background image

Safety instructions

 CAUTION!

To use the masks, observe the following points:

The mask and insert filter must be suitable
for the application.

Breathing protection may not be used if
the concentration, type and characteris-
tics of the contaminants are not known.

The mask must never be used in envi-
ronments with less than 17% oxygen
(recommendation 

19.5%).

Do not use the mask if facial hair in the area
of the sealing rim prevents the mask from
forming a seal.

Insert the insert filter correctly and attach the
mask as instructed.

Wear the filter mask for the entire duration of
time spent in the risk zone.

Replace the insert filter:

when there is increased breathing
resistance

at the end of your shift.

If the mask gets damaged, leave the risk
zone immediately and replace the mask.

Never carry out any modifications or repairs
to the mask.

 WARNING!

Leave the risk zone immediately if:

breathing becomes difficult

if you experience dizziness or other com-
plaints

the mask gets damaged.

If you begin to smell or taste the hazardous
substance or encounter any irritation.

Material

Mask material: 65% polyester / 35% cotton

Straps: boil-proof synthetic rubber

Insert filter: prefilter and primary filter made
from 100% polypropylene, meltblown

Nose piece: polyethylene

Bearing

Please note:

Store the mask only in its original packaging

Store away from weather and direct sunlight.

Protect the product from humidity, dust and
contamination

Storage temperature: -20 °C to 25 °C.

Relative humidity: 80 % max., no condensation

Aging resistance

After a storage life of 5 years, the masks may no
longer be used.

Cleaning and disinfection

After each use, wash the masks without insert filter
at 60 degrees and then dry them fully. The filter
mask can be used 50 times; after this it must be
disposed of. The insert filters may not be washed or
re-used.

Disposal

Dispose of used insert filters and masks with the
household waste in accordance with national regu-
lations.

Safety instructions

 

X filter mask with insert filter in accordance with testing principles for Corona SARS-Cov-2 pandemic breathing masks

(CPA)

2

Отзывы: