background image

5

EN

Operating manual – dehumidifier TTK 54 E / TTK 66 E

Transport and storage

Notice

If you store or transport the device improperly, the
device may be damaged.
Note the information regarding transport and storage of
the device.

Transport

Before

 transporting the device, proceed as follows:

Switch off the device.

Hold onto the mains plug while pulling the power cable out
of the mains socket.

Drain the remaining condensate from the device and the
condensation drain hose (see chapter Maintenance).

To make the device easier to transport, it is fitted with
wheels.

Do not use the power cable to drag the device.

Only wheel the device on a level and smooth surface.

After

 transporting the device, observe the following:

Set up the device in an upright position after transport.

Leave the device to rest for 12 - 24 hours, so the
refrigerant can accumulate within the compressor. Wait
12 - 24 hours before switching the device back on! Acting
contrary might lead to compressor damage and a
malfunctioning device. If so, any warranty claims will be
voided.

Storage

Before

 storing the device, proceed as follows:

Drain the remaining condensate from the device and the
condensation drain hose (see chapter Maintenance).

Empty and clean the condensation tank prior to storage.

When the device is not being used, observe the following
storage conditions:

dry and protected from frost and heat

in an upright position where it is protected from dust and
direct sunlight

with a cover to protect it from invasive dust if necessary

Place no further devices or objects on top of the device to
prevent it from being damaged.

Assembly and installation

Scope of delivery

1 x device

1 x condensation drain hose, length: 0.6 m,
diameter: 14 mm

1 x air filter

1 x manual

Unpacking the device

1. Open the cardboard box and take the device out.
2. Completely remove the packaging.
3. Fully unwind the power cable. Make sure that the power

cable is not damaged and that you do not damage it during
unwinding.

Start-up

When positioning the device, observe the minimum distance
from walls or other objects as described in chapter Technical
Data.

A

B

C

C

D

Содержание TTK 54 E

Страница 1: ...TRT BA TTK54E TTK66E TC 001 EN TTK 54 E TTK 66 E EN OPERATING MANUAL DEHUMIDIFIER...

Страница 2: ...nd safely Follow the manual Information marked with this symbol indicates that the operating manual must be observed You can download the current version of the operating manual and the EU declaration...

Страница 3: ...may result in electric shock fire and or serious injury Save all warnings and instructions for future reference This appliance can be used by children aged from 8 years and above and persons with red...

Страница 4: ...g clothing on the device Do not use the device outdoors Any unauthorised modifications alterations or structural changes to the device are forbidden Any operation other than as described in this manu...

Страница 5: ...nly during the defrost phase through the integrated drain nozzle into the condensation tank below It is fitted with a float to measure the filling level The device has a control panel for operating an...

Страница 6: ...mpressor damage and a malfunctioning device If so any warranty claims will be voided Storage Before storing the device proceed as follows Drain the remaining condensate from the device and the condens...

Страница 7: ...ons Inserting the air filter Notice Do not operate the device without an inserted air filter Without the air filter the inside of the device will be heavily contaminated This could reduce the performa...

Страница 8: ...time a setting is activated Setting the operating mode Setting the desired relative room humidity You can only change the relative room humidity in dehumidification mode 1 Press the plus minus button...

Страница 9: ...ed on the segment display 22 the timer is also deactivated A full condensation tank can cause the device to be switched off before the set number of hours until automatic switch off have elapsed Laund...

Страница 10: ...can vary Do not switch off the device during automatic defrost Do not remove the mains plug from the mains socket Drying laundry In addition the device may also be used as a kind of clothes dryer to d...

Страница 11: ...e In this case the compressor switches off automatically once the relative room humidity is below 45 From the outside check the condenser for dirt see chapter Maintenance If the condenser is dirty hav...

Страница 12: ...Fault at humidity sensor Disconnect the device briefly from the mains Should the error still be displayed after the restart please contact the customer service ES Fault at temperature sensor E3 Genera...

Страница 13: ...achment screws X X Test run X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Empty condensation tank and drain hose Check the a...

Страница 14: ...eck the inside of the device for dirt 4 If you see a thick layer of dust have the inside of the device cleaned by a specialist company for cooling and air conditioning or by Trotec 5 Put the air filte...

Страница 15: ...densation tank into the device Make sure not to damage the float when inserting or removing the condensation tank In doing so make sure that the float is positioned correctly In doing so make sure tha...

Страница 16: ...1430 1430 CO2 equivalent 0 15 t 0 17 t Condensation tank capacity 3 l 3 l Sound pressure level 1 m distance 48 dB A 48 dB A Dimensions length x width x height 245 x 350 x 510 mm 245 x 350 x 510 mm Mi...

Страница 17: ...y 8 Fixed speed reciprocating compressor 1 3 Handle for Tank 3 2 3 9 Parts of compressor return pipe 2 Front panel assembly 3 2 4 Electrical Control Box 10 Capillary Assembly 2 1 Front Panel 4 Parts o...

Страница 18: ...mpressor return pipe 1 3 Handle for Tank 3 2 3 10 Capillary Assembly 2 Front panel assembly 3 2 4 Electrical Control Box 11 Condenser Assembly 2 1 Front Panel 4 Parts of middle clapboard 12 Evaporator...

Страница 19: ...ec24 com The separate collection of waste electrical and electronic equipment aims to enable the re use recycling and other forms of recovery of waste equipment as well as to prevent negative effects...

Страница 20: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Отзывы: