EN
13
dehumidifier TTK 171 ECO
Available accessories
Warning
Only use accessories and additional equipment
specified in the instructions.
Using insertion tools or accessories other than those
specified in the instructions may cause a risk of injury.
Designation
Article number
Air filter (filter fleece)
7.710.000.826
External condensate pump
6.100.003.020
Hose adapter TTK 171 ECO
7.331.001.160
Air transport hose
6.100.001.120
Errors and faults
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
The device does not start:
•
Check the power connection.
•
Check the power cable and mains plug for damages.
•
Check the on-site fusing.
•
Check the filling level of the condensation tank and empty
it if necessary. The LEDs
Tank Full
(15) and
Full
(25) must
not light up.
•
Check the condensation tank for correct seating.
•
Check the room temperature. Observe the device's
permissible operating range according to the technical
data.
•
Wait for 10 minutes before restarting the device. If the
device is not starting, have the electrics checked by a
specialist company or by Trotec.
The device is running, but there is no formation of
condensate:
•
Check whether the condensation drain hose is positioned
correctly.
•
Check the float in the condensation tank for dirt.
If necessary, clean the condensation tank. The float must
be able to move freely.
•
Check the room temperature. Observe the device's
permissible operating range according to the technical
data.
•
Ensure that the relative room humidity complies with the
technical data.
•
Check the air filter for dirt. If necessary, clean or replace
the air filter.
•
From the outside, check the condenser for dirt (see
chapter Maintenance). If the condenser is dirty, have it
cleaned by a specialist company or by Trotec.
•
When using the condensate pump: Check the
condensation tank and hoses for dirt.
The device is loud or vibrates:
•
Check whether the device is set up in a stable and upright
position.
Condensate is leaking:
•
Check the device for leaks.
The compressor does not start:
•
Check the room temperature. Observe the device's
permissible operating range according to the technical
data.
•
Ensure that the relative room humidity complies with the
technical data.
•
Check whether the overheating protection of the
compressor has tripped. Disconnect the device from the
mains and let it cool down for approx. 10 minutes before
reconnecting it.
•
The device might carry out an automatic defrost. During
automatic defrost, the device does not dehumidify.