Operating Manual – Dehumidifier TTK 1500

EN

Overview and list of spare parts

Main components

Note!

The position numbers of the spare parts differ from those 
describing the positions of other parts mentioned in this 
operating manual.

No.

Item number

Spare part

No.

Item number

Spare part

1

SD062150

electric box lid

30

SD086951

TEV INE-3-GA

2

SD071750

outlet grille

31

SP066350

Schrader valve

3

SA205501

console assembly

32

SD071650

duct flange

4

SA582501

electric box assembly

33

SD086350

support bkt

6

7150001210

fan assembly (drilled)

34

SD080650

component box ABS drilled

7

7161000283

compressor

35

SD300550

pump bracket

8

7310000886

drip tray

36

SD149650

receiver/drier

9

SD141553

evaporator

37

7140000899

operating hours counter (panel mount)

10

SD289750

frame (left side)

38

SD097250

evaporator spacer

11

SD289751

frame (right side)

40

SD266450

HP switch ACB-DB88 400 psi

12

SD291850

crash bar

41

SD266550

LP switch LCB-DA15 7 psi

13

SD289850

axle

42

SD188950

rocker switch 1 pole c/o

14

7600000080

wheel

44

SD085150

duct flange top and bottom

15

SD288750

support bracket

45

SD085250

duct flange side

16

SD290150

bracket

46

SD085251

duct flange side

17

SD288850

blanking panel

47

SD175750

filter bracket

18

SD289550

saddle washer

48

SD175850

filter bracket

19

SD520851

spacer mounting tube 42 mm long

49

7710000911

filter washable

20

SD011450

side panel

50

SD166250

solenoid valve 3/8

21

SD232150

isolator switch

51

SD166550

solenoid coil 230 V, 50 Hz

22

7242000887

mains in box

54

SP152150

M20 plastic gland back nut

24

7130000912

float switch (62-00-554)

56

7310000349

tube insert (62-00-094)

25

7170000191

peristaltic pump 11 litre per hr.

57

SD062350

humidistat

27

SD294650

bulkhead connector

58

SD041450

control knob

28

7310000348

locking collet

60

SD293050

damper plate

Содержание TTK 1500

Страница 1: ...TTK 1500 OPERATING MANUAL DEHUMIDIFIER EN TRT BA TTK1500 TC 001 EN...

Страница 2: ......

Страница 3: ...tronically processing duplicating or spreading the publication Subject to technical changes All rights reserved Trademarks are used without guarantee that they may be used freely and primarily followi...

Страница 4: ...e and the relative humidity the condensed water either drops continuously or only during the defrost phase into the condensation tray The condensation is fed through a pressure resistant pipe connecti...

Страница 5: ...ues Model TTK 1500 Dehumidifying capacity max 400 l 24 h Dehumidifying capacity 20 C 60 relative humidity 100 l 24 h Suitable for room dimensions up to construction drying or clearing water damages ma...

Страница 6: ...WITCH CYCLE FAULT LAMP FAN MOTOR FAN CAP DELAY TIMER CONTACTOR COMPRESSOR CONDENSATE PUMP PUMP FUSE HUMIDISTAT FLOAT SWITCH RELAY No 1 ISOLATOR RELAY No 2 HIGH LEVEL PUMP RUN FLOAT SWITCH L1 L3 L2 HOU...

Страница 7: ...ying and dehumidifying room air while adhering to and following the technical data Intended use encapsulates drying and dehumidifying production plants underground rooms store rooms archives laborator...

Страница 8: ...ift or an elevating truck Before transporting the device proceed as follows 1 Switch off the device at the mains switch see chapter Operating elements 2 Remove the mains plug from the mains socket Do...

Страница 9: ...sing a generator ensure that the generator supplies at least 4 kW of power device starting current can exceed the nominal current by four or five times Also note this fact when using several devices a...

Страница 10: ...ain hose is properly connected to the device and is free of damage 2 Depending on use position the end of the condensation drain hose as follows Position a sufficiently large container at least 90 lit...

Страница 11: ...tion mode optional The device can also be operated with a humidistat The humidistat switches the device on or off depending on the humidity If you choose to operate the device with an optional humidis...

Страница 12: ...positioned correctly Check that the condensation pump functions properly Check for abnormal vibrations and sounds Remove external dirt Check the room temperature Check the device s permissible workin...

Страница 13: ...f necessary X X replace air filter X check for damages X check attachment screws X X carry out a test run X Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 check air inlets and ou...

Страница 14: ...alist companies for cooling and air conditioning or by Trotec Visual check for dirt in the inside of the device 1 Remove the air filter see chapter Cleaning the air inlets and the air filter 2 Shine a...

Страница 15: ...e corners and edges must not be rounded or misshaped Before reinserting the air filter ensure that it is dry and is not damaged Read the chapter Maintenance intervals and replace the air filter punctu...

Страница 16: ...vaporator spacer 11 SD289751 frame right side 40 SD266450 HP switch ACB DB88 400 psi 12 SD291850 crash bar 41 SD266550 LP switch LCB DA15 7 psi 13 SD289850 axle 42 SD188950 rocker switch 1 pole c o 14...

Страница 17: ...8 29 12 29 12 28 1 1 6 1 6 F3A 15 14 16 17 1 3 5 13 14 6 4 2 A1 A2 Note The position numbers of the spare parts differ from those describing the positions of other parts mentioned in this operating ma...

Страница 18: ...e parts differ from those describing the positions of other parts mentioned in this operating manual No Item number Spare part 1 7310001153 console moulding 2 7141000891 pilot light red rectangular 25...

Страница 19: ...ata Dispose of the refrigerant oil mixture appropriately and according to the national regulations in accordance with the EC Low Voltage Directive 2006 95 EC and the EC Directive 2004 108 EC about ele...

Страница 20: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Отзывы: