15 Manual Number 9017942 • Revision K, May 14, 2020
SECTION 5 CONFORMANCE
5.1
CONTINUED AIRWORTHINESS STATEMENT
No periodic scheduled maintenance or calibration is necessary for continued airworthiness of the
TA102 series Dual USB Charging Port. If the unit fails to perform to specifications, the unit must be
removed and serviced by Mid-Continent Instruments and Avionics or their authorized designee.
5.2
ENVIORNMENTAL QUALIFICATION STATEMENT
MODEL NUMBER:
TA102 Series
PART NUMBER:
6430102-( )
DESCRIPTION:
Dual USB Charging Port
CERTIFICATION:
FAA TSO-C71
MANUFACTURER:
True Blue Power, a division of Mid-Continent Instrument Co., Inc.
ADDRESS:
9400 E. 34
th
St. North, Wichita, KS 67226, USA.
SPECIFICATION:
Test Specification (TS) 509 Test Data Sheet (TDS) 509
STANDARD
:
RTCA DO-160, Rev G, dated 12/08/10
CONDITIONS
SECTION
DESCRIPTION OF TEST
Temperature and Altitude
4
Category F1
Temperature Variation
5
Category S2
Humidity
6
Category B
Operational Shock and Crash Safety
7
Category B
Vibration
8
Fixed Wing: Category R; Curves C, C1
Rotorcraft: Category U; Curve G
Explosion
9
Category X
Waterproofness
10
Category X
Fluids
11
Category X
Sand and Dust
12
Category X
Fungus
13
Category X
Salt Spray
14
Category X
Magnetic Effect
15
Category Y
Power Input
16
Category B(XX)
Voltage Spike
17
Category B
Audio Frequency Conducted Susceptibility
18
Category R
Induced Signal Susceptibility
19
Category X
Radio Frequency Susceptibility
20
Category X
Emission of Radio Frequency Energy
21
Category M
Lightning Induced Transient Susceptibility
22
Category X
Lightning Direct Effects
23
Category X
Icing
24
Category X
ESD
25
Category A
Fire, Flammability
26
Category C
REMARKS:
Section 4: Category F1 with excursions as declared by the manufacturer:
4.5.2: Operating Low Temp: -40°C.