Quick set up guide for AirSim Standard, Multi and Bronchi  
 

1. 

Remove the AirSim unit from the black carrier case, with blue bag and  
plastic connector (if applicable). 

 

2.       Connect one end of the plastic connector to the open section of the left  
           Bronchi on AirSim airway (if applicable)  
 
3.       Connect the other end of the plastic connector to the blue lung bag (if  

applicable) 

 
4.    

Ensure that the tongue is inflated with approx 20ml of air.  This will  
create normal lingual tension.  Increasing the amount of air will create  
a more difficult airway management scenario.  

 
5. 

The neck can be adjusted and locked using the ‘Wing nut’ tensioner.   
Using this neck lock system, the head can be accurately placed in the   
‘sniffing  the  morning  air’  position.    This  is  achieved  when  the  head  is 
moved  so that  the  red  marks  on  the fixed  neck  joint  are  in  alignment.  
For more difficult airway management scenarios the head can be fixed 
in a more forward position.     

 
6.  

Using 

Trucorp’s silicone lubricant ensure that the internal airway is well  

lubricated including the tongue, hard palate, back of the mouth and  
epiglottis.  If appropriate ensure that the nasal passage is lubricated.   

 
7.  

Ensure that all airway devices are prepared to the manufactures  
recommendations and instructions.  Before insertion of the device  
generous amounts of lubricant should be used to cover the surfaces in  
contact with the AirSim airway.   

 
8. 

Please ensure that the AirSim airway is cleaned after use.  Please use 
warm water  of  a dilute (8-10% w/w) Sodium Bicarbonate solution until 
all visible foreign matter and residue is removed.   

 
9. 

Please  replace  the  AirSim  unit  back  into  the  carrier  case  and  store  in 
clean,  dry  conditions  away  from  heat  and  light;  avoid  contact  with 
metals, solvents, oils or greases and strong detergents. 

 
 

 

 
 
 

 
 
 
 

Содержание AirSim

Страница 1: ...AirSim User Manual Version 4 1 ...

Страница 2: ...ge 4 Quick set up guides AirSim Standard Multi Bronchi 15 AirSim Advance 16 AirSim Advance Bronchi 16 AirSim Advance Crico 18 AirSim Advance Traci 20 AirSim Advance Larynx 22 AirSim Baby 25 AirSim Pierre Robin 25 AirSim Child 26 Airway management 27 Care and maintenance 32 Warranty 33 ...

Страница 3: ...e the learning and development of airway management skills for all health professionals The innovated development and manufacture approach used makes the AirSim airway unique The main features of the AirSim Airway which makes it unique include The airway is moulded from a master which was created from data collected from a CT scan of a person The one piece mould together with the sophisticated dip...

Страница 4: ...f positions This ranges from the standard sniffing position to more difficult scenarios The AirSim Standard also features an inflatable tongue with real life size and texture There is also an option to include breakout teeth to simulate the effects of bad practice in laryngoscopy Contents Included in the black carry case are the following items 1 x AirSim Standard airway management manikin 1 x Blu...

Страница 5: ...ilar to the main airway This gives the same anatomical realism and functionality important landmarks such as the turbinates are clearly defined In addition the material used offers the same tactile feedback which is delivered with the main airway itself Contents Included in the black carry case are the following items 1 x AirSim Multi airway management manikin 1 x Blue Lung Bag with connector 1 x ...

Страница 6: ...hi provides exceptional detail in both internal and external features made possible through a combination of cutting edge moulding technology and carefully handcrafted processes Contents Included in the black carry case are the following items 1 x AirSim Bronchi airway management manikin 1 x Foam Block for securing the head in a neutral position during storage 1 x User manual CD ...

Страница 7: ...Multi unit however for added realism a head and neck skin has been added It is lightweight and portability and maintains the unique features such as the AirSim airway and nasal passage Contents Included in the black carry case are the following items 1 x AirSim Advance Airway Management Manikin 1 x Blue Lung Bag with connector 1 x User manual CD ...

Страница 8: ...tures an improved neck design allowing for accurate articulation and provides exceptional detail in both internal and external features Contents Included in the black carry case are the following items 1 x AirSim Advance Bronchi Airway Management Manikin 1 x User Manual CD Please note bag mask ventilation cannot be achieved on this model due to the closed cell Bronchi features Additional lung bags...

Страница 9: ...re It is anatomically correct with a replaceable neck skin and larynx It is lightweight and portable and maintains the unique features such as the AirSim airway and nasal passage together with the additional palpable thyroid cartilage cricothryoid membrane and cricoid cartilage Contents Included in the black carry case are the following items 1 x AirSim Advance Crico Airway Management Manikin 1 x ...

Страница 10: ...cheostomy procedure It is anatomically correct with a replaceable neck skin which can last up to 25 times and a representative larynx It is lightweight and portable and maintains the unique features such as the AirSim airway and nasal passage together with the additional palpable thyroid cartilage and cricoid cartilage Contents Included in the black carry case are the following items 1 x AirSim Ad...

Страница 11: ... in CO2 laser removal techniques These features combined with the real feel skin covering make the AirSim Advance Larynx the most comprehensive and cost effective training tool available for training and aspiring ENT surgeons Each model will come with 3 silicone and 3 TLT vocal cord inserts as standard The AirSim Advance larynx is presented on a light and sturdy base frame and is neatly packaged w...

Страница 12: ...Sim Baby facilities training in the use of bag mask ventilation supraglottic airway insertion and both naso and orotracheal intubation In addition is can be used with all current video laryngoscopes Presented in a lightweight but sturdy frame AirSim Baby comes shipped with its own lungs to demonstrate correct tube placement and is neatly packaged with its own lightweight case for easy transportati...

Страница 13: ...with mandibular hypoplasia Features significant mandibular hypoplasia glossoptosis cleft palate and a bifid uvula It is an anatomically correct model with very realistic features to allow for high fidelity training of difficult airway management True to Trucorp s well known branding the model is presented on a lightweight and sturdy frame The model comes shipped with its own lungs to demonstrate c...

Страница 14: ...intubation both nasal and oral Realistic and true internal anatomical features allow for an efficient and successful demonstration of all paediatric videolaryngoscopes True to Trucorp s products this model is presented in an aesthetically pleasing lightweight frame with lung bags included to illustrate correct tube placement This model also comes with a lightweight carrier case as standard for eas...

Страница 15: ... red marks on the fixed neck joint are in alignment For more difficult airway management scenarios the head can be fixed in a more forward position 6 Using Trucorp s silicone lubricant ensure that the internal airway is well lubricated including the tongue hard palate back of the mouth and epiglottis If appropriate ensure that the nasal passage is lubricated 7 Ensure that all airway devices are pr...

Страница 16: ...ed 6 Ensure that all airway devices are prepared to the manufactures recommendations and instructions Before insertion of the device generous amounts of lubricant should be used to cover the surfaces in contact with the AirSim airway 7 Please ensure that the AirSim airway is cleaned after use Please use warm water of a dilute 8 10 w w Sodium Bicarbonate solution until all visible foreign matter an...

Страница 17: ...m Advance Bronchi head from base The head can be detached from the base by removing the 3 bolts from the underside of the base as shown below 3 2 1 The head can be reattached to the base by attaching screws in positions 1 2 before attaching 3 ...

Страница 18: ...functioning product 6 After a nominal amount of procedures ensure that the airway sealing tape is replaced as this will affect the airtight quality of the product 7 The larynx can be removed easily and another piece of sealing tape cut to approx 5 6cm and attached over the Cric hole in the airway Please ensure that the airway is clean and dry before attaching the tape to ensure secure tape adhesio...

Страница 19: ...aterial 14 Please replace the AirSim Advance Crico unit back into the carrier case and store in clean dry conditions away from heat and light avoid contact with metals solvents oils or greases and strong detergents Trucorp provide the following spare parts for the AirSim Advance Crico These can be ordered while purchasing using the following codes LA1000 1 x Larynx Anatomical Larynx containing the...

Страница 20: ...fter a nominal amount of procedures ensure that the airway sealing tape is replaced as this will affect the airtight quality of the product 7 The larynx can be removed easily and another piece of sealing tape cut to approx 5 6cm and attached over the Traci hole in the airway Please ensure that the airway is clean and dry before attaching the tape to ensure secure tape adhesion 8 To ensure the lary...

Страница 21: ...AirSim Advance Traci unit back into the carrier case and store in clean dry conditions away from heat and light avoid contact with metals solvents oils or greases and strong detergents Trucorp provide the following spare parts for the AirSim Advance Traci These can be ordered while purchasing using the following codes TT1000 1 x Larynx Anatomical Larynx containing the Thyroid Cartilage and trachea...

Страница 22: ...tioned correctly so that it is facing away from the head so that the laser securing apparatus can be mounted Also please ensure the screw nut is secured and in place 7 When choosing on the appropriate vocal cord insert please ensure that if a laser is being used for laser techniques that only to use the TLT material serial codes LVC This material has been tested to not give out toxic fumes upon Co...

Страница 23: ...aterial is used for ablation 12 Using Trucorp s silicone lubricant ensure that the internal airway and Nasal passage is well lubricated if used for airway management If applicable 13 Ensure that all airway devices are prepared to the manufactures recommendations and instructions Before insertion of the device generous amounts of lubricant should be used to cover the surfaces in contact with the Ai...

Страница 24: ... cause very damaging effects to the model and destroy the outer silicone facial skin and the internal latex airway Also there is a high risk chance of fire damage to the models when exposing the laser to the areas mentioned above other than on the vocal cord inserts The vocal cord inserts should be the only area that is in direct contact with the laser Misuse or application of the laser at any oth...

Страница 25: ...er the surfaces in contact with the AirSim airway 5 Please ensure that the AirSim Baby and Pierre Robin airway is cleaned after use Please use warm water of a dilute 8 10 w w Sodium Bicarbonate solution until all visible foreign matter and residue is removed 6 The head and neck skin of the AirSim Baby and Pierre Robin is made from durable and very elastic polyurethane material It can be cleaned us...

Страница 26: ...over the surfaces in contact with the AirSim airway 5 Please ensure that the AirSim Child airway is cleaned after use Please use warm water of a dilute 8 10 w w Sodium Bicarbonate solution until all visible foreign matter and residue is removed 6 The head and neck skin of the AirSim Child is made from durable and very elastic polyurethane material It can be cleaned using a lightly soaped damp clot...

Страница 27: ...ddition of Naso tracheal intubation Awake fibreoptic examination Bag mask ventilation techniques TruCorp recommend the following equipment sizes for optimal performance 7 0 7 5 mm ID for nasal intubation 8 0 9 0 mm ID for oral intubation Size 3 and 4 for LMA laryngeal masks similar respective sizes for other supraglottic devices The AirSim Bronchi The AirSim Bronchi unit will provide a solution to...

Страница 28: ...ion techniques TruCorp recommend the following equipment sizes for optimal performance 7 0 7 5 mm ID for nasal intubation 8 0 9 0 mm ID for oral intubation Size 3 and 4 for LMA laryngeal masks similar respective sizes for other supraglottic devices The AirSim Advance Bronchi The AirSim Advance Bronchi can be used in a similar manner to the AirSim Advance and can cover an extensive range of trainin...

Страница 29: ...devices Laryngoscopes Tracheal Tubes Fibreoptic Laryngoscopes Naso tracheal intubation Awake Fibreoptic examination Bag mask ventilation techniques TruCorp recommend the following equipment sizes for optimal performance 7 0 7 5 mm ID for nasal intubation 8 0 9 0 mm ID for oral intubation Size 3 and 4 for LMA laryngeal masks similar respective sizes for other supraglottic devices The AirSim Advance...

Страница 30: ...icothryoidotomy Naso tracheal intubation Awake Fibreoptic examination Bag mask ventilation techniques TruCorp recommend the following equipment sizes for optimal performance 7 0 7 5 mm ID for nasal intubation 8 0 9 0 mm ID for oral intubation Size 3 and 4 for LMA laryngeal masks similar respective sizes for other supraglottic devices The AirSim Baby The AirSim Baby can be used in the training of a...

Страница 31: ...ques Endotracheal intubations TruCorp recommend the following equipment sizes for optimal performance Size 5 5 6 oro tracheal tubes size 4 5 5 0 naso tracheal tubes Size 2 for LMA laryngeal masks similar respective sizes for other supraglottic devices Size 2 for video laryngoscopes Needle Access The AirSim product range for the AirSim Standard Multi and Bronchi can be readily used for training in ...

Страница 32: ...ith the manufacturer s instructions and at the proper dilution The detergent must not contain skin or mucous membrane irritants Clean the device using a small soft bristle brush approximately inch or 12 5mm in diameter Gently insert the brush through the airway taking care not to damage the material Extra care must be taken when cleaning around the vocal cords Thoroughly rinse the airway in warm f...

Страница 33: ...th or shows evidence of having been damaged by excessive heat the use of sharp instruments misapplication misuse or other operating conditions outside of TruCorp s control Components which wear or are damaged by misuse are not warranted and will charged if repair has been approved Before returning any models please contact TruCorp To avoid delays please ensure the following information is availabl...

Отзывы: