Important notes

Information on the installation manual

This manual enables operating or service personnel
to correctly install the product described below and
to use it safely and efficiently.

It is essential that these individuals read and fully
understand this manual before starting any work.
The basic prerequisite for safe working is to comply
with the safety notes and all instructions in this
manual.

The local regulations for health and safety at work
and general safety regulations also apply.

Qualified staff

The work described in this manual has to be carried
out by individuals with the qualification, training,
knowledge and experience described below:

HVAC technician

HVAC technicians are individuals who have suffi-
cient professional or technical training in the field
they are working in to enable them to carry out their
assigned duties at the level of responsibility allo-
cated to them and in compliance with the relevant
guidelines, safety regulations and instructions.
HVAC technicians are individuals who have in-
depth knowledge and skills related to HVAC sys-
tems; they are also responsible for the professional
completion of the work under consideration.

HVAC technicians are individuals who have suffi-
cient professional or technical training, knowledge
and actual experience to enable them to work on
HVAC systems, understand any potential hazards
related to the work under consideration, and recog-
nise and avoid any risks involved.

Limitation of liability

The information in this manual has been compiled
with reference to the applicable standards and
guidelines, the state of the art, and our expertise
and experience of many years.

The manufacturer does not accept any liability for
damages resulting from:

Non-compliance with this manual

Incorrect use

Operation or handling by untrained individuals

Unauthorised modifications

The actual scope of delivery may differ from the
information in this manual for special constructions,
additional order options or as a result of recent
technical changes.

Copyright

This document, including all illustrations, photos,
etc., is protected by copyright.

Any use of this document without the written con-
sent of the manufacturer is an infringement of copy-
right; this applies in particular to disclosing this
document to third parties, to publishing, copying,
microcopying, or translating content, and to saving
content on electronic systems or modifying it.

Violators will be held liable for any damage. The
right to further claims remains reserved.

Personal protective equipment

Personal protective equipment must be worn for
any work in order to reduce health or safety haz-
ards to the minimum.

The appropriate protective equipment for a job must
be worn for as long as the job takes.

Correct use

Non-return dampers are used to prevent air from
flowing against the intended airflow direction. They
open and close automatically and are used for
supply air or extract air in ventilation and air condi-
tioning systems.

Important notes

 

Non-return dampers Types UL, KUL, WG-KUL, ARK, ARK-1

2

Содержание ARK series

Страница 1: ...e mesh with or without insect screen Casing Blades Seal Linkage Travel stop angle section Adjustable blade restrictor Installation manual GB en Non return dampers Types UL KUL WG KUL ARK ARK 1 TROX GmbH Heinrich Trox Platz 47504 Neukirchen Vluyn Germany Phone 49 0 2845 2020 Fax 49 0 2845 202265 E mail trox trox de http www troxtechnik com A00000053072 10 2018 TROX GmbH 2015 Non return dampers Type...

Страница 2: ...cog nise and avoid any risks involved Limitation of liability The information in this manual has been compiled with reference to the applicable standards and guidelines the state of the art and our expertise and experience of many years The manufacturer does not accept any liability for damages resulting from Non compliance with this manual Incorrect use Operation or handling by untrained individu...

Страница 3: ...d thin sheet metal parts may cause cuts or grazes Be careful when carrying out any work Wear protective gloves safety shoes and a hard hat Use only lifting and transport gear designed for the required load Always secure the load against tip ping and falling Upon delivery carefully remove the packaging and check the damper for transport damage and com pleteness Storage Please note Store the unit on...

Страница 4: ...ts Note the airflow direction Duct connection on one side or on both sides with UL only on one side Dampers that are not screw fixed to the wall or ceiling slab require suspensions The function of the damper must be checked before installation General installation information Fig 2 Installation types Ducts on both sides only with KUL ARK 1 Without duct air transfer Duct on one side air outlet Duct...

Страница 5: ...th factory mounted external weather louvre Fig 4 Wall installation UL1 Extract opening UL2 Supply opening Note the airflow direction blade opening direction Installation opening H1 B1 Without installation sub frame H 15 B 15 With installation sub frame H 35 B 35 Fix the damper with suitable screws by others flange holes 9 mm Installation Non return dampers Types UL KUL WG KUL ARK ARK 1 5 ...

Страница 6: ...allation subframe KUL shown Fig 6 Duct installation KUL shown Fix the damper with suitable screws by others flange holes 9 5 mm Fig 7 Installation with installation subframe WG KUL 1 shown Threaded stud Fixing tab Installation subframe Items 1 to 3 are included in the installation sub frame supply package Installation opening H1 B1 Without installation sub frame H 95 B 95 With installation sub fra...

Страница 7: ... exhaust air or fresh air damper Fig 8 Horizontal airflow Fig 9 Vertical airflow Fig 10 Wall installation without installation sub frame ARK 1 shown Blade movement area must be kept clear Fig 11 Duct installation ARK 1 shown Blade movement area must be kept clear Installation Non return dampers Types UL KUL WG KUL ARK ARK 1 7 ...

Страница 8: ...Threaded stud Fixing tab Installation subframe Items 1 to 3 are included in the installation sub frame supply package Installing the installation subframe Fig 13 Installation subframe and damper assembly Threaded stud Washer Hexagon nut Fixing tab Hexagon head screw Installation subframe Damper casing Installation Non return dampers Types UL KUL WG KUL ARK ARK 1 8 ...

Страница 9: ...oning and maintenance Commissioning Personnel HVAC technician As part of commissioning the non return damper must be tested for correct functioning NOTICE Start up of fans with UL KUL Ensure a gradual start up of fans to avoid a sudden pressure increase NOTICE ARK 1 blade restrictors Type ARK 1 non return dampers have adjustable blade restrictors which can be adjusted as part of commissioning Main...

Страница 10: ...ature galvanised steel 0 80 C Operating pressure galvanised steel with optional Viton seal 0 120 C Operating pressure stainless steel with optional Viton seal 0 200 C Total differential pressure at 10 m s horizontal airflow 115 Pa Differential pressure at 2 m s vertical airflow 135 Pa Differential pressure at 10 m s vertical airflow 45 Pa Closed blade air leakage against the intended airflow direc...

Страница 11: ...Non return dampers Types UL KUL WG KUL ARK ARK 1 11 ...

Страница 12: ...Non return dampers Types UL KUL WG KUL ARK ARK 1 12 ...

Отзывы: