1–8
UNPACKING AND INSPECTION
Upon receipt of the gauge from the factory, a complete inspection
and inventory should be performed. If the shipping case, any other
part of the container, and/or the gauge appears to be damaged,
notify the carrier and your Troxler Representative
immediately
.
For shipping to another location or back to the factory, save the box
and any packing material. For shipping instructions and regulations,
please see Appendix D.
Check to see if the following literature and components have been
included:
♦
Manual of Operation and Instruction
♦
Quick Reference Card
♦
Gauge Warranty
♦
Gauge Certificate
♦
Calibration Data Sheet
♦
Troxler Regulatory Update (contains required shipping
documents)
♦
Magnesium Reference Block
♦
Air Gap Spacer
♦
Charger/Adapter
♦
Power Adapter (for cigarette lighter)
♦
Keys for Handle Lock
Lift the gauge from the case and inspect the outside surface for
damage. Check the lock on the source rod handle and make sure the
keys fit. Remove the lock and check the source rod operation. It
should move up and down with little effort. Return the gauge to the
transport case. Remember to wear a dosimeter while working with
the gauge.