background image

2

 

 

 

TRU

WELD

 

EQUIPMENT

 

LIMITED

 

WARRANTY

 

All

 

goods

 

produced

 

by

 

Tru

Weld

 

Equipment

 

shall

 

be

 

warranted

 

against

 

defects

 

including

 

workmanship

 

and

 

components.

 

No

 

other

 

war

ranties

 

whether

 

expressed,

 

verbal,

 

or

 

implied

 

will

 

apply.

 

Warranties

 

only

 

apply

 

to

 

the

 

original

 

equipment

 

purchaser.

   

Warranty

 

claims

 

will

 

be

 

limited

 

to

 

either

 

repair

 

or

 

replacement

 

of

 

the

 

defective

 

materials

 

by

 

Tru

Weld

 

Equipment.

 

At

 

the

 

option

 

of

 

Tru

Weld

 

Equipment

 

the

 

location

 

of

 

where

 

the

 

warranty

 

evaluation

 

and

 

repairs

 

are

 

made

 

will

 

be

 

determined.

 

All

 

warranty

 

claim

 

items

 

re

turned

 

to

 

Tru

Weld

 

Equipment

 

will

 

be

 

at

 

the

 

customer’s

 

expense.

 

At

 

the

 

option

 

of

 

Tru

Weld

 

Equipment

 

the

 

defect

 

will

 

either

 

be

 

re

paired

 

or

 

replaced.

 

Notice

 

must

 

be

 

provided

 

to

 

Tru

Weld

 

Equipment

 

of

 

a

 

warranty

 

defect

 

within

 

30

 

days

 

that

 

the

 

defect

 

or

 

failure

 

is

 

incurred.

 

Warranties

 

are

 

not

 

transferable.

  

This

 

warranty

 

does

 

not

 

apply

 

for

 

equipment

 

which

 

is

 

used

 

improperly

 

in

 

any

 

fashion

 

including

 

but

 

not

 

exclusive

 

to

 

the

 

following:

 

Equipment

 

which

 

has

 

been

 

modified

 

Equipment

 

which

 

has

 

not

 

been

 

installed

 

properly

 

Equipment

 

which

 

has

 

been

 

used

 

for

 

purposes

 

other

 

than

 

which

 

it

 

had

 

been

 

designed

 

Equipment

 

which

 

has

 

not

 

been

 

properly

 

maintained

 

Equipment

 

which

 

was

 

continued

 

to

 

be

 

used

 

after

 

a

 

defect

 

had

 

been

 

found

 

Equipment

 

which

 

was

 

damaged

 

in

 

any

 

way

 

Tru

Weld

 

Equipment

 

will

 

never

 

be

 

liable

 

for

 

consequential

 

damages,

 

loss,

 

or

 

expense

 

occurring

 

directly

 

or

 

indirectly

 

from

 

the

 

use

 

of

 

the

 

equipment

 

covered

 

in

 

this

 

warranty.

 

All

 

cables,

 

cable

 

sets

 

and

 

connectors

 

are

 

not

 

warranted.

 

 

Two

 

(2)

 

year

 

warranty

 

period

 

from

 

date

 

of

 

purchase

 

 

 

SC900

 

Power

 

Supply

 

SC3400

 

Power

 

Supply

 

 

 

SC2420

 

Power

 

Supply

 

SC2402

 

Power

 

Supply

 

 

 

SC2400

 

Power

 

Supply

 

SC900

 

Power

 

Supply

 

 

 

SC1900

 

Power

 

Supply

 

SC1950

 

Power

 

Supply

 

 

 

SC1600

 

Power

 

Supply

 

SC1650

 

Power

 

Supply

 

 

 

SC1400

 

Power

 

Supply

 

SC1450

 

Power

 

Supply

 

 

 

TWE250

 

Power

 

Supply

 

TWE321

 

Power

 

Supply

 

 

 

TWE375

 

Power

 

Supply

 

 

One

 

(1)

 

year

 

warranty

 

period

 

from

 

date

 

of

 

purchase

 

 

 

TWESPC

 

Power

 

Supplies

 

 

 

TWP

2

     

Power

 

Supply

 

 

Ninety

 

Day

 

warranty

 

period

 

from

 

date

 

of

 

purchase

  

 

        

(Excluding

 

cables

 

and

 

connectors)

 

 

 

TWE70000

 

HD

 

Arc

 

stud

 

gun

 

 

 

TWE18500

 

MD

 

Arc

 

stud

 

gun

 

 

 

TWE19000

 

LD

 

Arc

 

stud

 

gun

 

 

 

TWEG

 

CD

 

stud

 

gun

 

 

 

TWEHDG

 

Heavy

 

Duty

 

CD

 

stud

 

gun

 

Содержание ARWSC900

Страница 1: ...y integrated stud welding system for ferrule shielded and gas shielded drawn arc stud welding The SC900 con tains digital controls for weld time weld current and gas purge time The system was designed...

Страница 2: ...which has been modified Equipment which has not been installed properly Equipment which has been used for purposes other than which it had been designed Equipment which has not been properly maintain...

Страница 3: ...cess and growth If we can be of any further assistance to you and your company please do not hesitate to contact us Product Information The SC900 is a fully integrated stud welding system for ferrule...

Страница 4: ...esigned and built with operator safety in mind but safety begins with you Every effort has been made to protect the trained operator from injury Please become familiar with the information in this man...

Страница 5: ...ne before moving a welding power source Always be sure the work cable makes a good electrical connection with the metal being welded The connection should be as close as possible to the area being wel...

Страница 6: ...the area being welded Keep welding power source and cables as far away from your body as possible Electromagnetic fields can irrevocable erase magnetic data carriers computer memory credit cards secu...

Страница 7: ...welding interlock keeps system from double triggering SC900 Product Specifications Specifications are subject to change without prior notification Weld Range 14ga to 1 2 Consistent welding regardless...

Страница 8: ...ng materials that may obstruct airflow through the welder If the equipment is not being installed immediately store it in a clean dry well ventilated area until in stallation Selecting a Location The...

Страница 9: ...made are accessi ble with the top cover removed Primary Power Cable Route the Primary Power Cable through the Power Inlet Hole in the center connector on the back side of the welder Connect the power...

Страница 10: ...line voltages depending on your requirements Simply plug in the appropriate voltage con nector for either 230VAC red wired connector or 460VAC black wired connector 3 Phase opera tion Ground Cable Co...

Страница 11: ...front of the welder Connect stud gun cable assembly directly to the SC900 Plug stud gun control cable plug into the connector on the front of welder Gas line connection When gas shield welding connect...

Страница 12: ...stud to be welded After all of the proper accessories have been mounted on the stud gun place the stud in the chuck and begin the alignment of the accessories Make certain that a sufficient amount of...

Страница 13: ...nging in diameter through 3 4 this adjustment should be suitable For larger diameter studs and select applications the lift should be adjusted to approximately 1 8 Adjusting the lift Remove the back c...

Страница 14: ...an be used to control the force with which the stud is plunged into the molten weld pool by moving the engagement point of when the shaft of the stud gun engages the damp ener Rotating the dampener co...

Страница 15: ...complete the circuit and actuate the stud gun Make sure welder is set up properly to begin the welding process Place the selected stud into the chuck and attach the ferrule to the ferrule grip Place s...

Страница 16: ...e 3 times indicating that there is a good connection SC900 Diagnostic Lights On the Control Panel located below the digital display is a row of diagnostic lights for the welder OUTPUT When the stud gu...

Страница 17: ...chosen during setup When setting time or current depress and hold down appropriate button and turn Adjustment Dial clockwise or counter clockwise to the correct setting on the digital display Use the...

Страница 18: ...was drawn or not Job Counter Resettable This is a running total of the number of welds since the counter was last reset To view the job counter set the Fine Coarse Switch to the Fine position Each wel...

Страница 19: ...gs from being adjusted The purpose is to allow a meas ure of process control All settings and the counter may be viewed when the lock is activated To activate the lock turn clockwise toward the 3 o cl...

Страница 20: ...weld The main spring plunges the weld stud down into the molten pool of metal in the base material The cycle is completed in less than a second and the resulting weld bond develops the full strength o...

Страница 21: ...ud pro trudes beyond the ferrule Make sure work surface is relatively clean so impurities do not affect weld Test the welds at the beginning of each shift or change in stud Check burn off 1 8 color si...

Страница 22: ...a bumpy or jagged collar around the base of the weld stud This normally occurs when the weld time is set too high Porous Weld Collar This usually occurs from the oxidation of the weld pool resulting...

Страница 23: ...o lift from gun coil trigger is good Bad connection or faulty equipment 1 Test control cable by plugging weld tool directly into unit 4 conductor straight through wiring 2 Check 5 amp fuse next to bre...

Страница 24: ...and connections in cluding grounds 3 Test the power loop by making welds on a test piece us ing only the starter cable set 4 Test 3 phase power to control contactor 5 Check taps if applicable on main...

Страница 25: ...25 TRU WELD Equipment Company 6400 N Honeytown Road Smithville Ohio 44677 330 725 7744 Phone 330 669 2473 Fax TWE tfpcorp com http truweldstudwelding com...