dehumidifier TTK 70 HEPA

Intended use

Only use the device for drying and dehumidifying room air, while
adhering to and following the technical data.
In addition, the device may also be used as a kind of clothes
dryer to dry wet laundry.
Intended use comprises:

• dehumidifying and drying:

– living rooms, bedrooms and basements
– holiday homes, camper vans

• maintaining the dryness of:

– storage spaces, archives, laboratories, garages
– changing rooms etc.

Foreseeable misuse

The device is not intended for industrial use.

• Do not place the device on wet or flooded ground.
• Do not place any objects, e.g. clothing, on the device.
• Do not use the device out of doors.
• Do not make any unauthorised modifications, alterations or

structural changes to the device.

• Any use other than the intended use is regarded as a

reasonably foreseeable misuse.

Personnel qualifications

People who use this device must:

• be aware of the dangers that occur when working with

electric devices in damp areas.

• have read and understood the operating manual, especially

the Safety chapter.

Maintenance tasks which require the housing to be opened
must only be carried out by specialist companies for cooling and
air-conditioning or by Trotec.

Safety signs and labels on the device

Note

Do not remove any safety signs, stickers or labels from
the device. Keep all safety signs, stickers and labels in
legible condition.

The following safety signs and labels are attached to the device:

TTK 70 HEPA

Follow the manual

This symbol indicates that the operating manual must
be observed.

Follow the repair manual

Disposal, maintenance and repair work of the
refrigerant circuit may only be carried out in
accordance with the manufacturer's specifications and
by persons having a certificate of qualification. A
corresponding repair manual is available from the
manufacturer upon request.

Residual risks

Danger
Natural refrigerant propane (R290)!

H220 – Extremely flammable gas.
H280 – Contains gas under pressure; may explode if
heated.

P210 – Keep away from heat, sparks, open flames and
other ignition sources. No smoking.
P377 – Leaking gas fire: Do not extinguish, unless leak
can be stopped safely.
P410+P403 – Protect from sunlight. Store in a well-
ventilated place.

Warning of electrical voltage

Work on the electrical components must only be
carried out by an authorised specialist company!

Содержание TTK 70 HEPA

Страница 1: ...TRT BA TTK70HEPA TC211001TTRT09 001 EN TTK 70 HEPA EN OPERATING MANUAL DEHUMIDIFIER...

Страница 2: ...y before starting or using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the war...

Страница 3: ...device in rooms where potentially leaking refrigerant cannot accumulate Only position the device in rooms where there is no source of ignition e g open flames an active gas appliance or an electric he...

Страница 4: ...which require the housing to be opened must only be carried out by specialist companies for cooling and air conditioning or by Trotec Safety signs and labels on the device Note Do not remove any safe...

Страница 5: ...through the air inlet the air filter the HEPA filter the evaporator and to the condenser located behind it The air is cooled at the cold evaporator until it is below the dew point Water vapour contain...

Страница 6: ...s to be transported together can be gathered from the applicable transport regulations To make the device easier to transport it is fitted with a carry handle Before transporting the device observe th...

Страница 7: ...r cable is not damaged and that you do not damage it during unwinding Start up When positioning the device observe the minimum distance from walls or other objects as described in the chapter Technica...

Страница 8: ...ion mode even after the set nominal value has been reached until the device is switched off 25 18 12 15 13 14 26 19 30 28 11 27 16 17 20 21 22 23 29 24 Operating elements No Designation Meaning 11 LED...

Страница 9: ...e flashes 2 Repeatedly press the MODE button 12 until the operating mode LED Dehumidification 30 flashes The LED of the selected operating mode flashes for approx 5 seconds before the operating mode i...

Страница 10: ...n set it will not be saved The device memorises the settings even during short power failures In this case the device automatically switches back on The previous settings are saved except for the time...

Страница 11: ...dry In addition the device may also be used as a kind of clothes dryer to dry wet laundry in living or working spaces When positioning the device or a clothes horse please observe the minimum distance...

Страница 12: ...nsure that the relative room humidity complies with the technical data Check the preselected desired room humidity level The relative humidity in the room must be above the selected range If necessary...

Страница 13: ...nd or drain hose X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign objects and...

Страница 14: ...entire refrigerant circuit is a maintenance free hermetically sealed system and may only be maintained or repaired by specialist companies for cooling and air conditioning or by Trotec Safety signs a...

Страница 15: ...Errors and faults Make sure that the HEPA filter is installed before switching the device on The operating life is approx 1 year depending on the degree of air pollution If required visually inspect...

Страница 16: ...er located in the air inlet cover The filter has to be cleaned as soon as it is dirty It becomes clear that it is contaminated if the device s performance is reduced see chapter Errors and faults 1 Re...

Страница 17: ...k over a suitable drain e g a toilet a wash basin or a sink 3 Rinse the tank with clear water Clean the tank regularly using a mild cleaning agent no detergent 4 Refit the condensation tank into the d...

Страница 18: ...r Technical annex Technical data Parameter Value Model TTK 70 HEPA Max dehumidification performance 24 l 24 h Dehumidification performance 30 C and 80 RH 20 l 24 h Air flow rate 140 m3 h Operating ran...

Страница 19: ...EN 19 dehumidifier TTK 70 HEPA Circuit diagram...

Страница 20: ...3 Electrical Box 26 Handle 2 Guided Light 14 Fixed Mount R 27 Tank Cover 3 Front Shell 15 Main PCB 28 Foam 4 Handle R 16 Electrical Cover 29 Water Tank 5 Wind Wheel 17 Handle L 30 Water Level Mark 6 C...

Страница 21: ...or many EU countries on the website https hub trotec com id 45090 Otherwise please contact an official recycling centre for electronic and electrical equipment authorised for your country The separate...

Страница 22: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Отзывы: