background image

Decentralised
ventilation units

SCHOOLAIR-S-HV

Installation and operating manual

Read the instructions prior to performing any task!

Freestanding supply and extract air unit
with control FSL-CONTROL III (optional)

GB/en

Содержание SCHOOLAIR-S-HV

Страница 1: ...lised ventilation units SCHOOLAIR S HV Installation and operating manual Read the instructions prior to performing any task Freestanding supply and extract air unit with control FSL CONTROL III option...

Страница 2: ...H 2022 TROX GmbH Heinrich Trox Platz 47504 Neukirchen Vluyn Germany Phone 49 0 2845 2020 Fax 49 0 2845 202265 E mail trox de troxgroup com Internet http www troxtechnik com 11 2022 Decentralised venti...

Страница 3: ...ing electrical connections 21 6 4 1 Connecting the supply voltage 23 6 4 2 Connection of the control panel 23 6 4 3 Connection of room temperature sensor 25 6 4 4 Connection of external inputs and out...

Страница 4: ...ations in this manual are mainly for information and may differ from the actual design Other applicable documentation Installation and configuration manual FSL CON TROL III for units with FSL CONTROL...

Страница 5: ...g LEDs Display Screen elements e g buttons or menus 1 3 TROX Technical Service To ensure that your request is processed as quickly as possible please keep the following information ready Product name...

Страница 6: ...ve corrosive combustible or hazardous to health Operation in rooms where the humidity is perma nently high 90 Operation outdoors Use for enforced ventilation Operation without air filters 2 2 Safety s...

Страница 7: ...ual and unless the system owner has specifically agreed to them Instruction is provided by the HVAC contractor when the system is handed over Facility managers are responsible for cleaning the unit fo...

Страница 8: ...ctive equipment Safety shoes Safety shoes protect the feet against crushing falling parts and from slipping on slippery ground Safety Qualified staff Personal protective equipment Decentralised ventil...

Страница 9: ...equency 50 60 Hz Rating 3640 VA Power consumption nominal volume flow rate 160 W Protection level IP 21 Width 1200 mm Height 2300 mm Depth 600 mm Volume flow rate 300 500 800 m h boost 1050 m h Nomina...

Страница 10: ...at the cable penetration for the supply voltage Fig 1 Rating plate example Device type Year of manufacture Commission no Serial number Supply voltage Max power consumption Protection level Max water t...

Страница 11: ...spection access door top 9 Inspection access door bottom 10 Extract air filter ISO coarse 90 11 Rotary heat exchanger inside 12 Matching rear frame bottom 13 Feet 14 Casing mounting base 15 Supply air...

Страница 12: ...heat recovery 6 Fan supply air and extract air 7 Electric air heater 8 Supply air temperature sensor 9 Extract air filter ISO coarse 90 10 CO2 sensor optional SEH Single room exhaust air SET Single r...

Страница 13: ...extract air filter then flows through the heat recovery unit the extract air fan and the motorised shut off damper before it is dis charged to the outside as exhaust air The supply air is discharged...

Страница 14: ...nstallation site 6 Installation on page 16 In the process the serial number of the devices must be observed Chapter 3 2 Rating plate on page 10 Only join components with the same serial number Accesso...

Страница 15: ...rom dust and contamination Do not store the product below 25 C or above 55 C 5 6 Handling packaging materials Properly dispose of packaging material ENVIRONMENT Environmental damage due to improper di...

Страница 16: ...be performed by others fixing connection and sealing material to be provided by others Install the unit only on structural elements that can carry the load of the unit Use only certified fixing system...

Страница 17: ...by loosening the screws Fig 8 2 Remove the inspection access door Fig 9 1 and store it for later assembly keep the spacer plates Fig 8 3 and the slide disc Fig 8 4 Fig 11 Dismantling the cover grille...

Страница 18: ...8 and 9 are not required for assembly which can reduce the weight of the top of the device by approx 25 kg Fig 13 Cover grille with sound attenuator on the supply air fan 7 Loosen the four screws Fig...

Страница 19: ...the device on the back or on the side parts observe the lifting force Then lift the top part onto the mounting base with at least 2 people While doing this one hand on each side of the vacuum cups and...

Страница 20: ...device 12 Reassemble the dismantled components on the top of the device by carrying out steps 3 to 10 in reverse order Do not refit the matching rear frame to the top of the device step 2 Fig 18 Posi...

Страница 21: ...tching rear frame in the middle with the screw Fig 21 4 6 3 Connecting the ductwork The connection for outdoor air and exhaust air is made via two spigots 250 mm Chapter 4 1 Ventilation unit overview...

Страница 22: ...TROX follow the instructions of the controls provider Personnel Skilled qualified electrician DANGER Danger of electric shock Do not touch any live com ponents Electrical equipment carries a dangerous...

Страница 23: ...aught could occur in the conduit and affect the measurement results Schneider digital GND 6 24VDC 5 B 13 A 14 GS 15 X2 RS 485 N L PE Output Input N L RD BK 4 SH 3 GS 2 B 1 A Slave SH B GS A 2 2 2 3 1...

Страница 24: ...2515 2 LiYCY 5 x 0 5 mm shielded by others Schneider without selector switch X9 1 2 3 4 5 21 LED RET 16 LED 5VDC 14 SET PT 13 SNSR BUTTON SETPT RT 12 SNSR BUTTON 11 22 1 2 Fig 28 Wiring of control pan...

Страница 25: ...s Thermokon without selector switch without set point value adjuster Gira E2 X9 1 2 3 4 5 5 4 3 2 1 9 1 2 11 12 10 Fig 31 Wiring of Thermokon control panel to terminal X9 1 Control panel without selec...

Страница 26: ...ff Automatic 6 PIR sensor Valid oper ating mode Occupied 1 cable break safety device External switch outputs X5 7 6 5 4 3 2 1 X6 GND GND GND GND GND GND 1 Fig 34 Wiring example B alarm 1 Connecting ca...

Страница 27: ...S 2 B 1 A R 120 Fig 35 FSL CONTROL III Communication with 2 devices Master Slave Slave X2 RS 485 4 SH 3 GS 2 B 1 A R 120 X1 RS 485 4 SH 3 GS 2 B 1 A R 120 X1 RS 485 4 SH 3 GS 2 B 1 A Fig 36 FSL CONTRO...

Страница 28: ...e devices can also be connected to the building automation machine control device if the wiring is structured i e Modbus TCP or BACnet IP BAS MCD to master device with Modbus TCP BACnet IP X7 RJ 45 Fi...

Страница 29: ...nnection of BAS MCD to slave device with Modbus TCP 1 Network cable at least Cat 5e with connector RJ45 by others 2 Interface X7 in terminal box Installation Making electrical connections Communicatio...

Страница 30: ...master controller in the factory Fig 41 FSL CONTROL III network configuration example Modbus RTU BACnet MS TP If the master controller is integrated with a BAS MCD by others it acts as a slave within...

Страница 31: ...controls from TROX follow the instructions of the controls provider 7 3 X TAIRMINAL TROX X TAIRMINAL is a project specific software for visualisation operation and monitoring of ventilation systems on...

Страница 32: ...lave device the same information is displayed on the master device and the slave device If the slave device is connected to the master the supply air temperature and the valve positions are displayed...

Страница 33: ...rame and select the respective data point The display takes place as a diagram or as a csv file export Fig 47 Trending j Definition of the time period k Selection of the data points l Configuration of...

Страница 34: ...RF04 PSTD NTC20k 5k FS5 gn 5V SA part number A00000082515 Fan stage selector Push button LED Setpoint value adjuster Fig 50 Control panel without selector switch for sur face mounting type Schneider S...

Страница 35: ...part number A00000079779 Push button LED Setpoint value adjuster Fig 54 Control panel without selector switch for flush mounting suitable for Berker Q 3 switch range type WRF07 PTD NTC20k BType6 5k gn...

Страница 36: ...erating mode Off Actual values Display of the entire unit status various settings and numerous measured values Messages Display of the alarm messages Room temperature Displays the actual room temperat...

Страница 37: ...roller Press or briefly to switch between the fan stages Manual ventilation at the lowest speed fan stage Manual ventilation control at a medium level Manual ventilation at the highest speed fan stage...

Страница 38: ...tion Occupied V is activated the unit ventilates exclusively with outside air fresh air Unoccupied The Unoccupied mode is used for unoccupied rooms Fresh air Occupied V fresh air is selected if the ro...

Страница 39: ...ating mode RTC BAS MCD Unoccupied LED off Overtime LED on Boost Manual function for the quick ventilation of the room Switch on Press the Occupancy button 2 5 seconds Switch off Press the Occupancy bu...

Страница 40: ...Operation Control panel Analogue control panel settings Decentralised ventilation units SCHOOLAIR S HV 40...

Страница 41: ...units have to be cleaned Cleaning Cleaning intervals to VDI 6022 Clean all surfaces with a damp not wet cloth Use only common household cleaners do not use any caustic scouring or otherwise aggressive...

Страница 42: ...a year or if it does no longer meet the technical or hygiene requirements replace it When you insert a new filter make sure that the labelling at the front of the filter remains visible Observe the d...

Страница 43: ...lf cleaning not suffice you may clean the heat recovery unit with compressed air intervals depend on the degree of contamination In the event of heavy contamination or a defect the rotary heat recover...

Страница 44: ...mponents to prevent them from falling or toppling When in doubt contact the manufacturer 10 1 2 Disassembly Before you start disassembly Switch off the unit and secure it against being switched on acc...

Страница 45: ...11 Lists of replacement parts 11 1 Replacement parts list 20 Fig 59 SA S HV replacement parts Lists of replacement parts Replacement parts list Decentralised ventilation units SCHOOLAIR S HV 45...

Страница 46: ...lt A00000093203 8a Drive belt of rotor A00000094965 8b Actuator with drive wheel A00000081838 9 Actuator for exhaust air damper M466EQ6 10 Controller FSL CONTROL III A00000075513 11 Power supply unit...

Страница 47: ...ery unit Cleaning 43 Hygiene inspection 41 I Incorrect use 6 L Lists of replacement parts 45 M Maintenance 41 O Operation 34 Outdoor air filter Checking 41 Replacing 41 P Packages Transport 14 Packagi...

Страница 48: ...Appendix Appendix Decentralised ventilation units SCHOOLAIR S HV 48...

Страница 49: ...n case of a power failure X Checking filters after any pres sure drop based on hygiene con ditions based on operating time random checks Replace the filter medium clean the filter chamber check seals...

Страница 50: ...Next maintenance scheduled for Signature Technician Company Stamp Commissioning report Maintenance report Decentralised ventilation units SCHOOLAIR S HV 50...

Страница 51: ...body measurements Part 2 Principles for determining the dimensions required for access openings EN 547 3 1996 A1 2008 Safety of machinery Human body measurements Part 3 Anthropometric data EN 1005 3 2...

Страница 52: ...C Product information according to ErP directive C 1 Product information SCHOOLAIR S HV Product information according to ErP direct Decentralised ventilation units SCHOOLAIR S HV 52...

Страница 53: ...Zur Erstellung der vorliegenden Konformit tserkl rung wurde jeweils ein Muster der oben genannten Serie im Werk gepr ft sowie die verschiedenen Datenbl tter technische Dokumentationen und Pr fberichte...

Страница 54: ...Decentralised ventilation units SCHOOLAIR S HV 54...

Страница 55: ...Decentralised ventilation units SCHOOLAIR S HV 55...

Страница 56: ...TROX GmbH 2022 TROX GmbH Heinrich Trox Platz 47504 Neukirchen Vluyn Germany Phone 49 0 2845 2020 Fax 49 0 2845 202265 E mail trox de troxgroup com http www troxtechnik com...

Отзывы: