Trotec TTK 500 Скачать руководство пользователя страница 25

EN

25

dehumidifier TTK 500

Disposal

Always dispose of packing materials in an environmentally
friendly manner and in accordance with the applicable local
disposal regulations.

The icon with the crossed-out waste bin on waste

electrical or electronic equipment is taken from Directive
2012/19/EU. It states that this device must not be disposed of
with the household waste at the end of its life. You will find
collection points for free return of waste electrical and electronic
equipment in your vicinity. The addresses can be obtained from
your municipality or local administration. You can also find out
about other return options that apply for many EU countries on
the website https://hub.trotec.com/?id=45090. Otherwise,
please contact an official recycling centre for electronic and
electrical equipment authorised for your country.
The separate collection of waste electrical and electronic
equipment aims to enable the re-use, recycling and other forms
of recovery of waste equipment as well as to prevent negative
effects for the environment and human health caused by the
disposal of hazardous substances potentially contained in the
equipment.
The device is operated with fluorinated greenhouse gas, which
can be dangerous for the environment and contribute to global
warming when emitted to the atmosphere.
Further information is provided on the nameplate.
Dispose of the refrigerant appropriately and according to the
national regulations.

Declaration of conformity

Declaration of conformity in accordance with the EC Machinery
Directive 2006/42/EC, Annex II, Part 1, Section A

We – Trotec GmbH – declare in sole responsibility that the
product designated below was developed, constructed and
produced in compliance with the requirements of the
EC Machinery Directive in the version 2006/42/EC.

Product model / Product:

TTK 500

Product type:

dehumidifier

Year of manufacture as of:

2022

Relevant EU directives:

2011/65/EU

2012/19/EU

2014/30/EU

2015/863/EU

Applied harmonised standards:

EN 60335-1:2012

EN 60335-1:2012/A15:2021

EN 60335-2-40:2003

EN 60335-2-40:2003/A1:2006

EN 60335-2-40:2003/A2:2009

EN 60335-2-40:2003/A11:2004

EN 60335-2-40:2003/A12:2005

EN 60335-2-40:2003/A13:2012

EN 60335-2-40:2003/AC:2006

EN 60335-2-40:2003/AC:2010

EN 60335-2-40:2003/AC:2013

Applied national standards and technical specifications:

EN IEC 55014-1:2021

EN IEC 55014-2:2021

IEC 60335-2-40:2018

EN IEC 61000-3-2:2019

EN IEC 61000-3-2:2019/A1:2021

EN 60335-1:2012/A1:2019

EN 60335-1:2012/A2:2019

EN 60335-1:2012/A14:2019

EN 61000-3-3:2013/A1:2019

IEC 60335-1:2010

IEC 60335-1:2010/A1:2013/A2:2016

IEC 61000-3-2:2018

IEC 61000-3-2:2018/A1:2020

IEC 61000-3-3:2013

IEC 61000-3-3:2013/A1:2017

IEC 61000-3-3:2013/A2:2021

Manufacturer and name of the authorised representative of
the technical documentation:

Trotec GmbH
Grebbener Straße 7, D-52525 Heinsberg
Phone: +49 2452 962-400
E-mail: [email protected]

Place and date of issue:
Heinsberg, 

01.06.2022

Joachim Ludwig, Managing Director

Содержание TTK 500

Страница 1: ...TRT BA TTK500 TC220617TTRT04 005 EN TTK 500 EN ORIGINAL INSTRUCTIONS DEHUMIDIFIER...

Страница 2: ...iate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious in...

Страница 3: ...transport and storage Do not drink it Health hazard Only use original spare parts for otherwise safe and functional operation cannot be ensured Safety warnings for devices containing flammable refrig...

Страница 4: ...chapter Maintenance tasks which require the housing to be opened must only be carried out by specialist companies for cooling and air conditioning or by Trotec Safety signs and labels on the device N...

Страница 5: ...nsation to automatically dehumidify rooms The fan sucks damp room air through the air inlet the air filter the evaporator and to the condenser located behind it The air is cooled at the cold evaporato...

Страница 6: ...ent s arrangement and the maximum number of components to be transported together can be gathered from the applicable transport regulations To make the device easier to transport it is fitted with a t...

Страница 7: ...he device out 2 Completely remove the packaging 3 Fully unwind the power cable Make sure that the power cable is not damaged and that you do not damage it during unwinding Start up When positioning th...

Страница 8: ...14 2 Remove the screw 13 TTK 500 13 14 15 3 Turn the transport handle by 90 TTK 500 14 13 4 Insert the screw 13 in the rivet 15 5 Tighten the screws 13 14 Inserting the air filter Note Do not operate...

Страница 9: ...ation drain hose as follows Place a sufficiently dimensioned container at least 90 litres beside the device and insert the hose end Check the filling level of the container regularly TTK 500 Position...

Страница 10: ...10 EN dehumidifier TTK 500 Installing the condensate pump optional 1 TTK 500 2 TT K 50 0 3 TTK 500 4 TT K 50 0 5 TTK 500 6 TTK 500...

Страница 11: ...s and energy consumption 16 OFF position Device switched off 17 ON position Device switched on 18 Hygrostat connection Connection for hygrostat operation optional Warning of electrical voltage Risk of...

Страница 12: ...tic defrost Dehumidification is briefly interrupted during defrosting The fan keeps running The duration of the defrost process can vary Do not switch off the device during automatic defrost Do not re...

Страница 13: ...ir filter From the outside check the condenser for dirt see chapter Maintenance If the condenser is dirty have it cleaned by a specialist company or by Trotec The device is loud or vibrates Check whet...

Страница 14: ...ews X X Test run X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Empty the condensate pump condensation tank and construction...

Страница 15: ...gns and labels attached to the device at regular intervals Replace illegible safety signs Cleaning the housing Clean the housing with a soft damp and lint free cloth Make sure that no moisture enters...

Страница 16: ...by ejected compressed air upon activation of the compressed air supply Hold the compressed air hose away from your body Pointing the compressed air hose at another person is prohibited Note If require...

Страница 17: ...rrying handle 2 off the base frame and the cooling system TTK 500 1 2 7 Carefully set the housing aside 8 Clean the interior of the device by means of compressed air 9 Reassemble the housing on base f...

Страница 18: ...0 MPa 3 0 MPa Pressure suction side 0 6 MPa 0 6 MPa Pressure outlet side 2 2 MPa 2 2 MPa Nominal voltage 220 240 V 50 Hz 110 230 V 50 Hz Max power consumption 1593 W 1593 W Nominal current 7 3 A 14 7...

Страница 19: ...EN 19 dehumidifier TTK 500 Wiring diagram With operating hours counter...

Страница 20: ...20 EN dehumidifier TTK 500 With operating hours counter and MID counter...

Страница 21: ...instructions ITEM NO SPARE PART QTY ITEM NO SPARE PART QTY H1 Top panel 1 H10 Latch 4 H2 Left panel 1 H11 Foam sheet 1 H3 Right panel 1 H12 Round insert 2 H4 Front panel 1 H13 Saddle spacer 4 H5 Rear...

Страница 22: ...lamp 1 B2 Compressor 1 B14 Wheel 2 B3 Overload protection switch 1 B15 Starlock washer with cap 2 B4 Grommet 3 B16 Tubular foot 1 B5 Pin spacer 3 B17 Saddle foot 2 B6 Compressor screw 3 B18 Round inse...

Страница 23: ...TY ITEM NO SPARE PART QTY C1 Cooling system baseplate 1 C9 Fan blade 1 C2 Ventilation duct 1 C10 Fan motor support 1 C3 Heat exchanger 1 C11 Side panel spacer 2 C4 Heat exchanger insulation EPS 1 C12...

Страница 24: ...ns of the components mentioned in these instructions ITEM NO SPARE PART QTY ITEM NO SPARE PART QTY D1 Control s box 1 D6 Control box internal wiring 1 D2 Control s cover 1 D7 Unit internal wiring 1 D3...

Страница 25: ...refrigerant appropriately and according to the national regulations Declaration of conformity Declaration of conformity in accordance with the EC Machinery Directive 2006 42 EC Annex II Part 1 Section...

Страница 26: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Отзывы: