Trotec TTK 500 Скачать руководство пользователя страница 3

EN

3

dehumidifier TTK 500

Do not cover the device during operation.

Do not sit on the device.

This appliance is not a toy. Keep away from children and
animals.

Occasionally observe the device during operation.

Check accessories and connection parts for possible
damage prior to every use of the device. Do not use any
defective devices or device parts.

Ensure that all electric cables outside of the device are
protected from damage (e.g. caused by animals). Never
use the device if electric cables or the power connection
are damaged!

The mains connection must correspond to the
specifications in the Technical annex.

Insert the mains plug into a properly fused mains socket.

Observe the device's power input, cable length and
intended use when selecting extensions to the power
cable. Completely unroll extension cables. Avoid electrical
overload.

Do not under any circumstances use the device if you
detect damages on the mains plug or power cable. 
If the power cable is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
Defective power cables pose a serious health risk!

Before carrying out maintenance, care or repair work on
the device, remove the mains plug from the mains socket.
Hold onto the mains plug while doing so.

Switch the device off and disconnect the power cable from
the mains socket when the device is not in use.

When positioning the device, observe the minimum
distances from walls and other objects as well as the
storage and operating conditions specified in the Technical
annex.

Make sure that the air inlet and outlet are not obstructed.

Make sure that the suction side is kept free of dirt and
loose objects.

Never insert any objects or limbs into the device.

Do not remove any safety signs, stickers or labels from the
device. Keep all safety signs, stickers and labels in legible
condition.

Only transport the device in an upright position with an
emptied condensation tank or drain hose.

Discharge the collected condensate before transport and
storage. Do not drink it. Health hazard!

Only use original spare parts, for otherwise safe and
functional operation cannot be ensured.

Safety warnings for devices containing flammable
refrigerants

Only position the device in rooms where potentially leaking
refrigerant cannot accumulate. Unventilated rooms, in
which the device is installed, operated or stored, must be
built in a way to ensure that potentially leaking refrigerant
cannot accumulate. This serves to avoid fire or explosion
hazards resulting from an ignition of the refrigerant by an
electric furnace, cooking stove or another ignition source.

Only position the device in rooms where there is no source
of ignition (e.g. open flames, an active gas appliance or an
electric heater).

Please note that the refrigerant is odourless.

Only install the device in compliance with the national
installation regulations.

Please observe the local regulations.

Observe the national gas regulations.

Only install, operate and store the device in a room
measuring more than 4 m

2

.

Store the device in a way that no mechanical damage can
occur.

Please note that the connected pipelines must not contain
any sources of ignition.

R454C comes with a low GWP factor (Global Warning
Potential) of 146 and an ODP (ozone depletion potential)
of 0.

Observe the maximum refrigerant capacity in the technical
data.

Do not drill through or burn.

Do not use any means other than those recommended by
the manufacturer for accelerating the defrosting process.

Every person working with or at the refrigerant circuit must
be able to provide a certificate of qualification issued by a
body accredited by the industry, demonstrating their
competence in the safe use of refrigerants based on a
procedure well-known in the industry.

Service work may only be carried out in accordance with
the manufacturer's specifications. If maintenance and
repair work require the support of additional persons, the
person trained in handling flammable refrigerants shall
continuously supervise the work carried out.

The entire refrigerant circuit is a maintenance-free,
hermetically sealed system and may only be maintained or
repaired by specialist companies for cooling and 
air-conditioning or by Trotec.

Содержание TTK 500

Страница 1: ...TRT BA TTK500 TC220617TTRT04 005 EN TTK 500 EN ORIGINAL INSTRUCTIONS DEHUMIDIFIER...

Страница 2: ...iate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious in...

Страница 3: ...transport and storage Do not drink it Health hazard Only use original spare parts for otherwise safe and functional operation cannot be ensured Safety warnings for devices containing flammable refrig...

Страница 4: ...chapter Maintenance tasks which require the housing to be opened must only be carried out by specialist companies for cooling and air conditioning or by Trotec Safety signs and labels on the device N...

Страница 5: ...nsation to automatically dehumidify rooms The fan sucks damp room air through the air inlet the air filter the evaporator and to the condenser located behind it The air is cooled at the cold evaporato...

Страница 6: ...ent s arrangement and the maximum number of components to be transported together can be gathered from the applicable transport regulations To make the device easier to transport it is fitted with a t...

Страница 7: ...he device out 2 Completely remove the packaging 3 Fully unwind the power cable Make sure that the power cable is not damaged and that you do not damage it during unwinding Start up When positioning th...

Страница 8: ...14 2 Remove the screw 13 TTK 500 13 14 15 3 Turn the transport handle by 90 TTK 500 14 13 4 Insert the screw 13 in the rivet 15 5 Tighten the screws 13 14 Inserting the air filter Note Do not operate...

Страница 9: ...ation drain hose as follows Place a sufficiently dimensioned container at least 90 litres beside the device and insert the hose end Check the filling level of the container regularly TTK 500 Position...

Страница 10: ...10 EN dehumidifier TTK 500 Installing the condensate pump optional 1 TTK 500 2 TT K 50 0 3 TTK 500 4 TT K 50 0 5 TTK 500 6 TTK 500...

Страница 11: ...s and energy consumption 16 OFF position Device switched off 17 ON position Device switched on 18 Hygrostat connection Connection for hygrostat operation optional Warning of electrical voltage Risk of...

Страница 12: ...tic defrost Dehumidification is briefly interrupted during defrosting The fan keeps running The duration of the defrost process can vary Do not switch off the device during automatic defrost Do not re...

Страница 13: ...ir filter From the outside check the condenser for dirt see chapter Maintenance If the condenser is dirty have it cleaned by a specialist company or by Trotec The device is loud or vibrates Check whet...

Страница 14: ...ews X X Test run X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Empty the condensate pump condensation tank and construction...

Страница 15: ...gns and labels attached to the device at regular intervals Replace illegible safety signs Cleaning the housing Clean the housing with a soft damp and lint free cloth Make sure that no moisture enters...

Страница 16: ...by ejected compressed air upon activation of the compressed air supply Hold the compressed air hose away from your body Pointing the compressed air hose at another person is prohibited Note If require...

Страница 17: ...rrying handle 2 off the base frame and the cooling system TTK 500 1 2 7 Carefully set the housing aside 8 Clean the interior of the device by means of compressed air 9 Reassemble the housing on base f...

Страница 18: ...0 MPa 3 0 MPa Pressure suction side 0 6 MPa 0 6 MPa Pressure outlet side 2 2 MPa 2 2 MPa Nominal voltage 220 240 V 50 Hz 110 230 V 50 Hz Max power consumption 1593 W 1593 W Nominal current 7 3 A 14 7...

Страница 19: ...EN 19 dehumidifier TTK 500 Wiring diagram With operating hours counter...

Страница 20: ...20 EN dehumidifier TTK 500 With operating hours counter and MID counter...

Страница 21: ...instructions ITEM NO SPARE PART QTY ITEM NO SPARE PART QTY H1 Top panel 1 H10 Latch 4 H2 Left panel 1 H11 Foam sheet 1 H3 Right panel 1 H12 Round insert 2 H4 Front panel 1 H13 Saddle spacer 4 H5 Rear...

Страница 22: ...lamp 1 B2 Compressor 1 B14 Wheel 2 B3 Overload protection switch 1 B15 Starlock washer with cap 2 B4 Grommet 3 B16 Tubular foot 1 B5 Pin spacer 3 B17 Saddle foot 2 B6 Compressor screw 3 B18 Round inse...

Страница 23: ...TY ITEM NO SPARE PART QTY C1 Cooling system baseplate 1 C9 Fan blade 1 C2 Ventilation duct 1 C10 Fan motor support 1 C3 Heat exchanger 1 C11 Side panel spacer 2 C4 Heat exchanger insulation EPS 1 C12...

Страница 24: ...ns of the components mentioned in these instructions ITEM NO SPARE PART QTY ITEM NO SPARE PART QTY D1 Control s box 1 D6 Control box internal wiring 1 D2 Control s cover 1 D7 Unit internal wiring 1 D3...

Страница 25: ...refrigerant appropriately and according to the national regulations Declaration of conformity Declaration of conformity in accordance with the EC Machinery Directive 2006 42 EC Annex II Part 1 Section...

Страница 26: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Отзывы: