submerged waste water pump TWP 4036 E / TWP 7536 E / TWP 9000 ES / TWP 11000 ES
4. Put the float switch locking device (
3
) from above into the
respective holder on the housing with the cable of the float
switch pointing downwards.
TWP 4036 E / TWP 7536 E
3
4
TWP 9000 ES / TWP 11000 ES
3
4
ð
With the float switch affixed in this position, the device
is switched on permanently.
5. Lower the device into the water at a slight angle to allow
any remaining air to escape. Make sure that the position of
the float switch does not change.
6. Plug the mains plug into a sufficiently fused mains socket.
ð
The device switches on.
7. Oversee the pumping process.
8. When the device starts to suck in air, disconnect the power
cable from the mains socket by holding onto the mains
plug.
Info
If the device switches off again after only a brief period
of operation, the float switch might have come loose.
Fix the float switch again as depicted.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
1. Hold onto the mains plug while pulling the power cable out
of the mains socket.
2. Pull the device out by means of the nylon cord.
3. Disconnect the connection line.
4. Clean the device according to the Maintenance chapter.
5. Store the device according to the Storage chapter.