List of procedures facilitated by the AirSim Pierre Robin X  

 

Double naso-tracheal intubation 

 

Bag valve mask (BVM) ventilation techniques 

 

Full range of supraglottic devices 

 

Direct and video laryngoscopy 

 

Endotracheal tube insertion 

 

Care and maintenance 

Store in clean, dry conditions away from heat and direct sunlight; avoid contact with metals, 
solvents, oils or greases and strong detergents. When the product is not in use please store 
in the black carrier case provided.  

Thoroughly  wash  the  AirSim  X  airway  in  warm  water.  Please  use  warm  soapy  water  or 
something similar until all visible foreign matter and residue is removed. 

Mild detergents or enzymatic cleaning agents may be used on the airway in accordance with 
the manufacturer's instructions and at the proper dilution. The detergent must not contain 
skin or mucous membrane irritants. 

Please do not use any of the following when cleaning the AirSim product range 

 

Germicides, disinfectants, or chemical agents such as glutaraldehyde (e.g. Cidex®), 

 

Ethylene oxide, phenol-based cleaners or iodine-containing cleaners 

In  response  to  the  recent  COVID-19  pandemic,  we  recommend  this  additional  step  to 
ensure the product is fully sanitised: 

 

Use alcohol spray (minimum 75%) and wipe off. Repeat this for 3-4 times to ensure to kill 
the virus completely. This method can be used on both the silicone skin and the latex 
airway. 

Warranty

 

TruCorp warrants this unit to be free of defects in materials and workmanship and to give 
satisfactory service for a period of 1-year from the date of delivery. This ensures that our 
customers receive maximum coverage on each product. If the unit should malfunction it  

Содержание AirSim Pierre Robin X

Страница 1: ... in collaboration with clinicians from Children s Hospital of Los Angeles This realistic training manikin highlights difficult airway management techniques for infants with Pierre Robin Sequence Syndrome PRS The nasal cavity and airway include important internal landmarks for training in endo tracheal and nasotracheal intubations TruCorp are proud to offer a 5 year warranty on the AirSim X airway ...

Страница 2: ...ntents Product specifications 3 Package contents 3 Recommended equipment sizes 3 Initial set up information 3 List of procedures facilitated by the AirSim Pierre Robin X 4 Care and maintenance 4 Warranty 4 ...

Страница 3: ... devices Size 1 for video laryngoscopy Initial set up information Gently remove the model from the carrier case Secure the manikin to a suitable surface by adjusting the screw on the suction cups surface must be non porous to ensure sufficient suction The head can be placed in a neutral or sniffing position by rotating the head if required for direct laryngoscopy Please ensure two lung bags and on...

Страница 4: ...e manufacturer s instructions and at the proper dilution The detergent must not contain skin or mucous membrane irritants Please do not use any of the following when cleaning the AirSim product range Germicides disinfectants or chemical agents such as glutaraldehyde e g Cidex Ethylene oxide phenol based cleaners or iodine containing cleaners In response to the recent COVID 19 pandemic we recommend...

Страница 5: ...reight delivery of the TruCorp airway free of charge if the airway fails within the 5 year period However these warranties are VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged by excessive heat the use of sharp instruments misapplication misuse or other operating conditions outside of TruCorp s control Components which wear or are damaged by mis...

Отзывы: