background image

 

3–12 

OUTPUT DEVICE 

The compactor can send the data to a computer or serial printer via 
the serial (RS-232) port, or to a USB printer or memory device 
(thumb drive) via the USB port. To select the destination for the 
output data, press 

3

 from the 

Data Output

 menu shown on page 

3–10. The compactor displays: 
 

-Output Destination- 

1- Serial Port 
2- USB Printer 
3- Thumb Drive 

 
Press the numeric key that corresponds to the desired output 
destination. The compactor displays a brief confirmation message 
and returns to the 

Output Destination

 menu. Press 

ESC

 to 

return to the 

Data Output

 menu. 

 
The GyroImport software

 

is used to convert the data on the USB 

memory device to a Microsoft Excel workbook. The software may 
be downloaded from the 5850v2 product page on the Troxler 
website (www.troxlerlabs.com) or it can be requested from 
Customer Service at 

1-877-TROXLER

.  

 
 

OUTPUT FORMAT 

The Model 5850v2 outputs data in a 

height-versus-gyration

 format, 

similar to the one shown in Figure 3–1, and shows the specimen 
height, or thickness, for each gyration during a compaction cycle. A 

full table 

output includes specimen height, gyration angle, ram 

pressure, and shear stress (if enabled) for each gyration. 
 
To print the output data, press 

4

 from the 

Data Output

 menu 

(shown on page 3–10). The compactor displays: 
 

-Output Format- 

1- Table 
2- Formatted 
3- GyroPave 

Содержание 5850v2

Страница 1: ...ly important to understand the Safety Warnings on page 1 1 Keep this manual in a safe place that is always easily accessible during the use of the Model 5850v2 Troxler Electronic Laboratories Inc 3008...

Страница 2: ...ans electronic or mechanical including photocopying recording or information storage and retrieval systems for any purpose without the express written permission of Troxler Electronic Laboratories Inc...

Страница 3: ...1430 Brook Drive Downers Grove IL 60515 Phone 1 630 261 9304 Fax 1 630 261 9341 TroxTechSupport troxlerlabs com WESTERN BRANCH OFFICE SERVICE CENTER 11300 Sanders Drive Suite 7 Rancho Cordova CA 9574...

Страница 4: ...es the compactor keypad and provides instructions for setting up starting and operating the compactor Chapter 3 Setup Menu Provides a detailed description of the options available from the compactor s...

Страница 5: ...troubleshooting and general maintenance Do not attempt to operate the Model 5850v2 before reading this manual and the safety warnings posted on the unit Troxler stresses that the user is solely respo...

Страница 6: ...o ensure proper operation KEY Angle brackets and a different typestyle indicate a key or character number or letter to press on the compactor keypad For example Press START means to press the key labe...

Страница 7: ...cting a Specimen 2 6 Cleaning and Lubricating 2 8 Preparing a Specimen 2 10 Compacting the Specimen 2 14 Removing the Sample from the Mold 2 15 Cooling the Sample 2 16 Shear Options Performance Tests...

Страница 8: ...4 Replacing the Batteries A 7 Cleaning the Cooling Fan A 8 Replacement Parts A 8 Returning Parts for Service A 9 APPENDIX B B 1 Menu Map Description B 2 APPENDIX C C 1 Environmental Conditions C 2 Ele...

Страница 9: ...ill Tube 1 13 Figure 2 1 Model 5850v2 Control Panel Layout 2 3 Figure 2 2 Compaction Chamber 2 9 Figure 2 3 Loading the Mold 2 12 Figure 3 1 Sample Height Versus Gyration Table 3 13 Figure 4 1 Alignin...

Страница 10: ...x LIST OF TABLES Table Title Page Table 2 1 Control Panel Keys and Button 2 2...

Страница 11: ...le of improper or unauthorized use of this unit that may lead to malfunction or accident Thus if a particular use is not specifically mentioned in this manual as authorized then consult Troxler about...

Страница 12: ...y when operating the compactor Keep hands away from the gyratory compactor when the unit is in motion With the service panels removed the gyratory compactor poses an electrical hazard Unplug the gyrat...

Страница 13: ...ts Lower Left Side of Compactor Connection for 100 240 VAC 50 60 Hz power to the compactor Upper Left Side of Compactor 9 pin RS 232C serial interface for connecting the compactor to a computer or ser...

Страница 14: ...obtaining meaningful test results Building upon the successes of Troxler s Model 4140 and 4141 Gyratory Compactors the Model 5850v2 has been completely redesigned with improved electronics a robust c...

Страница 15: ...e reading this manual and the safety warnings posted on the unit Troxler stresses that the operator is solely responsible for ensuring the safe use of the Model 5850v2 The manufacturer its subsidiarie...

Страница 16: ...ciety of Testing and Materials ASTM SI10 Standard for Use of the International System of Units SI The Modern Metric System CARE AND MAINTENANCE The Model 5850v2 requires little maintenance To reduce t...

Страница 17: ...Model 5850v2 1 7 1 INTRODUCTION Figure 1 1 Model 5850v2 Gyratory Compactor...

Страница 18: ...s the compactor to the printer or other USB device Part number 110697 The serial cable not shown connects the compactor to a serial device such as a computer Part number 106514 The extruder is used to...

Страница 19: ...see that the following are included Model 5850v2 Gyratory Compactor Mold Power cord Height standard assembly Specimen papers 500 per package Printer USB cable Serial cable Manual of Operation and Ins...

Страница 20: ...nit cut each side of the carton approximately 2 inches above the pallet Lift the carton up and off the unit 2 2 Remove the metal strap and bolts that secure the compactor to the pallet 3 3 Remove the...

Страница 21: ...ite Place the compactor on a flat level location Locate the compactor no more than 1 2 m 4 ft from the required electrical power source see Appendix C Ensure that the distance does not place stress on...

Страница 22: ...ISO VG 32 SAE 10 Troxler part number 018203 hydraulic oil to fill the hydraulic reservoir 2 2 Ensure that the oil level is at the 30 degree mark on the sight glass as shown in Figure 1 3 If oil is ne...

Страница 23: ...Model 5850v2 1 13 1 INTRODUCTION Figure 1 3 Proper Reservoir Fill Level Figure 1 4 Place a Funnel in Reservoir Fill Tube ENSURE FLUID LEVEL IS AT 30 DEGREE MARK FUNNEL...

Страница 24: ...code requirements Refer to the Electrical Specifications section on page C 3 for the current and voltage ratings for the compactor 7 7 If using the compactor with a USB printer or memory device conne...

Страница 25: ...OPERATION This chapter describes how to get started using the Model 5850v2 Gyratory Compactor This information includes a brief description of the control panel and instructions for turning the compac...

Страница 26: ...setting or viewing the run options setting the data output options calibrating the compactor verifying the calibration and clearing project data ESC Returns to the next higher level menu without upda...

Страница 27: ...Model 5850v2 2 3 2 SETUP OPERATION Figure 2 1 Model 5850v2 Control Panel Layout...

Страница 28: ...number of gyrations this value is 999 if the compactor is set to compact to a target specimen height AI Operator selected internal angle of gyration P Operator selected compaction pressure FIRST TIME...

Страница 29: ...gs selection The compactor displays Selected run count number of gyrations Selected mode number of gyrations or specimen height Specimen height Gyration angle Ram pressure Mold diameter Gyrate Delay R...

Страница 30: ...ibed on page 3 11 NOTE Before outputting data to a printer or computer ensure that the Model 5850v2 is properly connected to the output device COMPACTING A SPECIMEN WARNING To prevent personal injury...

Страница 31: ...e mold 5 5 Place the mold in the compactor chamber and compact the specimen 6 6 Remove the mold containing the compacted specimen from the compactor chamber and extrude the asphalt specimen using the...

Страница 32: ...head and the upper puck plate with Magnalube G 4 4 Clean the mold and pucks with Bindoff or similar cleaner CAUTION Do not use a degreasing cleaner or glass cleaner to clean the clear chamber door To...

Страница 33: ...Model 5850v2 2 9 2 SETUP OPERATION LOWER CARRIAGE PLATE RAM HEAD MOLD TRAY VIEW A UPPER PUCK PLATE UPPER CARRIAGE ASSEMBLY VIEW B Figure 2 2 Compaction Chamber...

Страница 34: ...CAUTION Do not heat the mold above 175 C 350 F Heating above this temperature may warp the mold and create errors in the angle of gyration NOTE Do not place the asphalt mixture into the mold while hea...

Страница 35: ...Model 5850v2 2 11 2 SETUP OPERATION part numbers 106952 or 106953...

Страница 36: ...while inserting it to prevent it from becoming wedged in the mold CAUTION If the upper or lower puck becomes wedged in the mold it must be removed and inserted correctly before compacting the asphalt...

Страница 37: ...Model 5850v2 2 13 2 SETUP OPERATION the chamber door...

Страница 38: ...amber door Press START If there is no mold in the chamber or if the mold is not in the proper location the compactor displays an error message If the mold is in place the compactor begins the compacti...

Страница 39: ...ght data The compactor then returns to the Machine Idle display shown on page 2 4 Open the chamber door and wearing heat resistant gloves remove the mold from the compaction chamber Extrude the specim...

Страница 40: ...that measure the shear forces acting on the specimen during gyration The Model 5850v2 also utilizes the Gyratory Shear Kit GSK which turns any gyratory compactor into a shear enabled unit without the...

Страница 41: ...1 3 SETUP MENU CHAPTER 3 SETUP MENU The compactor s Setup menu enables the operator to select and define the operating parameters of the Model 5850v2 Gyratory Compactor This chapter describes the man...

Страница 42: ...compaction data to calibrate the compactor and to perform other special functions To access the Setup menu press SETUP on the keypad Use the arrow keys to scroll through the menu options To select an...

Страница 43: ...s select View Settings from the Setup menu shown on page 3 2 The compactor displays Selected run count number of gyrations Selected mode number of gyrations or specimen height Specimen height Gyration...

Страница 44: ...yration angle 0 00 to 3 0 degrees Define the desired ram pressure 200 to 1000 kPa Select the mold diameter 150 mm 100 mm or 4 inch To access these options press 2 from the Setup menu see page 3 2 The...

Страница 45: ...ration Mode menu shown below Operation Mode 1 Gyrations 2 Specimen Height Press to Select Press the numeric key that corresponds to the desired operation mode The compactor displays a brief confirmati...

Страница 46: ...isplays Input Target Specimen Height mm 115 0 Press ENTER Use the number keys to enter the specimen height 50 to 200 mm Use the NO CE key to backspace Press ENTER The display returns to the Change Set...

Страница 47: ...pressure from 200 to 1000 kPa Use the NO CE key to backspace Press ENTER The display returns to the Change Settings menu MOLD DIAMETER CAUTION Ensure that the mold diameter selected in the compactor...

Страница 48: ...n on page 3 4 POST GYRATE DELAY The Model 5850v2 provides the option for a five minute delay upon completing the compaction of a specimen This delay maintains a minimum pressure on the sample and allo...

Страница 49: ...en the post gyrate delay is enabled after gyrations are complete the screen will display NOTE Where MM represents minutes and SS represents seconds During the delay the pump remains on The carriage pl...

Страница 50: ...roduct page on the Troxler website www troxlerlabs com The output data can be presented in either a height versus gyration or full table format These options are described on page 3 12 NOTE Before out...

Страница 51: ...he Data Output menu shown on page 3 10 The compactor searches the data records and then displays the specimens currently stored in memory as shown below 04 08 09 04 24P 04 08 09 01 52P 04 08 09 08 45A...

Страница 52: ...ta Output menu The GyroImport software is used to convert the data on the USB memory device to a Microsoft Excel workbook The software may be downloaded from the 5850v2 product page on the Troxler web...

Страница 53: ...nd then returns to the Data Output menu Press 3 to select GyroPave software compatible data format The data is similar to the Table format but only height measurements are output The compactor display...

Страница 54: ...n press 4 from the Setup menu see page 3 2 The compactor drives the four actuators to their home position while displaying Moving Gyratory to Home Position When the actuators are in their home positio...

Страница 55: ...llows for simple calibration of the specimen height and compaction pressure and for offsetting the angle of gyration This chapter provides a recommended schedule for calibration and verification of th...

Страница 56: ...er changing the ram pressure see page 3 7 PRESSURE CALIBRATION See page 4 6 for details on pressure calibration Calibrate the compaction pressure every 3 months SPECIMEN HEIGHT CALIBRATION See page 4...

Страница 57: ...able from Troxler part number 108706 To verify the internal angle follow the instructions in Chapter 3 to 1 1 Set the operation mode to number of gyrations 2 2 Set the number of gyrations to 20 3 3 Se...

Страница 58: ...ition 2 8 8 Follow the instructions provided with the internal angle device to measure the top angle Ensure that the probes of the internal angle device are aligned along Position 1 with the edge of t...

Страница 59: ...tion of the compaction pressure and specimen height and for offsetting the gyration angle To access the Calibration menu press 5 from the Setup menu shown on page 3 2 The compactor displays Calibratio...

Страница 60: ...or asphalt clean the mold tray ram head lower carriage plate upper carriage assembly and upper puck plate see Figure 2 2 on page 2 9 with Bindoff or similar cleaner 2 2 Connect the load cell as follo...

Страница 61: ...bration load cell in the center of the puck as shown below 3 3 Place the upper puck larger edge down centered on top of the load cell 4 4 Route the load cell cables through the notch in the upper cent...

Страница 62: ...4 8 Figure 4 3 Routing Load Cell Cables ROUTE CABLES THROUGH NOTCH LOAD CELL...

Страница 63: ...nection Press ENTER to continue Pressure Cal Verify Communication Error Check Load Cell Press ENTER 6 6 After measuring the unloaded pressure on the load cell the compactor raises the ram until the lo...

Страница 64: ...9 Open the chamber door and remove the calibration load cell and pucks Unplug the dc charger from the electrical outlet and disconnect the load cell from the dc charger and control unit Return all pa...

Страница 65: ...3 3 Close the chamber door and press ENTER The compactor displays Height Calibration Enter Std Height Press ENTER The height of the height standard assembly is stamped on its side Enter the height to...

Страница 66: ...commends verifying the angle after every 800 samples or once per year using an internal angle device such as the Dynamic Angle Verification DAV device available from Troxler Refer to page 4 3 for inst...

Страница 67: ...e is the value just entered Angle Offset Degrees 1 Change 2 Enable To enable the Angle Offset function using this value press 2 PRINT CALIBRATION The Print Calibration function can be used to manually...

Страница 68: ...4 14 NOTES...

Страница 69: ...APTER 5 SPECIAL FUNCTIONS The Model 5850v2 Gyratory Compactor firmware includes a number of functions that typically are not used on a day to day basis These functions are accessed from the Special me...

Страница 70: ...ll project specimen data and to reset the software To access these functions press 6 from the Setup menu The compactor displays the Special menu shown below Special 1 Clock Calendar 2 Erase Records 3...

Страница 71: ...shown below Use the arrow keys to scroll through the menu options To select an option press the numeric key that corresponds to desired option The following sections describe each selection Clock Cale...

Страница 72: ...ar menu shown on page 5 3 The compactor displays 04 08 2009 mm dd yyyy Input Date and Press ENTER Note that in this example the date is displayed in mm dd yyyy format To change the format see the Date...

Страница 73: ...that corresponds to the desired time format The compactor returns to the Clock Calendar menu DATE FORMAT The compactor can display the date in either mm dd yyyy or dd mm yyyy format where mm month dd...

Страница 74: ...the Special menu shown on page 5 2 The compactor displays Permanently Erase all Data Records YES or NO To erase all data records press YES The compactor restores the default settings displays a brief...

Страница 75: ...tants stored in the compactor memory To use this function press 3 from the Special menu shown on page 5 2 The compactor displays System Reset Sets System Variables to Defaults Continue YES or NO To re...

Страница 76: ...5 8 NOTES...

Страница 77: ...Model 5850v2 Appendix A 1 A TROUBLESHOOTING APPENDIX A TROUBLESHOOTING AND SERVICE This appendix contains information on servicing and maintaining the Model 5850v2 Gyratory Compactor...

Страница 78: ...the circuit breaker is not tripped Moving parts are not moving 1 1 Ensure the unit is turned on 2 2 Check that the chamber door is closed 3 3 A switch may be broken Check the service panels and emerg...

Страница 79: ...erlabs com General calibration problems 1 1 Check all cable connections 2 2 For the height calibration ensure that the puck specimen papers and height standard assembly are located properly on the low...

Страница 80: ...wer carriage plate including the mold positioning pins and ram head see Figure 2 2 View A on page 2 9 as well as the upper carriage assembly and upper puck plate View B with Bindoff or similar cleaner...

Страница 81: ...eplacement is necessary contact your Troxler representative Mold positioning pins in the lower carriage plate Check for wear or flattening Replace if necessary Pucks Ensure that the surfaces are reaso...

Страница 82: ...ce the hose and sleeve 6 6 Open the chamber door and examine each hydraulic hose for wear If the rubber cover is worn replace the hose EVERY 500 HOURS OF OPERATION OR ONCE A YEAR 1 1 Remove the right...

Страница 83: ...e connector see Figure 1 1 on page 1 7 2 2 Remove the four screws that secure the control panel 3 3 Carefully remove the control panel using care not to damage any of the cables connected to it 4 4 Th...

Страница 84: ...cations 110665 Gravity extruder 106989 Height standard assembly 116066 Mold assembly 100 mm 116069 Mold assembly 150 mm 116901 Model 5850v2 Manual of Operation and Instruction 108664 Power cord 13 A 1...

Страница 85: ...part model and serial number Part number serial number if applicable Is the unit part still under warranty Problem or difficulty you are having with the unit Shipment method to Troxler and for return...

Страница 86: ...Appendix A 10 NOTES...

Страница 87: ...Model 5850v2 Appendix B 1 B MENU MAP APPENDIX B MENU MAP This appendix provides a map of the menus in the Model 5850v2 Gyratory Compactor control software...

Страница 88: ...ion Mode 1 Gyrations 2 Specimen Height This indicates that the first two menu items under the Setup menu are View Settings and Change Settings When the Change Settings item is selected the compactor d...

Страница 89: ...cimen Height 2 of Gyrations 3 Height 4 Angle 5 Pressure 6 Mold Diameter Mold Diameter 1 150mm 2 100mm 3 4in 7 Post Gyrate Delay Post Gyrate Delay 1 Enable 2 Disable 3 Data Output Data Output 1 Output...

Страница 90: ...Calibration 1 Pressure 2 Height 3 Angle Offset 4 Print Calibration 6 Special Special 1 Clock Calendar Clock Calendar 1 Change Time 2 Change Date 3 Time Format Time Format 1 AM PM 2 24 Hour 4 Date For...

Страница 91: ...TIONS APPENDIX C SPECIFICATIONS This appendix provides environmental conditions and specifications for the Model 5850v2 Gyratory Compactor CONTENTS Environmental Conditions C 2 Electrical Specificatio...

Страница 92: ...ge 55 to 85 C Temperature 67 to 185 F Ambient Operating 10 to 50 C Temperature 50 to 122 F Altitude Rating 2000 meters maximum Main Supply Voltage 10 Fluctuation Pollution Degree 2 Installation Catego...

Страница 93: ...arity Baud rate 9600 Cable type RS 232 null modem 9 pin female 9 25 pin female USB Port A list of compatible USB memory devices and printers is available on the 5850v2 product page at www troxlerlabs...

Страница 94: ...Puck Weight 3 kg 6 6 lb Compaction Pressure 200 1000 kPa 29 145 psi Pressure Accuracy Meets or exceeds FHWA specifications Number of Gyrations Adjustable from 1 999 Angle of Gyration 0 00 3 0 0 02 de...

Страница 95: ...15 Batteries replacing A 7 Baud rate C 3 Bindoff ii 2 8 4 6 4 8 Cable Serial 1 8 USB 1 8 Calibration 4 1 Calibration constants 4 10 4 12 5 7 Menu 4 5 Pressure 4 2 4 6 Print 4 13 Problems A 3 Schedule...

Страница 96: ...3 12 GyroPave 3 13 Height standard assembly 1 8 4 11 Height versus gyration format 3 10 Height specimen 3 6 Home position 3 14 Humidity C 2 Hydraulic oil 1 12 C 4 A 5 A 2 Inspection 1 9 Installation c...

Страница 97: ...1 14 C 3 USB 1 3 1 14 C 3 Power Requirements C 3 Switch 1 8 2 4 Pressure 3 7 Accuracy C 4 Calibration 4 2 4 6 Compaction 1 5 C 4 Verification kit 1 8 4 6 Print Calibration 4 13 Printer 1 8 Puck 1 8 Ra...

Страница 98: ...6 Height calibration 4 2 4 10 Loading 2 13 Papers 1 8 2 11 Preparing 2 11 START key 2 2 Storage temperature C 2 Supply voltage fluctuation C 2 Switch EMERGENCY 1 4 2 2 Switch power 1 8 2 4 Target heig...

Страница 99: ...Model 5850v2 Index...

Страница 100: ...NOTES...

Страница 101: ...ractual or other written and signed agreement THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF AND THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR...

Страница 102: ...12...

Отзывы:

Похожие инструкции для 5850v2