EM-LON Operating Manual / Leaflet no. M375EV4 (3/2013)

3

Product description 

4

Transport, storage and packaging

Delivery check

Check delivered items immediately after arrival for
transport damage and completeness. In case of any
damage or an incomplete shipment, inform the
shipping company and your TROX contact person
immediately.
A complete shipment includes:
• PCB
• 20-pin header
• Fixing material (4 distance pieces and 4 screws)
• Operating and installation manual

Transport on site

• If possible, take the expansion module in the

transport packaging up to the installation location.

• Do not remove the protective wrapping until just

before installation.

Storage

If you need to store the expansion module 
temporarily, make sure that the following conditions
apply:
• Leave the unit in its packaging and do not expose

it to the effects of weather.

Store the unit in a dry place and away from direct

sunlight.

• Temperature: –10°C to +70°C 

Maximum humidity: 90% (non-condensing)

Packaging

Properly dispose of packaging material.

Functional description

The EM-LON expansion module supplements the
EASYLAB base components (TCU3 controller or
TAM adapter module) with a LonWorks interface for
the purpose of linking rooms or individual volume
flow controllers to the central BMS.
The PCB contains terminals for the LonWorks 
network and a service pin push button with indicator
light. The PCB can be fitted to the TCU3 or TAM
main PCB using a header. 
To simplify diagnosis during commissioning the
expansion module is equipped with two additional
indicator lights that indicate data traffic on the 
LonWorks interface.
Standard network variables are used for the 
communication within the LonWorks infrastructure.
These variables ensure unambiguous data
exchange between the nodes. For commissioning, it
is necessary to link the network variables between
the nodes (binding). Project software is used to link
the outputs of a node to the inputs of other nodes.

Содержание EM-LON

Страница 1: ...Operating Manual Leaflet no M375EV4 3 2013 The art of handling air Operating and Installation Manual EASYLAB Expansion module EM LON LonWorks interface for EASYLAB TCU3 controllers and TAM adapter mo...

Страница 2: ...ion __________________ 5 Product overview and technical data ______ 5 Functional description ________________ 6 4 Transport storage and packaging ________ 6 5 LonWorks network variables ____________ 8...

Страница 3: ...le it is essential to read this operating and installation manual before starting any work and to comply with it The manual must be given to the facilities manager when handing over the system The fac...

Страница 4: ...he PCB Tighten the mounting screws and distance pieces only hand tight to avoid damage to the PCB or to the fixing points in the casing Foreign matter and liquids If liquid gets onto the PCB or inside...

Страница 5: ...LON B LON A SH SH LON A LON B Technical data Supply voltage 5 V DC from the TCU3 controller or TAM adapter module Communication LonWorks transceiver FTT 10A Free Topology Twisted Pair Acceptable tempe...

Страница 6: ...e and away from direct sunlight Temperature 10 C to 70 C Maximum humidity 90 non condensing Packaging Properly dispose of packaging material Functional description The EM LON expansion module suppleme...

Страница 7: ...s_p x x Differential pressure setpoint value for the room nvoPressAct SNVT_press_p x x Differential pressure actual value for the room nvoLocalAlarm SNVT_switch x x x x x Single controller alarm nvoSu...

Страница 8: ...nd outputs TCU3 Overview of additional data points for EM LON LonWorks interface firmware version 2 0 and TCU firmware version 3 0 Name of variable Data type FH RR TAM RR RMF TAM RMF Meaning nviSC_Loc...

Страница 9: ...DampPosMin_FH nvoDampPosMin_RE nvoDampPosMin_RS nvoDampPosMin_TE nvoLocalAlarm nvoManOverride nvoMode nvoOccCmd nvoManOverride_R nvoMode_R nvoOccCmd_R nvoPressAct nvoPressAlarm nvoPressSet nvoSummaryA...

Страница 10: ...pieces 1 into the corresponding openings in the TCU3 or TAM main PCB and tighten them hand tight only Step 2 Take the pin header 2 and push it from below through the EM LON PCB 3 just far enough such...

Страница 11: ...d the holes for the distance pieces are above the distance pieces Then press the PCB onto the distance pieces In case the positions do not exactly line up check whether the pin header is still correct...

Страница 12: ...work Depending on the network topology controllers at the end of a chain may be connected to one bus controllers at other positions in the chain may be connected to two buses Strip the insulation from...

Страница 13: ...ommissioning Press the service pin push button and download the software for the EASYLAB LonWorks node The software for the EM LON expansion module is available for download on our website 2 Binding C...

Страница 14: ...EM LON Operating Manual Leaflet no M375EV4 3 2013 14...

Страница 15: ...EM LON Operating Manual Leaflet no M375EV4 3 2013 15...

Страница 16: ...EM LON Operating Manual Leaflet no M375EV4 3 2013 16...

Отзывы: