background image

 

 

4

Battery test setting 

When the Power Output switch is set to Full Power with Battery Test, the indicator lights show the charge level of the battery and other 
battery information. The battery test is only relevant when a lead-acid battery is used. The table below explains what the indicator lights 
represent and any action required for each installation. 

Lights 

Battery-only installation 

Solar installation 

Green light on 

Optimal battery charge level: 

• 

• 
• 

• 
• 

• 

No action required. 

Optimal battery charge level. (Readings for a solar 
installation are only accurate in the early morning or late 

evening when the solar panel has been out of  the 
sunlight for several hours.) 

Yellow light on 

Medium battery charge level: 

Monitor battery charge level. 
Recharge the battery to avoid long term 
battery damage. 

Low to Medium battery charge level: 

Recharge the battery immediately. 
Check the solar panel wiring is connected properly 
and is intact. 
Check that the solar panel is installed correctly and 
is clean. 

If the problem recurs, the panel may be inadequate or 
faulty. 
Take the entire system to an authorised service agent for 
assessment. 

Red light on 

Low battery charge level: 

• 

• 

Recharge the battery immediately. 

Low battery charge level: 

See Low to Medium battery charge level above 

Green light flashing 

Not applicable. 

Battery connections may be faulty: 

• 

• 
• 

• 

Check that the battery clips are connected properly 
and that the wiring is intact. 

Battery may be over-charged or faulty: 

Disconnect the solar panel for 24 hours 
Reconnect the solar panel and monitor for seven 
days. 

If the light flashes within seven days,  there may be 
something wrong with the system. 

Take the entire system to an authorised service 
agent for assessment. 

Red light flashing 

Battery may be faulty: 

• 

• 

• 

• 

Recharge the battery and monitor battery 
performance for seven days. 
If the light flashes within seven days, the 

battery should be checked by a battery 
specialist and replaced if necessary. 

Battery may be faulty: 

Recharge the battery and monitor battery 
performance for seven days. 
If the light flashes within seven days, the battery 

should be checked by a battery specialist and 
replaced if necessary. 

 
 

Содержание speedrite Delta 1B

Страница 1: ...TM speedrite by WARNING READ ALL INSTRUCTIONS Delta Battery Energizer USER MANUAL ELECTRIC FENCING FOR THE SERIOUS FARMER...

Страница 2: ...s of Tru Test Corporation Limited No part of this publication may be photocopied reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying r...

Страница 3: ...se lightning striking your fence will be conducted to all other devices Symbols that may be on your energizer To reduce the risk of electric shock the energizer should be opened or repaired only by qu...

Страница 4: ...nal of the battery and the black clip to its negative terminal Interior installations For interior installations make sure the energizer and battery are level Mount them above floor level and out of r...

Страница 5: ...all times Auto The energizer will adjust its pulse speed to conserve battery power depending on the battery charge level See the table below Fast nocturnal The energizer will pulse fast at night and s...

Страница 6: ...ctly and is clean If the problem recurs the panel may be inadequate or faulty Take the entire system to an authorised service agent for assessment Red light on Low battery charge level Recharge the ba...

Страница 7: ...r Fast Pulse Half Power Fast Pulse 70 mA 35 mA 70 Ah 35 Ah Delta 2B Full Power Fast Pulse Half Power Fast Pulse 140 mA 70 mA 140 Ah 70 Ah Delta 3B Full Power Fast Pulse Half Power Fast Pulse 340 mA 17...

Страница 8: ...to the weather When not in use keep the battery as fully charged as possible Recharge a discharged battery as soon as possible Batteries should be stored fully charged and recharged at regular interv...

Страница 9: ...peedrite distributor which design best suits your needs Some suggested fence configurations are below Cattle and horses 10 15 m 33 49 spacing posts only 15 20 m 49 65 spacing with droppers Sheep goats...

Страница 10: ...imum number of 2 m 6 6 earth rods recommended for an earthing system Energizer Earth rods Delta 1B 0 5 J 1 Delta 2B 1 0 J 2 Delta 3B 2 5 J 3 Test the earth system using the following procedure 1 Turn...

Страница 11: ...ally isolated from the electric fence Physical barrier A barrier not less than 1 5 m 5 high intended to prevent inadvertent contact with the pulsed conductors of the electric fence Physical barriers a...

Страница 12: ...lectric animal fence wires are installed near an overhead power line their height above the ground shall not exceed 3 m 10 This height applies to either side of the orthogonal projection of the outerm...

Страница 13: ...ood condition and the voltage is still below 4 kV talk to your Speedrite distributor They will help you identify whether recent extensions to your fence a poor fence layout or soil conditions may be c...

Страница 14: ...panel Current Consumption Fast Full Power Fast Half Power 70 mA 35 mA 140 mA 70 mA 340 mA 170 mA Maximum Output Voltage 7 9 kV 8 4 kV 8 4 kV Maximum Output Energy 0 5 J at 700 1 0 J at 400 2 5 J at 20...

Страница 15: ......

Страница 16: ...TM speedrite by SAVE THESE INSTRUCTIONS www speedrite com...

Отзывы: