General information

About this supplementary operating manual

This supplementary operating manual describes the fol-

lowing explosion-proof variants of the fire damper:

FKRS-EU with spring return actuator

ExMax-15-BF-TR

FKRS-EU with spring return actuator

RedMax-15-BF-TR

To ensure correct functioning of the fire damper, it is

essential to read the provided supplementary operating

manual before starting any work, and to comply with it.

This supplementary operating manual must be given to

the system owner when handing over the system. The

system owner must include the supplementary oper-

ating manual with the system documentation.

The manufacturer does not accept any liability for any

malfunction or damage resulting from non-compliance

with this supplementary operating manual or non-com-

pliance with relevant statutory regulations.

This supplementary operating manual is intended for

specialist consultants, developers, and owners of the

ventilation systems in which the fire dampers are to be

installed. This operating manual is also intended for

people conducting the following work:

Electrical connection

Commissioning

Functional test

Other applicable documentation

In addition to this supplementary operating manual, the

following documents apply:

Operating and installation manual FKRS-EU

ATEX declaration of conformity

EPS 21 ATEX 2 142 X

Symbols used in this manual

 DANGER!

Imminently hazardous situation which, if not avoided,

will result in death or serious injury.

 WARNING!

Potentially hazardous situation which, if not avoided,

may result in death or serious injury.

 CAUTION!

Potentially hazardous situation which, if not avoided,

may result in minor or moderate injury.

 NOTICE!

Potentially hazardous situation which, if not avoided,

may result in property damage.

General information

 

 

Explosion-proof fire damper Type FKRS-EU

4

Содержание FKRS-EU Series

Страница 1: ...Explosion proof fire damper Type FKRS EU Supplementary Operating Manual Read the instructions prior to performing any task according to Declaration of Performance DoP FKRS EU DE 004 GB en...

Страница 2: ...original 2021 TROX GmbH Heinrich Trox Platz 47504 Neukirchen Vluyn Germany Germany Phone 49 0 2845 2020 Fax 49 0 2845 202 265 E mail trox de troxgroup de Internet http www troxtechnik com 12 2021 Exp...

Страница 3: ...data 6 3 1 FKRS EU with explosion proof spring return actuator 6 3 2 ATEX areas of application 7 4 Electrical connection 8 5 Functional test 10 5 1 FKRS EU with ExMax or RedMax spring return actuator...

Страница 4: ...nt statutory regulations This supplementary operating manual is intended for specialist consultants developers and owners of the ventilation systems in which the fire dampers are to be installed This...

Страница 5: ...components according to the local electronic waste regulations Correct use The fire damper is used as a shut off device to prevent fire and smoke from spreading through ducting in areas with potentia...

Страница 6: ...ght kg Nominal size DN 100 125 150 160 180 200 224 250 280 315 D 99 124 149 159 179 199 223 249 279 314 Weight with spring return actuator 4 8 5 1 5 3 5 5 5 8 6 0 6 2 6 8 7 3 7 9 Spring return actuato...

Страница 7: ...ExMax 15 BF TR II 2G Ex h IIC T6 Gb II 2D Ex h IIIC T80 C Db 40 C Ta 40 C 10 m s ExPro TT ExMax 15 BF TR II 2G Ex h IIC T5 Gb II 2D Ex h IIIC T95 C Db 40 C Ta 50 C 10 m s ExPro TT RedMax 15 BF TR II...

Страница 8: ...on Functional testing requires a switch that interrupts the voltage supply by others The electrical connection is made in the terminal box The factory installed wiring must not be changed Attention If...

Страница 9: ...Wiring example for TROXNETCOM Fig 3 Wiring example for TROXNETCOM 1 Controller 2 AS EM C module 3 FKRS EU 4 Safe area Electrical connection Explosion proof fire damper Type FKRS EU 9...

Страница 10: ...2 Damper blade is open Closing opening the fire damper with spring return actuator Fig 5 Thermoelectric release mechanism ExPro TT 1 Push button for functional test Fig 6 Functional test FKRS EU with...

Страница 11: ...de will not close To re establish its function connect the power supply Requirement The damper blade is CLOSED 1 Remove the terminal box 1 2 Insert the crank handle 2 into the opening for the spring w...

Страница 12: ...Explosion proof fire damper Type FKRS EU 12...

Отзывы: