dehumidifier TTK Qube

Exploded assembly drawing

Info

The position numbers of the spare parts differ from
those describing the positions of the components
mentioned in these instructions.

List of spare parts for 

TTK Qube

No. Spare part

No. Spare part

No. Spare part

1

Baseplate

13

Fan Speed Switch

25

Finned Pack Heat Exchanger

2

Housing

14

Condensates Pump Purge switch

26

Heat Exchanger Left Support

3

Air Outlet Grille

15

Hours + Energy Counter

27

Heat Exchanger Right Support

4

Air Inlet Grille

16

Humidistat

28

Insulating Foam Plate

5

Air Inlet Filter

17

Humidistat Knob

29

Fan

6

Plastic Grip

18

PCB

30

Fan plate

7

Control Panel

19

PCB Holder

31

Water Pan

8

Controls' Protection Bars

20

Controls Protection Box

32

Water Pan to Condensates Pump Hose

9

Controls' Sticker

21

Non-Marking Rubber Feet

33

Condensates Pump

10

Supply Cable

22

Compressor

34

Condensates Pump baseplate

11

Cable Retainer

23

Running Capacitor

35

Condensates Pump to Fitting Hose

12

I/0 Main Status LED

24

Defrost Valve

36

Condensates Outlet Fitting

Содержание TTK QUBE

Страница 1: ...TRT BA TTK QUBE TC2021 07 002 EN TTK QUBE EN ORIGINAL INSTRUCTIONS DEHUMIDIFIER...

Страница 2: ...before starting or using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warni...

Страница 3: ...ammable refrigerants Only position the device in rooms where potentially leaking refrigerant cannot accumulate Only position the device in rooms where there is no source of ignition e g open flames an...

Страница 4: ...o use this device must be aware of the dangers that occur when working with electric devices in damp areas have read and understood the instructions especially the Safety chapter Maintenance tasks whi...

Страница 5: ...cy 1 Switch off the device 2 In an emergency disconnect the device from the mains feed in Hold onto the mains plug while pulling the power cable out of the mains socket 3 Do not reconnect a defective...

Страница 6: ...ondensate from the device and the condensation drain hose see chapter Maintenance Do not use the power cable to drag the device After transporting the device proceed as follows Set up the device in an...

Страница 7: ...tion contact the customer service Only position the device in rooms where potentially leaking refrigerant cannot accumulate Only position the device in rooms where there is no source of ignition e g o...

Страница 8: ...itched off 1 Connect the condensation drain hose to the hose connection 2 Make sure that the condensation drain hose is properly connected to the device and free of damage 3 Depending on the applicati...

Страница 9: ...embly and start up you can switch it on 1 Switch the device on by setting the mains switch 11 to position I 2 Make sure that the mains switch button 11 is illuminated and that the status lamp 12 flash...

Страница 10: ...ls expose the device to extreme stresses Moreover drying is no longer economical at such high temperatures and also poses dangers for the inventory of the room to be dried Please note that the switch...

Страница 11: ...condensation drain hose is connected connect it if necessary If the condensation drain hose has already been connected check it for tightness The device is loud or vibrates Check whether the device i...

Страница 12: ...rews X X Test run X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Cleaning the condensate pump Check air inlets and outlets fo...

Страница 13: ...es if safe to do so P403 Store in a well ventilated place The entire refrigerant circuit is a maintenance free hermetically sealed system and may only be maintained or repaired by specialist companies...

Страница 14: ...wet filter into the device 4 Reinsert the air filter into the device Cleaning the inside with compressed air Warning Risk of injury caused by ejected compressed air upon activation of the compressed a...

Страница 15: ...5 35 C Operating range relative humidity 50 90 RH Max permissible pressure 1 8 MPa Pressure suction side 0 3 MPa Pressure outlet side 1 6 MPa Air volume flow 283 m h Mains connection 220 240 V 50 Hz...

Страница 16: ...16 EN dehumidifier TTK Qube Wiring diagram With operating hours counter and MID compliant energy meter...

Страница 17: ...Grille 15 Hours Energy Counter 27 Heat Exchanger Right Support 4 Air Inlet Grille 16 Humidistat 28 Insulating Foam Plate 5 Air Inlet Filter 17 Humidistat Knob 29 Fan 6 Plastic Grip 18 PCB 30 Fan plat...

Страница 18: ...ulations Declaration of conformity The text below sets out the contents of the declaration of conformity The signed declaration of conformity can be found at https hub trotec com id 44931 Declaration...

Страница 19: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Отзывы: