EN
6
1.
Place the compressor on a clean, flat surface or table top. Ensure there is nothing blocking the
AIR
VENTS
on either side of the compressor. Verify that the
ON/OFF SWITCH
is in the ‘Off’ position.
2.
Read and understand the instructions included with your reusable
AEROECLIPSE
* XL Breath
Actuated Nebulizer (BAN).
3.
Assemble the nebulizer as instructed.
4.
Connect one end of the
EZ Twist
TUBING
to the fitting on the bottom of the nebulizer and the
other end to the
AIR OUTLET
on the compressor. Ensure both ends are securely engaged. The
nebulizer may then be placed in the
CUP HOLDER
on the compressor until you are ready to start
your treatment as shown in Figure 4.
FIGURE 4
5.
Plug the
Ombra
* Table Top Compressor into an electrical outlet.
6.
In a relaxed, comfortably seated position, pick the nebulizer up out of the
CUP HOLDER
. Switch on
the compressor and start your treatment.
7.
When your treatment is complete or during a rest in your treatment, the nebulizer may be placed
back in the
CUP HOLDER
and the compressor switched off.
NOTE:
The compressor should be unplugged when not in use.
CLEANING AND MAINTENANCE
AIR FILTER
Your
Ombra
* Table Top Compressor is equipped with a special air filter that will slowly change colour
with use. The original filter is bright white, but it will slowly turn grey with use. Your air filter should be
changed every 30 days, or as visual inspection indicates. The compressor should never be used without
an air filter installed.
To change the filter (Figure 5)
1.
Remove
AIR FILTER COVER
by holding the cover and turning counterclockwise approximately 90
degrees. Pull the cap and filter cover out.
2.
Remove filter from the cover, and dispose of the old filter.
3.
Insert a new filter into the cover, then place the
AIR FILTER COVER
back into the compressor and
turn clockwise approximately 90 degrees to tighten.
4.
Do not over tighten. There will be resistance when the
AIR FILTER COVER
is securely fastened.