Errors and faults
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
The device does not start:
•
Check the power connection.
•
Check the power cable and mains plug for damage.
•
Check the on-site fusing.
•
The device comes equipped with a tilt protection, it
switches off automatically when tilted. If the
Power
LED (
25
) is illuminated in red, check whether the
device is standing in an upright position and on a level
surface.
•
Check the condensation tank for correct seating.
•
Check the room temperature and the current room
humidity level. If the current room humidity level is below
the room humidity level set, the device will not switch on.
Observe the device's permissible operating range
according to the technical data.
•
At an ambient temperature above 36 °C, the heating is
switched off automatically making condensate formation
impossible.
•
Wait for 10 minutes before restarting the device. If the
device is not starting, have the electrics checked by a
specialist company or by Trotec.
The device is running, but there is no formation of
condensate:
•
Check the float in the condensation tank for dirt. If
necessary, clean the condensation tank. The float must be
able to move freely.
•
Check the room temperature and the current room
humidity level. If the current room humidity level is below
the room humidity level set, the device will not switch on.
Observe the device's permissible operating range
according to the technical data.
•
Ensure that the relative room humidity complies with the
technical data.
•
Check the air filter for dirt. If necessary, clean or replace
the air filter.
•
Check the air filter for dirt. If necessary, clean or replace
the air filter.
•
From the outside, check the condenser for dirt (see
chapter Maintenance). If the condenser is dirty, have it
cleaned by a specialist company or by Trotec.
The device is loud or vibrates:
•
Check whether the device is set up in a stable and upright
position.
Condensate is leaking:
•
Check the device for leaks.
The device gets very warm, is loud or is losing
performance:
•
Check the air inlets and air filters for dirt. Remove external
dirt.
•
From the outside, check the device for dirt (see chapter
Maintenance). If the inside of the device is dirty, have it
cleaned by a specialist company for cooling and air-
conditioning or by Trotec.
The device still does not operate correctly after these
checks:
Please contact the customer service. If necessary, bring the
device to a specialist company for cooling and air-conditioning
or to Trotec for repair.