dehumidifier TTK 71 E
Emptying the condensation tank
If the condensation tank is full or not installed correctly, the
TANK FULL
indication (14) will light up on the control panel. The
compressor and fan will switch off.
1. Take the condensation tank out of the device.
2. Empty the condensation tank over a drain or sink.
3. Rinse the tank with clear water. Clean the tank regularly
using a mild cleaning agent (no detergent!).
4. Refit the condensation tank into the device.
Make sure not to damage the float when inserting or
removing the condensation tank.
In doing so, make sure that the float is positioned
correctly.
Also make sure that the condensation tank is inserted
correctly, otherwise the device cannot be switched back
on.
Activities required after maintenance
If you want to continue using the device:
•
Leave the device to rest for 12 to 24 hours, so the
refrigerant can accumulate within the compressor. Wait
12 to 24 hours before switching the device back on! Acting
contrary might lead to compressor damage and a
malfunctioning device. If so, any warranty claims will be
voided.
•
Reconnect the device to the mains.
If you do not intend to use the device for a considerable time:
•
Store the device according to the Storage chapter.