6: ...owever installation locations where the unit could be subject to standing or direct water exposure should be avoided The unit can be mounted in any orientation Clearance should be provided for the mating connector and may require as much as five inches past the unit connector to allow for back shell access to the connector 2 3 ROUTING OF CABLES The wires and cable bundle associated with the unit a...

Страница 7: ...rticle on or in a specific type or class of aircraft must determine that the aircraft installation conditions are within the TSO standards TSO articles must receive additional installation approval prior to being operated on each aircraft The article may be installed only according to 14 CFR Part 43 or the applicable airworthiness requirements Figure 2 1 Derated Output Power versus Altitude Figure...

Страница 8: ...quipment a Mating Connector cable clamp MCI P N 9018993 1 and 9018550 2 Equipment not provided a Mounting Hardware four 4 20 pan head screws lock washers optional b Cable Harness Wire See Section 3 3 for specifications 3 3 CABLE HARNESS Construct the cable harness with regards to the instructions below and using Figures 3 3 3 5 and Wiring Diagram of Table 3 3 Refer to Section 2 Pre Installation Co...

Страница 9: ...ed return bus if it is desirable to have a 28V DC bus independent and isolated from the aircraft DC bus Note Use of a circuit breaker on the DC output is optional For the full output of 2000W a single circuit breaker current of 75 Amp maximum is recommended If multiple branching circuits are connected to the output then the total rating of all circuit breakers should not exceed 75 Amps 3 3 2 3 CON...

Страница 10: ...e than one TC2000 can be connected in parallel to provide more than 2000 Watts of power conversion to 28 VDC Contact Mid Continent Instruments True Blue Power for additional information on this feature If the parallel operation feature is not being used this pin should remain unconnected 3 3 3 Example Wiring Diagrams See Figures 3 4 and 3 5 for examples of potential wiring diagram options for inst...

Страница 11: ... 8 V D C O U T P U T G G F Figure 3 4 Typical TC2000 Aircraft Wiring Installation Constant On T C 2 0 0 0 B B E E A A C C D D 1 1 5 V A C I N P U T 3 0 A C I R C U I T B R E A K E R O F F O N C A S E A T T A C H E D T O A I R F R A M E E N A B L E 7 5 A C I R C U I T B R E A K E R 2 8 V D C O U T P U T G G F Figure 3 5 Typical TC2000 Aircraft Wiring Installation Remote On Off ...

Страница 12: ...s designed for base mounting only in any orientation Four 20 mounting holes should be provided in the aircraft in accordance with Figure 3 6 Secure the unit with four 20 pan head screws or equivalent A lock washer under the head of each screw is recommended 3 75 5 50 13 25 11 75 14 00 4X Ø 0 281 Mounting Holes 3 45 6 32 Figure 3 6 TC2000 Series Static Converter Outline Drawing ...

Страница 13: ...verification Verify the output of the unit at the terminating end of the cable with a multi meter to ensure proper voltage and polarity Once verified installation can be completed and functionality of the remote on off feature if used should be checked 3 6 INSTALLATION CAUTION CAUTION Do not connect the output of the TC2000 Series Static Converter to the output of any other Converter or damage wil...

Страница 14: ...of the unit The unit can be similarly disabled by removing the ground signal open circuit to the same pin 4 2 2 Over Temperature The TC2000 Series Static Converter incorporates an internal temperature sensing device that continually provides monitoring and feedback to the control circuits When the unit senses an internal condition that exceeds maximum temperature ratings the output is disabled and...

Страница 15: ...ude Low Temperature High Temperature Altitude 4 4 5 2 4 5 4 4 6 1 Category C3 Operating Low Temp 55C Operating High Temp 70C Altitude 35 000 ft Temperature Variation 5 Category S2 Humidity 6 Category B Operational Shock and Crash Safety 7 Category B Vibration 8 Category R Curve C C1 RCC1 Explosion 9 Category X Waterproofness 10 Category X Fluids 11 Category X Sand and Dust 12 Category X Fungus 13 ...

Отзывы: