background image

EN

5

submerged waste water pump TWP 4036 E / TWP 7536 E / TWP 9000 ES / TWP 11000 ES

Staying in water prohibited

This symbol indicates that the device must not be
operated with persons or animals in the water.

Do not use at freezing temperatures

This symbol indicates that the device must be protected
from frost.

Keep out of the reach of children – not a toy

This symbol indicates that the device is not a toy and is
thus not suitable for children.

Do not pull the mains plug by the power cable

This symbol indicates that you must not pull the mains
plug out of the socket by the power cable.

Pull the mains plug

This symbol indicates that the mains plug must be
removed from the socket when the device is not in use.

Not suitable for pumping potable water

This symbol indicates that the device is not suitable for
pumping potable water.

Submerge pump at a slight angle

This symbol indicates that the pump must be
submerged into the water at a slight angle to allow the
remaining air to escape.

Residual risks

Warning of electrical voltage

Work on the electrical components must only be
carried out by an authorised specialist company!

Warning of electrical voltage

Before any work on the device, remove the mains plug
from the mains socket!
Do not touch the mains plug with wet or damp hands.
Hold onto the mains plug while pulling the power cable
out of the mains socket.

Warning

Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way!
Observe the personnel qualifications!

Warning

The device is not a toy and does not belong in the
hands of children.

Warning

Risk of suffocation!
Do not leave the packaging lying around. Children may
use it as a dangerous toy.

Note

If you store or transport the device improperly, the
device may be damaged.
Note the information regarding transport and storage of
the device.

Behaviour in the event of an emergency

1. In an emergency, disconnect the device from the mains

feed-in: Hold onto the mains plug while pulling the power
cable out of the mains socket.

2. Do not reconnect a defective device to the mains.

Overheating protection

The device is provided with a thermal protection circuit which is
activated by overheating of the device and then switches the
device off.
Switch the device off and let it cool down. Investigate the cause
of overheating. Should the problem persist, please contact the
customer service.

Information about the device

Device description

The submerged waste water pump is suited for draining,
conveying and pumping over clear water with the contained
suspended matter not exceeding a maximum particle size of 25
mm.
A float ensures the automatic switch-on and switch-off at a
respectively defined height. Additionally, the switch-on/-off
height can be finely adjusted within the specified range by
means of a locking device, see technical data.
The water temperature must not exceed 35 °C.
Hoses with an inner diameter of 25 mm or 38 mm can be
connected to the supplied reducer. Pipe or hose connections
with a G1½" / DN25 internal thread can also be connected to
the reducer, and pipe or hose connections with a G1½" / DN40
internal thread can be connected to the elbow which is also
supplied.
For quick installation and uninstallation, the device is equipped
with a connection for the "Quick Connect" connection system.
The pump housing of the models TWP 4036 E and TWP 7536 E
is made of plastic. The pump housing of the models
TWP 9000 ES and TWP 11000 ES is made of stainless steel.

Info

The illustrations in this operating manual feature the
models TWP 4036 E and TWP 7536 E by way of
example. However, the depicted operating steps and
explanations also apply to the devices TWP 9000 ES
and TWP 11000 ES unless otherwise mentioned.

Содержание TWP 11000 ES

Страница 1: ...TRT BA TWP4036E TWP7536E TWP9000ES TWP11000ES TC2020 50 001 EN TWP 4036 E TWP 7536 E TWP 9000 ES TWP 11000 ES EN OPERATING MANUAL SUBMERGED WASTE WATER PUMP ...

Страница 2: ...al word indicates important information e g material damage but does not indicate hazards Info Information marked with this symbol helps you to carry out your tasks quickly and safely Follow the manual Information marked with this symbol indicates that the operating manual must be observed You can download the current version of the operating manual and the EU declaration of conformity via the fol...

Страница 3: ...mages on the mains plug or power cable If the connection line of this device is damaged the device must be sent for recycling in accordance with the specifications provided in the Disposal chapter Defective power cables pose a serious health risk Should there be a risk of flooding install the plug connections in a flood proof area There is a risk of electric shock Make sure that the mains voltage ...

Страница 4: ...ted The device is not suitable as permanent automatic overflow protection of e g wells or fountains or for the regulation of the groundwater level Use a stationary waste water pumping system for building and property drainage for these purposes The device is not suitable for increasing the pressure of existing water supply networks The device is not suitable for pumping potable water The device mu...

Страница 5: ...he device may be damaged Note the information regarding transport and storage of the device Behaviour in the event of an emergency 1 In an emergency disconnect the device from the mains feed in Hold onto the mains plug while pulling the power cable out of the mains socket 2 Do not reconnect a defective device to the mains Overheating protection The device is provided with a thermal protection circ...

Страница 6: ...chment for nylon cord 2 Connection for connection system 3 Float switch locking device 4 Float switch 5 Power cable 6 Air intake opening with cover panel 7 Reducer 8 Elbow Connection options No Designation a Hose connection for an inner diameter of 25 mm with hose clamp b Hose connection for a G1 DN25 internal thread c Hose connection for an inner diameter of 38 mm with hose clamp d Hose connectio...

Страница 7: ...er Assembly and installation Scope of delivery 1 x Submerged clear water pump 1 x Reducer for hoses with inner diameters of 25 mm or 38 mm as well as hose connections with G1 DN25 internal thread 1 x elbow for hose connections with G1 DN40 internal thread 1 x Nylon cord 10 m 1 x Manual Unpacking the device 1 Open the cardboard box and take the device out 2 Completely remove the packaging 3 Fully u...

Страница 8: ... connection or hose connection with internal thread 1 Screw the pipe connection or hose connection internal thread G1 DN25 onto the reducer 7 7 8 Alternatively you can also screw the pipe connection or hose connection with the internal thread G1 DN40 directly onto the elbow 8 Installing the connection system 1 Press the red button on the elbow 8 2 Push the elbow 8 onto the pump connection 2 2 8 In...

Страница 9: ...ce to run dry This would damage the pump Make sure that the float switch 4 is able to move freely and does not suffer from a limited mobility caused by obstacles Observe a sufficient distance between float switch 4 and float switch locking device 3 for this could prevent the automatic switch off causing the device to run dry Make sure that the position of float switch 4 is adjusted in a way that i...

Страница 10: ...the mains socket for its proper condition The mains socket s fusing must be sufficient Make it impossible for moisture to reach mains plug or socket There is a risk of electric shock Warning of electrical voltage Electric shock from damaged power supply cable Make sure not to hold or suspend the device by the power supply cable under any circumstances Note At the bottom of ponds and other waterbod...

Страница 11: ...the maximum switch on height ð The device will be switched off as soon as the float switch reaches the set or the minimum switch off height Info Once the device has been switched off any water still remaining in the line can flow back through the device Manual operation You can also use the device in manual operation In manual operation it is possible to siphon off the media to a residual height o...

Страница 12: ...ns plug into a sufficiently fused mains socket ð The device switches on 7 Oversee the pumping process 8 When the device starts to suck in air disconnect the power cable from the mains socket by holding onto the mains plug Info If the device switches off again after only a brief period of operation the float switch might have come loose Fix the float switch again as depicted Shutdown Warning of ele...

Страница 13: ...inimum water level Check whether the hoses are blocked and whether the water contains any suspended matter with a particle size of more than 25 mm which could clog up the device Check whether the used hose diameter is too small Check whether the hose line is kinked or blocked Remove kinks and or blockages Check whether the reducer 7 and or elbow 8 are clogged The device is not switching off automa...

Страница 14: ... on the device Check the safety signs and labels attached to the device at regular intervals Replace illegible safety signs Cleaning Clean the device with a soft damp and lint free cloth Protect electrical components from moisture Do not use any aggressive cleaning agents such as cleaning sprays solvents alcohol based or abrasive cleaners to dampen the cloth Disconnect the connection line Rinse th...

Страница 15: ...50 W 900 W 1100 W Type of protection IPX8 IPX8 IPX8 IPX8 Minimum operating depth 85 mm 85 mm 50 mm 50 mm Max water level after suction 40 mm 40 mm 40 mm 40 mm Connection type CEE 7 4 CEE 7 4 CEE 7 4 CEE 7 4 Cable length 10 m 10 m 10 m 10 m Protection class I I I I Weight 4 kg 5 kg 5 5 kg 6 kg Dimensions length x width x height 220 x 160 x 340 mm 220 x 160 x 370 mm 225 x 225x 370 mm 225 x 225x 370 ...

Страница 16: ...1000 ES Schematic representation TWP 4036 E max 35 C 55 cm 12 cm max 5 m max 7 m TWP 4036 E TWP 7536 E max 35 C 60 cm 15 cm max 8 m max 7 m TWP 7536 E TWP 9000 ES max 35 C 60 cm 15 cm max 8 m max 7 m TWP 9000 ES TWP 11000 ES max 35 C 60 cm 15 cm max 9 m max 7 m TWP 11000 ES ...

Страница 17: ...l find collection points for free return of waste electrical and electronic equipment in your vicinity The addresses can be obtained from your municipality or local administration For further return options provided by us please refer to our website https de trotec com shop The separate collection of waste electrical and electronic equipment aims to enable the re use recycling and other forms of r...

Страница 18: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Отзывы: