Declaration of conformity

The text below sets out the contents of the declaration of
conformity. The signed declaration of conformity can be found
at 

https://hub.trotec.com/?id=42377

.

Declaration of conformity

In accordance with the EC Machinery Directive 2006/42/EC, Annex II, part 1,

Section A

Herewith, we – Trotec GmbH & Co. KG – declare that the
machinery designated below was developed, constructed and
produced in compliance with the requirements of the
EC Machinery Directive in the version 2006/42/EC.

Product model / Product:

TTK 171 ECO

Product type:

dehumidifier

Year of manufacture as of:

2018

Relevant EU directives:

Applied harmonised standards:

EN ISO 12100:2010

EN 55014-2:2015

EN 55014-1:2017

EN 60335-1:2012/A11:2014

EN 60335-2-40:2003/A13:2012

EN 61000-3-2:2014

EN 61000-3-3:2013

EN 62233:2008

Applied national standards and technical specifications:

AfPS GS 2014:01 PAK

Manufacturer and name of the authorised representative of
the technical documentation:

Trotec GmbH & Co. KG
Grebbener Straße 7, D-52525 Heinsberg
Phone: +49 2452 962-400
E-mail: [email protected]

Place and date of issue:
Heinsberg, 

12.01.2018

Detlef von der Lieck, Managing Director

Содержание TTK 171 ECO

Страница 1: ...TRT BA TTK171ECO TC2014 18 003 EN TTK 171 ECO EN ORIGINAL INSTRUCTIONS DEHUMIDIFIER...

Страница 2: ...sing the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions...

Страница 3: ...uction side is kept free of dirt and loose objects Do not remove any safety signs stickers or labels from the device Keep all safety signs stickers and labels in legible condition Only transport the d...

Страница 4: ...ator until it is below the dew point Water vapour contained in the room air precipitates on the evaporator fins as condensation or rime The dehumidified cooled air is slightly warmed at the condenser...

Страница 5: ...5 11 10 6 8 9 7 No Designation 1 Transport handle 2 Operating element 3 Recessed handle 4 Transport wheel 5 Feed through for condensation drain hose 6 Air outlet 7 Condensation tank 8 Venting slots 9...

Страница 6: ...ore switching the device back on Acting contrary might lead to compressor damage and a malfunctioning device If so any warranty claims will be voided Storage Before storing the device observe the foll...

Страница 7: ...s and the axle must be attached to the device To do so please proceed as follows The device is placed on its front side 1 Place a washer 12 on the axle 13 2 Place a wheel 4 in front of the washer 3 Pl...

Страница 8: ...ng the device check the condition of the power cable If there are doubts as to the sound condition contact the customer service Set the device up in an upright and stable position Do not create trippi...

Страница 9: ...the device will be heavily contaminated This could reduce the performance and result in damage to the device Make sure that the air filter is installed before switching the device on Inserting the con...

Страница 10: ...witch on timer function For enabling or disabling the automatic switch off timer function 21 On Off button For switching the device on or off No Designation Meaning 22 Timer LED Illuminated when the t...

Страница 11: ...automatic switch on upon expiry of a preset number of hours automatic switch off upon expiry of a preset number of hours The function can be set in all operating modes and also during stand by The nu...

Страница 12: ...switch on If the device is disconnected from the power supply all settings for automatic switch on are deleted Manually switching the device on disables the automatic switch on function If you select...

Страница 13: ...vice is running but there is no formation of condensate Check whether the condensation drain hose is positioned correctly Check the float in the condensation tank for dirt If necessary clean the conde...

Страница 14: ...de of the device is dirty have it cleaned by a specialist company for cooling and air conditioning or by Trotec Note Wait for at least 3 minutes after maintenance and repair work Only then switch the...

Страница 15: ...t least annually Check air inlets and outlets for dirt and foreign objects and clean if necessary X X Clean the exterior X X Visually check the inside of the device for dirt X X Check the air filter f...

Страница 16: ...irt Check the air filter for dirt and foreign objects and clean or replace if necessary Replace the air filter Check for damage Check the attachment screws Test run Empty the condensation tank and dra...

Страница 17: ...side of the device for dirt 4 If you see a thick layer of dust have the inside of the device cleaned by a specialist company for cooling and air conditioning or by Trotec 5 Put the air filter back in...

Страница 18: ...float when inserting or removing the condensation tank In doing so make sure that the float is positioned correctly Also make sure that the condensation tank is inserted correctly otherwise the devic...

Страница 19: ...ulates that this equipment must not be disposed of with the household waste at the end of its life You will find collection points for free return of waste electrical and electronic equipment in your...

Страница 20: ...inery Directive in the version 2006 42 EC Product model Product TTK 171 ECO Product type dehumidifier Year of manufacture as of 2018 Relevant EU directives Applied harmonised standards EN ISO 12100 20...

Страница 21: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Отзывы: