TM
speedrite
®
by
WARNING: READ ALL INSTRUCTIONS
Delta Battery Energizer
U S E R M A N U A L
ELECTRIC FENCING FOR THE SERIOUS FARMER
Страница 1: ...TM speedrite by WARNING READ ALL INSTRUCTIONS Delta Battery Energizer USER MANUAL ELECTRIC FENCING FOR THE SERIOUS FARMER...
Страница 2: ...s of Tru Test Corporation Limited No part of this publication may be photocopied reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying r...
Страница 3: ...se lightning striking your fence will be conducted to all other devices Symbols that may be on your energizer To reduce the risk of electric shock the energizer should be opened or repaired only by qu...
Страница 4: ...nal of the battery and the black clip to its negative terminal Interior installations For interior installations make sure the energizer and battery are level Mount them above floor level and out of r...
Страница 5: ...all times Auto The energizer will adjust its pulse speed to conserve battery power depending on the battery charge level See the table below Fast nocturnal The energizer will pulse fast at night and s...
Страница 6: ...ctly and is clean If the problem recurs the panel may be inadequate or faulty Take the entire system to an authorised service agent for assessment Red light on Low battery charge level Recharge the ba...
Страница 7: ...r Fast Pulse Half Power Fast Pulse 70 mA 35 mA 70 Ah 35 Ah Delta 2B Full Power Fast Pulse Half Power Fast Pulse 140 mA 70 mA 140 Ah 70 Ah Delta 3B Full Power Fast Pulse Half Power Fast Pulse 340 mA 17...
Страница 8: ...to the weather When not in use keep the battery as fully charged as possible Recharge a discharged battery as soon as possible Batteries should be stored fully charged and recharged at regular interv...
Страница 9: ...peedrite distributor which design best suits your needs Some suggested fence configurations are below Cattle and horses 10 15 m 33 49 spacing posts only 15 20 m 49 65 spacing with droppers Sheep goats...
Страница 10: ...imum number of 2 m 6 6 earth rods recommended for an earthing system Energizer Earth rods Delta 1B 0 5 J 1 Delta 2B 1 0 J 2 Delta 3B 2 5 J 3 Test the earth system using the following procedure 1 Turn...
Страница 11: ...ally isolated from the electric fence Physical barrier A barrier not less than 1 5 m 5 high intended to prevent inadvertent contact with the pulsed conductors of the electric fence Physical barriers a...
Страница 12: ...lectric animal fence wires are installed near an overhead power line their height above the ground shall not exceed 3 m 10 This height applies to either side of the orthogonal projection of the outerm...
Страница 13: ...ood condition and the voltage is still below 4 kV talk to your Speedrite distributor They will help you identify whether recent extensions to your fence a poor fence layout or soil conditions may be c...
Страница 14: ...panel Current Consumption Fast Full Power Fast Half Power 70 mA 35 mA 140 mA 70 mA 340 mA 170 mA Maximum Output Voltage 7 9 kV 8 4 kV 8 4 kV Maximum Output Energy 0 5 J at 700 1 0 J at 400 2 5 J at 20...
Страница 15: ......
Страница 16: ...TM speedrite by SAVE THESE INSTRUCTIONS www speedrite com...