10
EN
dehumidifier TTP 1 E / TTP 2 E
Activities required before starting maintenance
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
•
Switch the device off.
•
Hold onto the mains plug while pulling the power cable out
of the mains socket.
Warning of electrical voltage
Tasks which require the device to be opened must
only be carried out by authorised specialist
companies or by Trotec.
Cleaning the housing
Clean the housing with a soft, damp and lint-free cloth. Make
sure that no moisture enters the housing. Protect electrical
components from moisture. Do not use any aggressive cleaning
agents such as cleaning sprays, solvents, alcohol-based or
abrasive cleaners to dampen the cloth.
Visual inspection of the inside of the device for dirt
1. Use a torch to illuminate the openings of the device.
2. Check the inside of the device for dirt.
3. If you see a thick layer of dust, have the inside of the
device cleaned by a specialist company or by Trotec.
Emptying the condensation tank
If the condensation tank is full or the float is not correctly
positioned, the indicator LED (
7
) lights up red and the device
switches off.
1. Take the condensation tank (
3
) out of the device.
3
2. Empty the condensation tank (
3
) over a drain or sink.
3. Rinse the tank with clear water. Clean the tank regularly
using a mild cleaning agent (no detergent!).