EN
5
submerged waste water pump TWP 4036 E / TWP 7536 E / TWP 9000 ES / TWP 11000 ES
Staying in water prohibited
This symbol indicates that the device must not be
operated with persons or animals in the water.
Do not use at freezing temperatures
This symbol indicates that the device must be protected
from frost.
Keep out of the reach of children – not a toy
This symbol indicates that the device is not a toy and is
thus not suitable for children.
Do not pull the mains plug by the power cable
This symbol indicates that you must not pull the mains
plug out of the socket by the power cable.
Pull the mains plug
This symbol indicates that the mains plug must be
removed from the socket when the device is not in use.
Not suitable for pumping potable water
This symbol indicates that the device is not suitable for
pumping potable water.
Submerge pump at a slight angle
This symbol indicates that the pump must be
submerged into the water at a slight angle to allow the
remaining air to escape.
Residual risks
Warning of electrical voltage
Work on the electrical components must only be
carried out by an authorised specialist company!
Warning of electrical voltage
Before any work on the device, remove the mains plug
from the mains socket!
Do not touch the mains plug with wet or damp hands.
Hold onto the mains plug while pulling the power cable
out of the mains socket.
Warning
Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way!
Observe the personnel qualifications!
Warning
The device is not a toy and does not belong in the
hands of children.
Warning
Risk of suffocation!
Do not leave the packaging lying around. Children may
use it as a dangerous toy.
Note
If you store or transport the device improperly, the
device may be damaged.
Note the information regarding transport and storage of
the device.
Behaviour in the event of an emergency
1. In an emergency, disconnect the device from the mains
feed-in: Hold onto the mains plug while pulling the power
cable out of the mains socket.
2. Do not reconnect a defective device to the mains.
Overheating protection
The device is provided with a thermal protection circuit which is
activated by overheating of the device and then switches the
device off.
Switch the device off and let it cool down. Investigate the cause
of overheating. Should the problem persist, please contact the
customer service.
Information about the device
Device description
The submerged waste water pump is suited for draining,
conveying and pumping over clear water with the contained
suspended matter not exceeding a maximum particle size of 25
mm.
A float ensures the automatic switch-on and switch-off at a
respectively defined height. Additionally, the switch-on/-off
height can be finely adjusted within the specified range by
means of a locking device, see technical data.
The water temperature must not exceed 35 °C.
Hoses with an inner diameter of 25 mm or 38 mm can be
connected to the supplied reducer. Pipe or hose connections
with a G1½" / DN25 internal thread can also be connected to
the reducer, and pipe or hose connections with a G1½" / DN40
internal thread can be connected to the elbow which is also
supplied.
For quick installation and uninstallation, the device is equipped
with a connection for the "Quick Connect" connection system.
The pump housing of the models TWP 4036 E and TWP 7536 E
is made of plastic. The pump housing of the models
TWP 9000 ES and TWP 11000 ES is made of stainless steel.
Info
The illustrations in this operating manual feature the
models TWP 4036 E and TWP 7536 E by way of
example. However, the depicted operating steps and
explanations also apply to the devices TWP 9000 ES
and TWP 11000 ES unless otherwise mentioned.